header advert
Results 1 - 11 of 11
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 13 - 13
1 Feb 2020
Tanaka S Tei K Minoda M Matsuda S Takayama K Matsumoto T Kuroda R
Full Access

Introduction

Acquiring adaptive soft-tissue balance is one of the most important factors in total knee arthroplasty (TKA). However, there have been few reports regarding to alteration of tolerability of varus/valgus stress between before and after TKA. In particular, there is no enough data about mid-flexion stability. Based on these backgrounds, it is hypothesized that alteration of varus/valgus tolerance may influence post-operative results in TKA. The purpose of this study is an investigation of in vivo kinematic analyses of tolerability of varus/valgus stress before and after TKA, comparing to clinical results.

Materials and Methods

A hundred knees of 88 consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. The kinematic parameters of the soft-tissue balance, and amount of coronal relative movement between femur and tibia were obtained by interpreting kinematics, which display graphs throughout the range of motion (ROM) in the navigation system. Femoro-tibial alignments were recorded under the stress of varus and valgus before the procedure and after implantation of all components. In each ROM (0, 30, 60, 90, 120 degrees), the data of coronal relative movement between femur and tibia (tolerability) were analyzed before and after implantation. Furthermore, correlations between tolerability of varus/valgus and clinical improvement revealed by ROM and Knee society score (KSS) were analyzed by logistic regression analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 48 - 48
1 Mar 2017
Tei K Minoda M Shimizu T Matsuda S Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed and widely used. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femoro-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femoro-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system and tensor device intra-operatively in TKA.

Materials and Methods

Sixty-one consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. During surgery, using a tensor device, after bony cut of femur and tibia, joint gaps were assessed in 0 and 90 degrees in flexion. Then, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal and sagittal relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) in the navigation system. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with a ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p< 0.05).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 76 - 76
1 May 2016
Tei K Kihara S Shimizu T Matsumoto T Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femolo-tibial joint as well as posterior-stabilized (PS) polyethylene insert, even if PCL is sacrificed after TKA. The purpose of this study is an investigation of in vivo kinematics of femolo-tibial joint with use of CS polyethylene insert before and after PCL resction using computer assisted navigation system intra-operatively in TKA.

Materials and Methods

Twenty-four consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker) were performed using computer assisted navigation system. In all patients, difference between extension and flexion gap was under 3mm after bony cut of femur and tibia. During surgery, CS polyethylene tibial trial insert were inserted after trial implantation of femoral and tibial components, before and after resection of PCL, respectively. The kinematic parameters of the soft-tissue balance, and amount of coronal (valgus/varus), sagittal (anterior/posterior) and rotational relative movement between femur and tibia were obtained by interpreting kinematics, which display tables throughout the range of motion (ROM) (Figure1). During record of kinematics, the surgeon gently lifted the experimental thigh three times, flexing the hip and knee. In each ROM (30, 45, 60, 90, max degrees), the data were analyzed with paired t-test, and an ANOVA test, and mean values were compared by the multiple comparison test (Turkey HSD test) (p < 0.05).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 48 - 48
1 Jan 2016
Takayama K Matsumoto T Muratsu H Nakano N Shibanuma N Tei K Matsushita T Kuroda R Kurosaka M
Full Access

Purpose

The tibia first technique in unicompartmental knee arthroplasty (UKA) may have the advantage that surgeons can obtain a balanced flexion-extension gap. However, changes of the soft tissue tension during UKA has not been elucidated yet. The purpose of this study was to examine the correlation between the soft tissue tension before the femoral osteotomy and after the femoral component in place using the tensor in UKA.

Methods

Thirty UKAs for isolated medial compartmental osteoarthritis or idiopathic osteonecrosis were assessed. The mean age was 71.8±8.5 years old (range: 58–85), and the average coronal plane femorotibial angle (FTA) was 181.2±3.2 degree preoperatively. All the patients received a conventional medial Zimmer Unicompartmental High Flex Knee System (Zimmer Inc, Warsaw, Ind). The actual values of the proximal and posterior femoral osteotomy were calculated by adding the thickness of the bone saw blades to the thickness of the bony cut. Using a UKA tensor which designed to facilitate intra-operative soft tissue tension throughout the range of motion (ROM), the original gap before the femoral osteotomy, the component gap after the femoral osteotomy, and component placement were assessed under 20 lb distraction forces. (Figure 1)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 521 - 521
1 Dec 2013
Sasaki H Ishida K Tei K Shibanuma N Matsumoto T Kuroda Y Oka S Matsuzaki T Uefuji A Tateishi H Kuroda R Kurosaka M
Full Access

Introduction

Increased long-term survival of TKA is becoming more important. Several studies have confirmed that optimal positioning and alignment of prosthetic components is crucial for the best long-term results. Therefore, the purpose of the current study was to compare the postoperative alignment and sizing of femoral prosthesis among patients performed by 3 different navigation systems.

