Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 69 - 69
1 Jan 2016
Latham J Locker D Tilley S
Full Access

Aims

This retrospective study aimed to determine the causes of in-hospital death after Neck of Femur (NOF) fracture in Southampton General Hospital (SGH) over a 6 year period, comparing the clinical cause of death with findings at post-mortem. A previous study showed discrepancies between pre-mortem clinical diagnosis and autopsy findings after in-hospital deaths in SGH.

Methods

The study included all patients who died in SGH after NOF fracture from 2007–2013. Case notes were reviewed to determine the pre-mortem clinical diagnosis and compared with the autopsy findings to analyse major and minor discrepancies. Data were also analysed from the period 1997–2003 in order to compare the causes of death.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 19 - 19
1 Mar 2013
Bolland B Tilley S Tilley C Cook R Latham J
Full Access

Pseudotumour formation is being reported with increasing frequency in failing metal-on-metal hip resurfacings and replacements. This mode of failure complication has also been reported with metal-on-polyethylene bearing bearings when it is usually associated with evidence of surface corrosion and no apparent wear at the head–neck taper.

We present a case with evidence of taper wear and damage secondary to corrosion in an uncemented total hip replacement with a metal on polyethylene articulation (TMZF (Titanium, Molybdenum, Zirconium and Ferrous) Accolade® stem, Trident® HA coated acetabular shell, Low Friction Ion Treatment (LFIT™) Cobalt-Chrome anatomic head (40 mm), X3® polyethylene liner)

Case

A 69 year old woman had a THR in 2008. A year later she started to complain of lateral based hip pain. Clinical examination and initial imaging indicated trochanteric bursitis and heterotopic bone formation. The symptoms became worse over the next 3 years and the patient was listed for exploration and excision of heterotopic bone.

Surgical findings

Extensive pseudotumour was encountered deep to bursa and adherent to capsule. Abductors, external rotators and vastus lateralis were spared. There was minimal calcar osteolysis and marginal erosion in superior acetabulum. There was no obvious wear on the articulating surfaces of the femoral head and polyethylene inlay of the socket nor was there any evidence of neck-to-rim impingement or edge loading. There was visible blackening of both the taper and trunnion after femoral head removal.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 25 - 25
1 Sep 2012
Chana R Tilley S Facek M Walter W Zicat B Walter W
Full Access

Aim

Alumina ceramic on ceramic bearings in total hip arthroplasty (THA) may reduce the prevalence of osteolysis due to its properties of low wear and chemical inertness. This is critical in the younger patient population as they place increased demands over a longer period. This study reports on the clinical and radiographic outcomes of a series of modern cementless ceramic on ceramic THA at a minimum of 10 years in this younger group.

Method

A series of 120 consecutive third generation ceramic cementless THA were performed at a single centre in 110 patients from 1997 to 1999. The average age of the patients at the time of surgery was 45 years (20 to 55 years). All procedures were carried out via the posterior approach using the same implant by the two senior authors.