header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Trauma

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 10 - 10
1 Nov 2016
Scott C Oliver W MacDonald D Wade F Moran M Breusch S
Full Access

Risk of revision following total knee replacement is relatively high in patients under 55 years of age, but little is reported regarding non-revision outcomes. This study aims to identify predictors of dissatisfaction following TKR in patients younger than 55 years of age.

We assessed 177 TKRs (157 consecutive patients) from 2008 to 2013. Data was collected on age, sex, implant, indication, BMI, social deprivation, range of motion, and prior knee surgery in addition to Oxford Knee Score (OKS) and SF-12 score. Postoperative data included knee range of motion, complications, and OKS, SF-12 score and satisfaction measures at one year.

Overall, 24.9% of patients (44/177) were unsure or dissatisfied with their TKR. Significant predictors of dissatisfaction on univariable analysis (p<0.05) included: Kellgren-Lawrence grade 1/2 osteoarthritis; indication; poor preoperative OKS; postoperative complications; and poor improvements in OKS and pain component score (PCS) of the SF-12. Odds ratios for dissatisfaction by indication compared to primary OA: OA with previous meniscectomy 2.86; OA in multiply operated knee 2.94; OA with other knee surgery 1.7; OA with BMI>40kgm-2 2; OA post-fracture 3.3; and inflammatory arthropathy 0.23. Multivariable analysis showed poor preoperative OKS, poor improvement in OKS and postoperative stiffness, particularly flexion of <90°, independently predicted dissatisfaction (p<0.005).

Patients coming to TKR when under 55 years of age differ from the ‘average’ arthroplasty population, often having complex knee histories and indications for surgery, and an elevated risk of dissatisfaction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 10 - 10
1 Jun 2016
Scott C Eaton M Nutton R Wade F Evans S Pankaj P
Full Access

25–40% of unicompartmental knee replacement (UKR) revisions are performed for unexplained pain possibly secondary to elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on cancellous bone strain in a finite element model (FEM) of a cemented fixed bearing medial UKR, validated using previously published acoustic emission data (AE).

FEMs of composite tibiae implanted with an all-polyethylene tibial component (AP) and a metal backed one (MB) were created. Polyethylene of thickness 6–10mm in 2mm increments was loaded to a medial load of 2500N. The volume of cancellous bone exposed to <−3000 (pathological overloading) and <−7000 (failure limit) minimum principal (compressive) microstrain (µ∊) and >3000 and >7000 maximum principal (tensile) microstrain was measured.

Linear regression analysis showed good correlation between measured AE hits and volume of cancellous bone elements with compressive strain <−3000µ∊: correlation coefficients (R= 0.947, R2 = 0.847), standard error of the estimate (12.6 AE hits) and percentage error (12.5%) (p<0.001). AP implants displayed greater cancellous bone strains than MB implants for all strain variables at all loads. Patterns of strain differed between implants: MB concentrations at the lateral edge; AP concentrations at the keel, peg and at the region of load application. AP implants had 2.2 (10mm) to 3.2 (6mm) times the volume of cancellous bone compressively strained <−7000µ∊ than the MB implants. Altering MB polyethylene insert thickness had no effect. We advocate using caution with all-polyethylene UKR implants especially in large or active patients where loads are higher.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 8 - 8
1 Sep 2013
Scott C Eaton M Nutton R Wade F Pankaj P Evans S
Full Access

Joint registries report that 25–40% of UKR revisions are performed for pain. Proximal tibial strain and microdamage are possible causes of this “unexplained” pain. The aim of this study was to examine the effect of UKR implant design and material on proximal tibial cortical strain and cancellous microdamage.

Composite Sawbone tibias were implanted with cemented UKR components: 5 fixed bearing all-polyethylene (FB-AP), 5 fixed bearing metal backed (FB-MB), and 5 mobile bearing metal backed implants (MB-MB). Five intact tibias were used as controls. Tibias were loaded in 500N increments to 2500N. Cortical surface strain was measured using digital image correlation (DIC). Cancellous microdamage was measured using acoustic emission (AE), a technique which detects elastic waves produced by the rapid release of energy during microdamage events.

