Traditionally, limb reconstruction physiotherapy consisted of face to face group rehabilitation. During the COVID-19 pandemic OP physiotherapy service provision was significantly reduced and delivery methods limited due to staff redeployment, service prioritisation and restriction of footfall within the hospital. A virtual exercise group for acute limb reconstruction patients was set up to maintain contact and clinical support. A small single centre study was performed over two 4 week periods capturing the experience of 35 patients. A patient reported questionnaire was used and revised post-pandemic to gather quantitative and qualitative data about the patients experience of the Limb Reconstruction Physiotherapy Service at each point in time. The qualitative data was analysed using an inductive thematic analysis.Introduction
Materials and Methods
Platelet-Rich Plasma (PRP), an autologous derivative of whole blood that contains a supraphysiological concentration of platelets and growth factors. Most published studies have investigated the effect of PRP-conditioned media on cell cultures. We are not aware of any study that has investigated whole PRP with its cellular components on human tissue cultures. This study aims to investigate the effect of PRP on cell migration from human Achilles tendon explants, and the subsequent cellular proliferative effects in culture. This is an Purpose
Methods
Total hip arthroplasty (THA) is regarded as one of the most successful surgeries in medicine. However, recent studies have revealed that ideal acetabular cup implantation is achieved less frequently than previously thought, as little as 50% of the time. It is well known that malalignment of the acetabular component in THA may result in dislocation, reduced range of motion, or accelerated wear. This study reports accuracy of a tactile robotic arm system to ream the acetabulum and impact an acetabulur cup compared to manual instrumentation. 12 fresh frozen cadaveric acetabulae were pre-operatively CT scanned and 3D templating was used to plan the center of rotation, and anteversion and inclination of the cup. Each specimen received THA, six prepared manually and six prepared with robotic arm guidance. Tactile, visual, and auditory feedback was provided through robotic guidance as well as navigated guided reaming and cup impaction. The robotic guidance constrained orientation of instruments thus constraining anteversion, inclination, and center of rotation for reaming, trialing, and final cup impaction. Post-operative CT scans were taken of each specimen to determine final cup placement for comparison to the pre-operative plans.INTRODUCTION
METHODS
Recent gains in knowledge reveal that the ideal acetabular cup position is in a narrower range than previously appreciated and that position is likely different based on femoral component anteversion. For that reason more accurate acetabular cup positioning techniques will be important for contemporary THA. It is well known that malalignment of the acetabular component in THA may result in dislocation, reduced range of motion or accelerated wear. Up to 8% of THA patients have cups malaligned in version by more than ±10° outside of the Lewinnek safe zone. This type of malalignment may result in dislocation of the femoral head and instability of the joint within the first year, requiring reoperation. Reported incidences of reoperation are 1-9% depending on surgical skills and technique. In addition, cup malalignment is becoming increasingly important as adoption of hard on hard bearings increases as the success of large head hard on hard bearings seems to be more sensitive to cup positioning. This study reports the accuracy of a haptic robotic system to ream the acetabulum and impact an acetabular cup compared to manual instrumentation. Six fresh frozen cadaveric acetabula were CT scanned and three-dimensional templating of the center of rotation, anteversion and inclination of the cup was determined pre-operatively. Half of the specimens were prepared with manual instrumentation while half were prepared with robotic guidance. Haptic and visual feedback were provided through robotics and an associated navigation system to guide reaming and impaction of the cup. The robot constrained the orientation and position of the instruments thus constraining the inclination, anteversion and center of rotation of the reamer, trial and the final cup. Post-operative CT's were used to determine the achieved cup placement and compared to the pre-operative plans.Introduction
Methods
Femoro-acetabular impingement (FAI) is a common source of impaired motion of the hip, often attributed to the presence of an aspherical femoral head. However, other types of femoral deformity, including posterior slip, retroversion, and neck enlargement, can also limit hip motion. This study was performed to establish whether the “cam” impinging femur has a single deformity of the head/neck junction or multiple abnormalities. Computer models of 71 femora (28 normal and 43 “cam” impinging) were prepared from CT scans. Morphologic parameters describing the dimensions of the head, neck, and medullary canal were calculated for each specimen. The anteversion angle, alpha angle of Notzli, beta angle of Beaulé, and normalized anterior heads offset were also calculated. Average dimensions were compared between the normal and impinging femora.Introduction
Materials and Methods