Osseointegrated Amputation Prostheses can be functionalised by both biological augmentation and structural augmentation. These augmentation techniques may aid the formation of a stable skin-implant interface. Current clinical options are limited in restoring function to amputees, and are associated with contact dermatitis and infection at the stump-socket interface. Osseointegrated Amputation Prosthesis attempts to solve issues at the stump-socket interface by directly transferring axial load to the prosthesis, via a skin-penetrating abutment. However, development is needed to achieve a seal at the skin-implant interface to limit infection. Fibronectin, an Extracellular Matrix protein, binds to integrins during wound healing, with the RGD tripeptide being part of the recognition sequence for its integrin binding domain. Summary
Introduction
Office seating includes a variety of chair styles. There is limited research investigating their effects on spinal angles. Investigate effects of active (Swopper and Vari-Kneeler), and static (Saddle and a Standard Office) chairs on lumbo-pelvic and cervical regions.Background
Purpose of Study
Prospective randomized intervention trial to determine whether patients undergoing rotating platform total knee arthroplasty have better clinical outcomes at two years when compared to patients receiving fixed bearing total knee arthroplasty as measured by the WOMAC, SF-36 and Knee Society (KSS) scores. 67 consecutive patients (33 males and 34 females; average age 66 years) were randomized into either receiving a DePuy Sigma rotating platform (RP) total knee arthroplasty (29 patients) or a DePuy Sigma fixed bearing (FB) total knee arthroplasty (38 patients). Inclusion criteria included patients between the ages of 45–75 undergoing single-sided total knee arthoplasty for clinically significant osteoarthritic degeneration. Pain, disability and well-being were assessed using the WOMAC, KSS, and SF-36 preoperatively and at 6 months, 1 year and 2 years post-operatively. In addition, intraoperative measures were collected. Pre-operative radiographs were analyzed using the Kellgren and Lawrence Score, modified Scotts Scoring and mechanical axis. Post-operative radiographs were collected at 1 and 2 years and analyzed to identify evidence of prosthetic loosening, implant positioning and limb alignment.Purpose
Method
Infection following total knee arthroplasty is a serious complication. Recently there has been increasing incidence of isolation of multi-drug resistant bacteria from peri-prosthetic infections. The aim of our study is to identify the organisms causing delayed deep infections following primary total knee arthroplasty in the current situation. We also compared the differences in outcome based on the infecting organism. We undertook a retrospective study of all the patients who presented with delayed deep infection following primary total knee replacement during a six year period between April 1998 and March 2004. Organisms were isolated in 27 of the 31 patients who presented with delayed deep infection. Forty-four % of the organisms isolated were multi-drug resistant with increasing incidence of Methicillin resistant Staphylococcus aureus and multi-drug resistant Staphylococcus epidermidis infections. Successful outcome following an infected total knee arthroplasty was lower compared to the previous studies where there were fewer multi-drug resistant organisms. The average number of surgical procedures carried out was significantly higher when the organism isolated was multi-drug resistant. The number of patients with satisfactory outcome is significantly lower when the organism isolated is multi-drug resistant.
The aim of our study is to identify the organisms causing delayed deep infections following primary total knee arthroplasty in the current situation. We also compared the differences in outcome based on the infecting organism. We undertook a retrospective study of all the patients who presented with delayed deep infection following primary total knee replacement during a six year period between April 1998 and March 2004. We analysed the infecting organism, sensitivity of the organism to antibiotics, number of surgical procedure carried out and the outcome of the infected arthroplasty based on the infecting organism. Statistical analysis was done using Fisher’s Exact test for categorical data and Mann-Whitney U test for the non-parametric numeric data. The mean age at the time of primary arthroplasty was 69.9 years (range 46 to 92 years, SD=10.8). The mean follow-up (time since the initial knee replacement) was 77.3 months (range 27–170 months,). The mean follow-up since the last surgical procedure to treat infection was 31 months (range 14–47 months). Organisms were isolated in 27 of the 31 patients who presented with delayed deep infection. Forty-four % of the organisms isolated were multi-drug resistant with increasing incidence of Methicillin resistant Staphylococcus aureus and multi-drug resistant Staphylococcus epidermidis infections. Successful outcome following an infected total knee arthroplasty was lower compared to the previous studies where there were fewer multi-drug resistant organisms. The number of patients with satisfactory outcome is significantly lower when the organism isolated is multi-drug resistant. Patients infected by multi-drug resistant organisms undergo higher number of surgical procedures compared to patients where the organism is not multi-drug resistant. We conclude that deep infection with MRSA and Methicillin resistant Staphylococcus epidermidis are on the rise. Outcome is significantly better when the organism isolated is non resistant Staphylococcus aureus.
