Both from experimental studies and the large arthroplasty registries there is evidence that bacteria are more often involved in implant loosening then is currently reported. To further elucidate this potential problem, the current study investigated the hypothesis that many total hip arthroplasty revisions, classified as aseptic, are in fact low-grade infections missed with routine diagnostics. In 7 Dutch hospitals, 176 patients with the preoperative diagnosis of aseptic loosening of their total hip arthroplasty were enrolled. From each patient, the preoperative history was obtained. During surgery, between 14 and 20 tissue samples were obtained for routine culture, pathology analysis and broad range 16S rRNA PCR with reverse line blot hybridization (PCR-RLB). Samples were taken from the (neo-) capsule and acetabular and femoral interface tissue. Cultures were performed locally according to similar protocols. One specialized pathologist, blinded for all other results, analyzed all pathology samples. The PCR-RLB analysis was performed centrally, using a technique previously validated for orthopedic use. Patients were classified as not infected, suspect for infection or infected, according to strict, predefined criteria. Each patient had a follow-up visit after 1 year.Background
Methods
Although bovine carriers of antibiotics are generally accepted in the treatment of local infections, a literature search in PubMed, Medline and Embase up to April 2006 did not reveal any information on the human pharmacokinetics on Garacol®, a bovine carrier containing the equivalent of 130 mg gentamicin sulphate, on the market since 1995. The purpose of this study was to describe the human in vivo pharmacokinetics of Garacol®. A cohort of 19 consecutive patients with an acute periprosthetic infection to which 2 to 5 fleeces were applied in each case. Initially, the concentration in blood increased to 3.2–7.2 mg/L depending on the number of fleeces that were applied. The serum peak concentrations resulted in peak/MIC ratios of 2.5–36 for P. aeruginosa, S. aureus and Klebsiella spp. Peak gentamicin levels in the exudate are bactericidal for several days, even for gentamicin-resistant micro-organisms. Subsequently, the serum values decreased almost linearly below 0.3 mg/L in 18 to 62 hours. After 24 hours the gentamicin serum levels dropped below the threshold for toxicity of 2 mg/L. Comparison is made between the difference in pharmacokinetic behaviour of the Garacol® drug with Septocoll® and conventional and mini PMMA beads. The conclusion is that collagen-loaded fleeces may be useful as an adjuvant treatment of implant-related infections.
From Mars 1997 till July 2003 we subsequent included 32 patients, 26 with a minimal follow-up of 2 years are presented in this study. We evaluated the results of the treatment prospectively. The inflammatory parameters; C-reactive protein, erythrocyte sedimentation rate and white blood cell count (before and after debridement) The Harris Hip Score and radiograms were monitored multiple times.
In 23 patients the infection did not re-appear. The C-reactive protein normalised from a mean of 103 (2–320) to lower than 5 at 2 years, the erythrocyte sedimentation rate from 72 (14–120) to lower than 10. The white blood cell count was not elevated. In none of the cases radiological signs of loosening was found and the mean HHS was 88 (75–96) points. However in 3 patients the infection did re-occur: once after 2.5 months with the same bacterium as the first infection, a Streptococcus, again treated with a surgical debridement. At present she is clinical free of infection at a follow up of 2 years. The 2 other re-infections occurred respectively after 9 and 10 months, once after a surgical treatment of a jaw abscess and once after an episode of diverticulitis. The cultures derived other bacteria, a streptococcus and an E. coli, than the first infection, both a Staphylococcus aureus. In both cases a two-stage revision was the choice of treatment.
We reviewed 61 elbow synovectomies in 50 patients with rheumatoid arthritis, with follow-up varying from 4 to 10 years (mean 6.5 years). The results were graded as satisfactory in 70%, with no significant difference in the results between joints which were radiologically good before operation and those which had been destroyed. Longer term results were analysed of 27 elbow synovectomies in 22 patients followed up for over six years. The results were satisfactory in 67% of the patients in both 1981 and in 1987, with no deterioration over this period.