Methods

Twenty patients who underwent primary TKA (E. motion; B. Braun Aesculap, Tuttlingen, Germany) using a CT-free navigation system (OrthoPilot v 4.2) by modified gap technique were enrolled in this study. The results of this study group were retrospectively compared with those in a control group of 20 matched-paired posterior stabilized TKAs (Triathlon;Stryker; Mahwah, NJ, USA) which were using another CT-free navigation system (Stryker Navigation System) by measured technique and 20 matched-paired posterior stabilized TKAs (Press-fit Condylar prosthesis; DePuy, Tokyo, Japan) using CT-based navigation system (VectorVision) by measured technique. Several parameters were evaluated for each patient using Athena Knee (Softcube Co, Ltd. Osaka, Japan), 3-D image-matching software. The coronal component angles and sagittal component angles were measured in relation to mechanical axis (MA). In addition, axial femoral component angle was measured in relation to surgical epicondylar axis (SEA) and axial tibial component angle was measured in relation to Akagi line.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 384 - 384
1 Dec 2013
Kuroda Y Ishida K Matsumoto T Sasaki H Oka S Tei K Kawakami Y Matsuzaki T Uefuji A Nagai K Tsumura N Kuroda R Kurosaka M
Full Access

Background:

The axis of the fibula in the sagittal plane are known as a landmark for the extramedullary guide in order to minimize posterior tibial slope measurement error in the conventional total knee arthroplasty (TKA). However, there are few anatomic studies about them. We also wondered if the fibula in the coronal plane could be reliable landmark for the alignment of the tibia. This study was conducted to confirm whether the fibula is reliable landmark in coronal and sagittal plane.

Methods:

We evaluated 60 osteoarthritic knees after TKA using Athena Knee (SoftCube Co, Ltd, Osaka, Japan) 3-D image-matching software. Angle between the axis of the fibula (FA) and the mechanical axis (MA) in the coronal and sagittal plane were measured.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 556 - 556
1 Dec 2013
Tei K Matsumoto T Shibanuma N Kurosaka M Kuroda R
Full Access

Introduction

Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femolo-tibial joint as well as posterior-stabilized polyethylene insert, even if posterior cruciate ligament (PCL) is sacrificed after total knee arthroplasty (TKA). The purpose of this study is an investigation of in vivo kinematics of three different tibial insert designs using computer assisted navigation system intra-operatively in TKA.

Materials and Methods

Sixty-four consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker, New Jersey, USA) were performed using computer assisted navigation system. During surgery, three different designs of polyethylene tibial trial inserts (PS, CS, and cruciate-retaining (CR) polyethylene insert) were inserted respectively after implantation of femoral and tibial components. The kinematic parameters of the soft-tissue balance were obtained by interpreting kinematics curve, which display bicompartmental gaps throughout the range of motion (ROM) after implantation of each trial insert (Figure. 1). During record of kinematics, the surgeon gently lifted the experimental thigh three times, flexing the hip and knee. Deviation of these three values in each ROM was calculated in each tibial insert in each patient for descriptive analysis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 123 - 123
1 Mar 2013
Matsumoto T Muratsu H Kubo S Tei K Sasaki H Matsuzaki T Matsushita T Kurosaka M Kuroda R
Full Access

Backgrounds

In order to permit soft tissue balancing under more physiological conditions during total knee arthroplasties (TKAs), we developed an offset type tensor to obtain soft tissue balancing throughout the range of motion with reduced patella-femoral (PF) and aligned tibiofemoral joints and reported the intra-operative soft tissue balance assessment in cruciate-retaining (CR) and posterior-stabilized (PS) TKA [1, 2]. However, the soft tissue balance in unicompartmental knee arthroplasty (UKA) is unclear. Therefore, we recently developed a new tensor for UKAs that is designed to assist with soft tissue balancing throughout the full range of motion. The first purpose of the present study is to assess joint gap kinematics in UKA. Secondly, we attempted to compare the pattern in UKA with those in CR and PS TKA with the reduced PF joint and femoral component placement, which more closely reproduces post-operative joint alignment.

