header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 33 - 33
1 Apr 2019
Kato M Warashina H
Full Access

Purpose

Leg length discrepancy after total hip arthroplasty (THA) sometimes causes significant patient dissatisfaction. In consideration of the leg length after THA, leg length discrepancy is often measured using anteroposterior (AP) pelvic radiography. However, some cases have discrepancies in femoral and tibial lengths, and we believe that in some cases, true leg length differences should be taken into consideration in total leg length measurement. We report the lengths of the lower limb, femur, and tibia measured using the preoperative standing AP full-leg radiographs of the patients who underwent THA.

Materials and methods

From August 2013 to February 2017, 282 patients underwent standing AP full-leg radiography before THA. Of the patients, 33 were male and 249 were female. The mean age of the patients was 65.7±9.4 years. We measured the distances between the center of the tibial plafond and lesser trochanter apex (A-L), between the femoral intercondylar notch and lesser trochanter (K-L), and between the centers of the tibial plafond and intercondylar spine of the tibia (A-K) on standing AP full-leg radiographs before THA operation. We examined the differences in leg length and the causes of these discrepancies after guiding the difference between them.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 51 - 51
1 Feb 2017
Kato M Warashina H
Full Access

Background

We occasionally come across cortical atrophy of the femur with cemented collarless polished triple-taper stem, a short time after the operation. This study aimed to estimate the radiographs of cemented collarless polished triple-taper stem taken at three, six, twelve, and twenty-four months after the initial operation.

Methods

Between May 2009 and April 2011, 97 consecutive patients underwent primary total hip arthroplasty and hemiarthroplasty using a SC-stem or C-stem implant. During the 24 month follow-up, radiographic examination was performed on a total of 95 patients (98 hips). Out of those 95 patients, 52 hips had total hip arthroplasty, 45 had osteoarthritis, 5 had idiopathic osteonecrosis, there were two 2 other cases and 46 hips had hemiarthroplasty for femoral neck fractures. The cementing grade was estimated on the postoperative radiographs. The 24 month postoperative radiographs were analyzed for changes in stem subsidence, cortical atrophy and cortical hypertrophy. According to the Gruen zone, cortical atrophy and cortical hypertrophy were classified on the femoral side. We defined no cortical atrophy as grade 0, cortical atrophy less than 1 mm as grade 1, more than 1 mm and less than 2 mm as grade 2, and more than 2 mm as grade 3. We defined Grade 1 as 1 point, Grade 2 as 2 points, and Grade 3 as 3 points. The points in every zone were calculated, and the average per zone was determined.