All patients underwent an initial application of Orthofix external fixator with pins in the proximal and middle phalanx. The patients were advised to gradually distract the device 3-4 times a day, for two weeks. They were then brought back for removal of fixator and partial fasciectomy with closure of skin by V-Y plasty. The results were assessed in thirteen patients, as two were lost to follow-up. The mean follow-up period was 30 months (6 – 64 months). The total mean preopera-tive extension deficit improved from 130 degrees to 38 degrees postop.; PIP joint deformity improved from a mean of 77 degrees to 33 degrees postop. and the mean TRAM (Total range of active movements) improved from 108 degrees to 165 degrees. Functional assessment was done using Michigan Hand Outcome Questionnaire. Overall improvement in hand function was from a preoperative 34% to a postoperative 89%.; aesthetic improvement from a preop. of 46% to a postop of 81% and pain improvement from a preop of 66% to a postop of 96%. One patient had recurrence, one had features of RSD (Reflex Sympathetic Dystrophy) and one had to undergo amputation due to poor tolerance and persistent infection.
We reviewed 13 patients with a complex fracture-dislocation of the proximal interphalangeal joint of a finger and one patient with a complex fracture-dislocation of the interphalangeal joint of thumb. We had treated these injuries using a pins and rubbers traction system which had been modified to avoid friction of the pins against the bone during mobilisation of the joint in order to minimise the risk of osteolysis. A Michigan hand outcome questionnaire was used for subjective assessment. The active range of movement (AROM) of the proximal and distal interphalangeal joints and the grip strength were used for objective assessment. The mean follow-up was 34 months (12 to 49). The mean normalised Michigan hand outcome score was 84. The mean AROM of the proximal interphalangeal joint was 85° and that of the distal interphalangeal joint 48°. The mean grip strength was 92% of the uninvolved hand. Twelve patients have returned to their original occupations. There has been no radiological osteolysis or clinical osteomyelitis. This modified traction system has given acceptable results with a low rate of complications. It is light, cheap, effective and easy to apply.
Ten patients, who underwent treatment for complex fracture-dislocation of the proximal interphalangeal joint of finger and one patient for that of the interphalangeal joint of thumb with a modified pins and rubbers traction system, were reviewed to evaluate the clinical and functional results. Two patients had open fracture-dislocation, 5 had pilon fractures and 4 had fracture-dislocations. The system was modified to avoid rotation of the pins in the bone during joint mobilization, thus minimizing the risk of osteolysis due to friction of pins over the bone. Michigan hand scoring system was used for subjective assessment and range of motion at proximal and distal interphalangeal joints and grip strength for objective assessment. Average follow-up was 18 months (range 3 months to 28 months). The average normalised Michigan hand score was 86. Based on Michigan scores, overall hand function was rated excellent in 8 patients, good in 2 and poor in 1. Eight patients have returned to their original jobs. The average arc of flexion in the proximal interphalangeal joint was 85 degrees and in the distal interphalangeal joint it was 47 degrees. The average grip strength was 95 percent of the uninvolved side. Two patients developed minor pin site infection, which did not necessitate pin removal or any alteration in the treatment regime. There have been no cases of osteolysis, osteitis or osteomyelitis. This modification of pins and rubbers traction system has given very acceptable results with a low complication rate. It is light, cheap, effective and easy to apply.