DIC showed significant differences in anteromedial cortical strain between implants at 1500N and 2500N in the proximal 10mm only (p<0.001) with strain shielding in metal backed implants. AE showed significant differences in cancellous microdamage (AE hits), between implants at all loads (p=0.001). FB-AP implants displayed significantly more hits at all loads than both controls and metal backed implants (p<0.001). FB-AP implants also differed significantly by displaying AE hits on unloading (p=0.01), reflecting a lack of implant stiffness. Compared to controls, the FB-AP implant displayed 15x the total AE hits, the FB-MB 6x and the MB-MB 2.7x. All-polyethylene medial UKR implants are associated with greater cancellous bone microdamage than metal backed implants even at low loads.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 6 - 6
1 Feb 2013
Akhtar M Wade F
Full Access

Charlson Index has been found to predict functional outcome, implant survival, mortality, length of hospital stay and resource use after arthroplasty. Obesity can influence the outcome following lower limb arthroplasty. Our aim was to identify if there was a relationship between Charlson index, obesity and disability and whether this relationship had altered in recent years.

Demographic details, Charlson index, BMI, SF-12 and oxford score were recorded prospectively for 88 consecutive patients undergoing lower limb arthroplasty between August 2011 and January 2012(Group B). The results were compared with Charlson index of 92 consecutive patients between August 2005 and March 2006(Group A).

The mean age for Group A was 70 years (range 41–90). 56(61%) were female and 36(39%) male. The mean Carlson index was 3 (range 0–6) and median was 3. The mean age for Group B was 67 years (range 45–91). 53(60%) were female and 35(40%) male. The mean Charlson index was 2.2 (range 0–11) and median was 0. The difference between the groups was statistically significant with a P value of 0.001. The mean BMI for Group B was 31 (range 15–56) and median 30. Thirteen patients (15%) had BMI<25, 29 patients (33%) had BMI between 25–29. 9(Pre-Obese), 23 patients (26%) had BMI between 30–34. 9(Obese-Class 1), 10 patients (11%) had BMI between 35–39. 9(Obese-Class 2)and 13 patients (15%) had BMI>40 (Obese-Class 3). The only difference between group B1(BMI<30) and B2(BMI>30) was of age with a P value of 0.0003 (72 vs 59 years).

The current group had less comorbidity but 85% of patients were overweight or obese. These patients were younger but there was no difference in their health or disability before surgery. The high prevalence of obesity may represent treatment selection of these patients away from waiting list centres. Consideration about the treatment of obesity should be given before lower limb arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 170 - 170
1 Sep 2012
Scott C Bhattacharya R Macdonald D Wade F Nutton R
Full Access

Unicompartmental knee replacements (UKRs) have inconsistent and variable survivorships reported in the literature. It has been suggested that many are revised for ongoing pain with no other mode of failure identified. Using a medial UKR with an all-polyethylene non-congruent tibial component from 2004–7, we noted a revision rate of 9/98 cases (9.2%) at a mean of 39 months. Subchondral sclerosis was noted under the tibial component in 3/9 revisions with well fixed implants, and the aim of this study was to investigate this as a mode of failure. 89 UKRs in 77 patients were investigated radiographically (at mean 50 months) and with SF-12 and Oxford Knee scores at mean follow up 55 months. Subjectively 23/89 cases (25%) had sclerosis under the tibial component. We describe a method of quantifying this sclerosis as a greyscale ratio (GSR), which was significantly correlated with presence/absence of sclerosis (p<0.001). Significant predictors of elevated GSR (increasing sclerosis) were female sex (p<0.001) and elevated BMI (P=0.010) on both univariate and multivariate analysis. In turn, elevated GSR was significantly associated with poorer improvement in OKS (p<0.05) at the time of final follow up. We hypothesise that this sclerosis results from repetitive microfracture and adaptive remodelling in the proximal tibia due to increased strain. Finite element analysis is required to investigate this further, but we suggest caution should be employed when considering all polyethylene UKR implants in older women and in those with BMI >35.