header advert
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 2 - 2
17 Jun 2024
Fishley W Morrison R Baldock T Hilley A Baker P Townshend D
Full Access

Background

In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods.

Method

The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1st January 2019 and 31st December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 18 - 18
10 Jun 2024
Haston S Langton D Townshend D Bhalekar R Joyce T
Full Access

Despite advancements, revision rates following total ankle replacement (TAR) are high in comparison to other total joint replacements. This explant analysis study aimed to investigate whether there was appreciable metal particulate debris release from various contemporary TARs by describing patterns of material loss. Twenty-eight explanted TARs (9 designs: 3 fixed and 6 mobile bearing), revised for any reason, were studied. The articulating surfaces of the metal tibial and talar components as well as the polyethylene insert were assessed for damage features using light microscopy. Based on the results of the microscopic analysis, scanning electron microscopy with energy dispersive X-ray spectroscopy was performed to determine the composition of embedded debris identified, as well as non-contacting 3D profilometry. Pitting, indicative of material loss, was identified on the articulating surfaces of 54% of tibial components and 96% of talar components. Bearing constraint was not found to be a factor, with similar proportions of fixed and mobile bearing metal components showing pitting. More cobalt-chromium than titanium alloy tibial components exhibited pitting (63% versus 20%). Significantly higher average surface roughness (Sa) values were measured for pitted areas in comparison to unpitted areas of these metal components (p<0.05). Additionally, metallic embedded debris (cobalt-chromium likely due to pitting of the tibial and talar components or titanium likely from loss of their porous coatings) was identified in 18% of polyethylene inserts. The presence of hard 3rd body particles was also indicated by macroscopically visible sliding plane scratching, identified on 79% of talar components. This explant analysis study demonstrates that metal debris is released from the articulating surfaces and the coatings of various contemporary TARs, both fixed and mobile bearing. These findings suggest that metal debris release in TARs may be an under-recognised issue that should be considered in the study of painful or failed TAR moving forwards.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 14 - 14
4 Jun 2024
Liaw F O'Connor H McLaughlin N Townshend D
Full Access

Introduction

Following publication of the Ankle Injury Management (AIM) trial in 2016 which compared the management of ankle fractures with open reduction and internal fixation (ORIF) versus closed contact casting (CCC), we looked at how the results of this study have been adopted into practice in a trauma unit in the United Kingdom.

Methods

Institutional approval granted to identify eligible patients from a trauma database. 143 patients over 60 years with an unstable ankle fracture between 2017 and 2019 (1 year following publication of the AIM trial) were included. Open fractures, and patients with insulin-dependent diabetes or peripheral vessel disease were excluded (as per AIM criteria). Radiographs were reviewed for malunion and non-union. Clinical notes were reviewed for adverse events. Minimum follow up was 24 months.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction

This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales.

Methods

Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 19 - 19
4 Jun 2024
Critchley R Dismore L Swainston K Townshend D Coorsh J Kakwani R Murty A
Full Access

Background

Surgical intervention for hallux valgus and hallux rigidus is an option for patients presenting with severe pain and deformity. Literature suggest that patients with high Pain Catastrophisation Scores (PCS) have poorer outcomes in spinal and to a lesser extent in arthroplasty surgery. There is however very little evidence pertaining to foot and ankle surgery.

Aim

We aimed to study whether catastrophisation as measured by PCS influenced the outcomes following surgery for Hallux valgus and rigidus.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 15 - 15
16 May 2024
Egglestone A Kakwani R Murty A Townshend D
Full Access

Introduction

When ankle arthroplasty fails the options are revision to arthrodesis or revision to arthroplasty. We report early outcomes of revision procedures for failed total replacement.

Methods

Retrospective review of prospectively collected data including post-operative complications, union, survivorship and PROMS scores to compare revision to arthrodesis and revision to arthroplasty.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 19 - 19
16 May 2024
Clifton L Kingman A Rushton P Murty A Kakwani R Coorsh J Townshend D
Full Access

Introduction

We report the functional outcome and survivorship of the Hintegra Total Ankle Replacement (TAR), in consecutive cases by multiple surgeons in a single UK institution. Between 2010–2014 the Hintegra TAR held 7.1% UK market share and surgeons should be aware of failure mechanisms.

