header advert
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 11 - 11
1 Aug 2021
Lukic J Rajeev A Tyas B Singisetti K
Full Access

Hip fractures in elderly patients are managed at both major trauma centers (MTC) and trauma units (TU). Previous evidence has demonstrated the importance of early surgery to reduce the morbidity and mortality related to the injury. The aim of this study is to compare the ‘time to theatre' and ‘30 day mortality' in TUs versus MTC in UK.

A retrospective review of prospectively collected data on NHFD was performed. The average ‘time to theatre' in hours and ‘30 day mortality' of all hospitals were analysed between January and December 2018. Further subgroup analysis was done to check for any regional variations; in each instance a Shapiro-Wilk test was used to check for normal distribution, followed by a one-way ANOVA with a Tukey's post hoc test.

Data from 158 hospitals in England (ENG), Wales (WAL) and Northern Ireland (NI) were used; 18 of which were MTC. There were 57,936 operative cases in TUs and 8606 in MTC's. The mean time (hours) to surgery from presentation was 32.51 and 32.64 for TUs and MTC respectively (p=0.513).

There was no significant difference in ‘30 day mortality' (p=0.635) between TUs (6%) and 5.7% MTC's (5.7%), MTC's and TUs in ENG, WAL and NI (p=0.555), and MTC and WAL, NI and the different regions of ENG (p=0.209).

A significant difference was observed, between the regional practice for TUs versus MTC's in ENG, WAL and NI (p=0.001) and between MTC's and TUs in WAL, NI and the different regions of ENG (p=0.001), with patients waiting significantly longer in NI for their procedure (mean=60.25 hours, p=0.001)

There was no significant difference in time to surgery or 30 day mortality between TUs and MTC's, demonstrating comparable hip fracture care, despite MTCs need to prioritise more serious injuries.