Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_1 | Pages 1 - 1
23 Jan 2023
Cottam A Van Herwijnen B Davies EM
Full Access

We present a large single surgeon case series evaluation of a new growth guidance technique for the treatment of progressive early onset scoliosis (EOS). A traditional Luque trolley construct uses wires to hold growth guidance rods together. We describe a new technique that uses domino end to side connectors in place of the wires with the aim of providing a stronger construct to better limit curve progression, while allowing longitudinal growth.

We did a thorough retrospective review of patient records and radiological imaging. Sequential measurements of Cobb angle and length of rods were recorded, as well as any further surgical procedures and associated complications. This enabled us to quantify the ability of a technique to limit curve progression and simultaneously allow growth of the construct. In total, 28 patients with EOS (20 idiopathic, four syndromic, and four neuromuscular) have been treated with this technique, 25 of whom have a minimum follow-up of 2 years and 13 have a minimum follow-up of 5 years.

The average correction of the preoperative Cobb angle was 48.9%. At the 2-year follow up, the average loss of this initial correction was 15 degrees, rising to only 20 degrees at a minimum of 5 years (including four patients with a follow-up of 8 years or more). The growth of the constructs was limited. The average growth at 2 years was 3.7 mm, rising to 19 mm at the 5-year follow-up.

Patients who underwent surgery with this technique before the age of 8 years seemed to do better. This group had a revision rate of only 18% at an average time of 7 years after the index procedure, and the average growth was 22 mm. However, the group that had index surgery after the age of 8 years had a 64% revision rate at an average of 3.2 years after surgery and an average growth of only 11.6 mm. Overall, in the cases series, there were four hardware failures (14%) and one deep infection (3.5%), and only ten patients (36%) had one extra surgery after the index procedure. Only two of the 13 patients who are at a follow-up of 5 years or more have had revision.

This modified Luque trolley technique has a good capacity for initial curve correction and for limiting further curve progression, with limited longitudinal growth before 2 years and improved growth thereafter. This technique might not be so useful after the age of 8 years because of poor growth and a higher early revision rate. We have also demonstrated a low cost technique with a low hardware failure rate that saves many future surgeries for the patient compared with other techniques used in the treatment of EOS.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_10 | Pages 3 - 3
1 Oct 2019
Rustenburg C Emanuel K Holewijn R van Royen B Smit T
Full Access

Purpose of study and background

Clinical researchers use Pfirrmann classification for grading intervertebral disc degeneration radiologically. Basic researchers have access to morphology and instead use the Thompson score. The aim of this study was to assess the inter-observer reliability of both classifications, along with their correlation.

Methods and Results

We obtained T2-weighted MR images of 80 human lumbar intervertebral discs with various stages of degeneration to assess the Pfirrmann-score. Then the discs were dissected midsagittally to obtain the Thompson-score. The observers were typical users of both grading systems: a spine surgeon, radiology resident, orthopaedic resident, and a basic scientist, all experts on intervertebral disc degeneration. Cohen's kappa (CK) was used to determine inter-observer reliability, and intra-class correlation (ICC) as a measure for the variation between the outcomes.

For the Thompson score, the average CK was 0.366 and ICC score 0.873. The average inter-observer reliability for the Pfirrmann score was 0.214 (CK) and 0.790 (ICC). Comparing the grading systems, the intra-observer agreement was 0.240 (CK) and 0.685 (ICC).