Methods

We conducted a retrospective review of prospectively collected data for 70 consecutive Hintegra TAR cases in a single institution between 2010–2014. Data collected included patient demographics, complications, reoperations, patient reported outcome measures (PROMS: AOS, MOX-FQ, pain VAS) and patient satisfaction.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 12 - 12
16 May 2024
Tweedie B Townshend D Coorsh J Murty A Kakwani R
Full Access

Lateral approach open calcaneal osteotomy is the described gold standard procedure in the management of hindfoot deformity. With development of minimally invasive surgery, a MIS approach has been described, citing fewer wound complications and lower risk of sural nerve injury. This audit compares MIS to the traditional procedure. A retrospective review of all patients undergoing calcaneal osteotomy in Northumbria Trust in the past 5 years was performed. A total of 105 osteotomies were performed in 97 patients; 28 (13M:15F) in MIS group and 77 (40M:37F) had an open approach. The average age was 52.1 (range 16–83) for MIS and 51.5 (range 18–83) in the open group. All patients were followed up for development of wound complication, nerve injury and fusion rate. Wound complications were similar (10.7% in MIS group vs 10.3% in Open group) with no significant difference (p=0.48). Patients were treated for infection in 3(3.8%) cases in the open group and 2(7.1%) in the MIS group. This difference was not significant (p=0.43). 4 (14.3%) patients in the MIS group had evidence of sural nerve dysfunction post-operatively (managed expectantly), compared to 12(15.5%) patients in the open group (p=0.44). Of these, 2 went on to undergo neuroma exploration. There was no difference in nerve dysfunction in varus or valgus correction. Mean translation in the open group was measured as 7.3mm(SD=1.91;3 to 13mm) and 7.5mm(SD=1.25;5 to 10mm) in the MIS group. Translation was similar in varus or valgus correction. Non-union occurred in 2 patients in the MIS group and none in the open group (p= 0.06). MIS calcaneal osteotomy is a safe technique, that works as effectively as osteotomy performed through an open approach. There were lower rates of nerve injury, wound complication and infection, but this was not significantly different comparing groups. There was a higher risk of non-union in MIS technique.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 22 - 22
16 May 2024
Drake B Blundell M Gibson B Kingman A Kakwani R Townshend D
Full Access

Introduction

Day Case Surgery (defined as same day discharge) is a priority within the National Health Service and has been shown to provide beneficial outcomes for patients and hospitals. We report our experience developing a Day Case Programme for Total Ankle Replacement (TAR).

Methods

Prior to the introduction of a Day Case Programme, average length of stay following TAR in our unit was 3.5 days. Stakeholders were consulted about ways in which same day discharge could be facilitated. Patients' post-operative pain charts were reviewed prior to the introduction of this programme. Inclusion criteria included non-complex surgery (anticipated tourniquet < 2hrs), friend or relative support and pre-operative walking-aid assessment. An enhanced recovery protocol included long-acting popliteal block and dexamethasone. Patients were discharged with opiate analgesia and written pain instructions. Patients were asked to complete a pain and satisfaction questionnaire. Patient Reported Outcome Measures (PROMs) were recorded.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 21 - 21
16 May 2024
Morrell R Abas S Kakwani R Townshend D
Full Access

Background

The use of a knotless TightRope for the stabilisation of a syndesmotic injury is a well-recognised mode of fixation. It has been described that the device can be inserted using a “closed” technique. This presents a risk of saphenous nerve entrapment and post-operative pain.

Aim

We aimed to establish the actual risk of injury to the Saphenous Nerve using a “closed” technique for the insertion of a TightRope.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 22 - 22
8 May 2024
Brookes M Kakwani R Townshend D Murty A
Full Access

Background

Traditionally, the extended lateral approach (ELA) was the favoured approch for calcaneal fractures, but has been reported to have high incidence of wound complications. There has been a move amongst surgeons in the United Kingdom towards the sinus tarsi approach (STA) due to its minimally invasive nature, attempting to reduce such complications.

Aims

To evaluate outcomes of ELA and STA for all consecutive calcaneal fracture fixation in our institution over a 10yr period.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 23 - 23
1 Nov 2016
Johnson-Lynn S Cooney A Ferguson D Bunn D Gray W Coorsh J Kakwani R Townshend D
Full Access

Platelet rich plasma has been advocated for the treatment of plantar fasciitis but there are few good quality clinical trials to support its use. We report a pilot double blind randomised controlled trial of platelet rich plasma versus normal saline.

