Purpose: The original C-STEM (DePuy, Warsaw, IN, USA), a triple tapered polished collarless cemented stem, has an established clinical record. The new C-stem-AMT retains the identical intramedullary design, but enhances the extramedullary portion of the stem with a high offset option, and a mini-taper which is fully covered by the head, and accommodates a broad range of head diameters and neck lengths. This is an early report of clinical experience with the C-STEM AMT.
Methods: From March 2005 to June 2006, 34 C-STEMAMTs were implanted in 32 patients (21 females, 13 males) with mean age of 69 years (R 52–89). Diagnoses were Osteoarthritis in 30, AVN in 2, DDH in 1, and loose femoral implant in 1. Average follow-up was 9.7 months (R 3–18).
Preoperative and postoperative Harris Hip Scores, radiographs, and postoperative complications were recorded prospectively and compared to an early cohort of 66
C-Stems previously implanted between May 1999 and July 2001.
Results: Harris Hip Scores improved from 38 to 99 at one year. There has been no loosening, significant subsidence or reoperations. No dislocations have occurred, in contrast to 6 (9%) dislocations in the original C-Stem group.
Conclusions: As expected, the behaviour of the intramedullary portion of the C-Stem AMT is mirroring the experience with the C-Stem. The enhanced extramedullary design which accommodates additional neck lengths and head sizes, improves range of motion and provides additional offset has substantially reduced dislocation by facilitating accurate reconstruction of appropriate hip biomechanics.