Methods

Using this tensor, we assessed the intra-operative joint gap measurements of UKAs performed at 0, 10, 30, 45, 60, 90, 120 and 135° of flexion in 20 osteoarthritic patients. In addition, the kinematic pattern of UKA was compared with those of CR and PS TKA that were calculated as medial compartment gap from the previous series of this study.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 242 - 242
1 Jun 2012
Tei K Shibanuma N Kubo S Matsumoto T Matsumoto A Tateishi H Kurosaka M Kuroda R
Full Access

Introduction

Achieving high flexion after total knee arthroplasty (TKA) is one of the most important clinical results, especially in eastern countries where the high flexion activities, such as kneeling and squatting, are part of the important lifestyle. Numerous studies have examined the kinematics after TKA. However, there are few numbers of studies which examined the kinematics during deep knee flexion activities. Therefore, in the present study, we report analysis of mobile-bearing TKA kinematics from extension to deep flexion kneeling using 2D-3D image matching technique.

Materials and Methods

The subjects were 16 knees of 8 consecutive patients (all women, average age 75.9), who underwent primary mobile-bearing PS TKA (P.F.C. sigma RP-F: Depuy Orthopedics Inc., Warsaw, IN, USA) between February 2007 and May 2008. All cases were osteoarthritis with varus deformity. Postoperative radiographs were taken at the position of extension, half-squatting and deep flexion kneeling 3 month after the surgery, and the degrees of internal rotation of the tibial component was measured by 2D-3D image matching technique. Pre- and post-operative ROM was recorded. Then, we compared the absolute value and relative movement of tibial internal rotation between extension, half-squatting and deep flexion kneeling, and evaluated the correlation of the ROM and the internal rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 121 - 121
1 Jun 2012
Kubo S Sasaki H Matsumoto T Muratsu H Ishida K Takayama K Oka S Tei K Sasaki K Kuroda R
Full Access

Introduction

Accurate soft tissue balancing has been recognized as important as alignment of bony cut in total knee arthroplasty (TKA). In addition, using a tensor for TKA that is designed to facilitate soft tissue balance measurements throughout the range of motion with a reduced patello-femoral (PF) joint and femoral component in place, PF joint condition (everted or reduced) has been proved to have a significant effect for intra-operative soft tissue balance. On the other hand, effect of patellar height on intra-operative soft tissue balance has not been well addressed. Therefore, in the present study, we investigated the effect of patellar height by comparing intra-operative soft tissue balance of patella higher subjects (Insall-Salvati index>1) and patella lower subjects (Insall-Salvati indexâ‰/1).

Materials and methods

The subjects were 30 consecutive patients (2 men, 28 women), who underwent primary PS TKA (NexGen LPS-flex PS: Zimmer, Warsaw, IN, USA) between May 2003 and December 2006. All cases were osteoarthritis with varus deformity. Preoperative Insall-Salvati index (ISI) was measured and patients were divided into two groups; the patella higher group (ISIï1/4ž1: 18 knees average ISI was 1.12) and the patella lower group (ISIâ‰/1; 12 knees average ISI was 0.94). Component gap and ligament balance (varus angle) were measured using offset-type tensor with 40lb distraction force after osteotomy with the PF joint reduced and femoral trial in place at 0, 10, 45, 90, 135 degrees of knee flexion. Data of two groups were compared using unpaired t test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 143 - 143
1 Jun 2012
Matsumoto T Kubo S Muratsu H Ishida K Takayama K Matsushita T Tei K Kurosaka M Kuroda R
Full Access

Using a tensor for total knee arthroplasty (TKA) that is designed to facilitate soft tissue balance measurements with a reduced patello-femoral (PF) joint, we examined the influence of pre-operative deformity on intra-operative soft tissue balance during posterior-stabilized (PS) TKA. Joint component gap and varus angle were assessed at 0, 10, 45, 90 and 135° of flexion with femoral trial prosthesis placed and PF joint reduced in 60 varus type osteoarthritic patients. Joint gap measurement showed no significant difference regardless the amount of pre-operative varus alignment. With the procedures of soft tissue release avoiding joint line elevation, however, intra-operative varus angle with varus alignment of more than 20 degrees exhibited significant larger values compared to those with varus alignment of less than 20 degrees throughout the range of motion. Accordingly, we conclude that pre-operative severe varus deformity may have the risk for leaving post-operative varus soft tissue balance during PS TKA.