Methods

Patients with more than 6 months of MRI proven plantar fasciitis who had failed conservative management were invited to participate in this study. Patients were block randomised to either platelet rich plasma injection (intervention) or equivalent volume of normal saline (control). The techniques used for the injection and rehabilitation were standardised for both groups. The patient and independent assessor were blinded. Visual analogue scale for pain (VAS) and painDETECT were recorded pre-op and at 6 months.

Results

Twenty-eight patients (19 females, mean age 50 years) were recruited, with 14 randomised to each arm. At 6 month follow-up, 8 patients (28.6%) were lost to follow-up. There was a significant change in VAS score from baseline to follow-up in both intervention (mean change 37.2, p = 0.008) and control (mean change 42.2, p = 0.003) groups. However there was no difference between the arms in terms of the change in VAS score from baseline to follow-up (p = 0.183). There was no correlation between pre-op PainDETECT score and change in VAS.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 44 - 44
1 Sep 2012
Townshend D Ng P Wing K Penner M Younger A
Full Access

Introduction

Single photon emission computed tomography (SPECT) can be used to create a three dimensional image of a radiopharmaceutical bone scan. This combined with high resolution CT scan (SPECT-CT) with bone windows allows the linking of the information obtained in both investigations. The multiplanar anatomical information provided by CT is therefore linked with the functional, biological information of bone scintigraphy. The painful total ankle replacement has a number of potential causes of discomfort including impingement and loose components. Correct identification of the source of pain will assist surgeons in treating the source of the pain while avoiding unnecessary surgery. We present our experience of the use of SPECT-CT to investigate patients with ongoing pain following Total Ankle Replacement (TAR).

Materials and Methods

A retrospective analysis of all patients having SPECT-CT for continuing pain following TAR. Scans were requested in addition to plain radiographs, joint aspiration and blood testing. Results: A total of 12 patients were identified. The scan proved helpful in all cases. 5 patients showed increased uptake around one or both prostheses signifying loosening which was not apparent on plain films. Gutter impingement was identified in 4 patients. One patient had a talo-navicular non-union, one patient demonstrated sub-talar joint arthrosis and one patient showed no bony abnormality but soft tissue impingement at arthroscopy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 43 - 43
1 Sep 2012
Townshend D Penner M Younger A Glazebrook M Wing K
Full Access

Background

Ankle arthrodesis results in significantly improved pain and function for patients with end-stage ankle arthritis. Arthroscopic ankle arthrodesis has gained increasing popularity with reports of shorter hospital stays, time to union and equivalent union rates to open arthrodesis. However, there remains a lack of good quality prospective data.

Methods

We report a prospective comparative clinical study comparing open and arthroscopic ankle arthrodesis at two institutions with two-year follow-up. The primary outcome was the Ankle Osteoarthritis Scale and secondary outcomes included the SF-36, hospital stay and radiographic alignment. A power calculation was performed. There were 30 patients in each group.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 490 - 497
1 Apr 2011
Jameson SS Augustine A James P Serrano-Pedraza I Oliver K Townshend D Reed MR

Diagnostic and operative codes are routinely collected for every patient admitted to hospital in the English NHS. Data on post-operative complications following foot and ankle surgery have not previously been available in large numbers. Data on symptomatic venous thromboembolism events and mortality within 90 days were extracted for patients undergoing fixation of an ankle fracture, first metatarsal osteotomy, hindfoot fusions and total ankle replacement over a period of 42 months. For ankle fracture surgery (45 949 patients), the rates of deep-vein thrombosis (DVT), pulmonary embolism and mortality were 0.12%, 0.17% and 0.37%, respectively. For first metatarsal osteotomy (33 626 patients), DVT, pulmonary embolism and mortality rates were 0.01%, 0.02% and 0.04%, and for hindfoot fusions (7033 patients) the rates were 0.03%, 0.11% and 0.11%, respectively. The rate of pulmonary embolism in 1633 total ankle replacement patients was 0.06%, and there were no recorded DVTs and no deaths. Statistical analysis could only identify risk factors for venous thromboembolic events of increasing age and multiple comorbidities following fracture surgery.

Venous thromboembolism following foot and ankle surgery is extremely rare, but this subset of fracture patients is at a higher risk. However, there is no evidence that thromboprophylaxis reduces this risk, and these national data suggest that prophylaxis is not required in most of these patients.