Lisfranc fracture dislocations are uncommon injuries, which frequently require surgical intervention. Currently, there is varying evidence on the diagnostic utility of plain radiographs (XR) and CT in identifying Lisfranc injuries and concomitant fractures. Our aim was to identify the utility of XR as compared to CT, with the nul hypothesis that there was no difference in fracture identification. A retrospective assessment of patients who had sustained a Lisfranc injury between 2013 and 2022 across two trauma centres within the United Kingdom who underwent surgery. Pre-operative XR and CT images were reviewed independently by 2 reviewers to identify the presence of associated fractures.Background
Methods
Research on midfoot injuries have primarily concentrated on the central column and the Lisfranc ligament without amassing evidence on lateral column injuries. Lateral column injuries have historically been treated with Kirschner wire fixation when encountered. Our aim in this study was to analyse lateral column injuries to the midfoot, their method of treatment and the radiological lateral column outcomes. Our nul hypothesis being that fixation is required to obtain and maintain lateral column alignment.Background
Objective
We retrospectively assessed the value of identifying
impinging osteophytes using dynamic computer simulation of CT scans
of the elbow in assisting their arthroscopic removal in patients
with osteoarthritis of the elbow. A total of 20 patients were treated
(19 men and one woman, mean age 38 years (19 to 55)) and followed
for a mean of 25 months (24 to 29). We located the impinging osteophytes
dynamically using computerised three-dimensional models of the elbow
based on CT data in three positions of flexion of the elbow. These
were then removed arthroscopically and a capsular release was performed. The mean loss of extension improved from 23° (10° to 45°) pre-operatively
to 9° (0° to 25°) post-operatively, and the mean flexion improved
from 121° (80° to 140°) pre-operatively to 130° (110° to 145°) post-operatively.
The mean Mayo Elbow Performance Score improved from 62 (30 to 85)
to 95 (70 to 100) post-operatively. All patients had pain in the
elbow pre-operatively which disappeared or decreased post-operatively.
According to their Mayo scores, 14 patients had an excellent clinical
outcome and six a good outcome; 15 were very satisfied and five
were satisfied with their post-operative outcome. We recommend this technique in the surgical management of patients
with osteoarthritis of the elbow. Cite this article:
Atypical femoral fracture focused on relation of bisphosphonate use, frequently. However, the mechanism of atypical femoral fracture was not yet clarified. Atypical femoral fractures have been kept femoral shaft cortical thickness and BMD, practically. We hypothesized that atypical femoral fractures were associated with impaired bone quality and curvature of femoral shaft. We experienced four atypical femoral fractures. One was subtrochanteric and three were shaft fracture. Two cases received bisphosphonate therapy for 3–5 years. BMD, bone metabolic markers, and bone quality markers were evaluated. Histomorphometry and collagen cross-link analysis were performed. Curvature of femoral shaft and 3-D finite element analysis in one incomplete fracture case were assessed.Introduction
Materials & Methods
Excellent results with use of tapered wedged cementless stem have been reported. The purpose of this study was to clarify the indication of tapered wedged cementless stems for patients with poor bone quality. Sixty-five hemiarthroplasties in 79 patients with diagnosis of femoral neck fracture were performed between February 2004 and August 2011. 14 patients were lost to follow-up after surgery, and it is 19 patients among the leaving 65 patients had the stovepipe canal. There were 2 men and 16 women, with a mean age at time of surgery 85 years (range, 75–92 years). All components were tapered wedged cementless stem (LINEAR: Encore, Kinectiv: ZIMMER). Evaluation of patient followed includes radiographic analysis (canal flare index, canal fill rate, stem alignment, bone reaction, and stem stability) and recording complication.Background
Method
Progressive polyethylene wear is associated with the occurrence of osteolysis, which can lead to component loosening and subsequent revision. Massive wear of the polyethylene liner may result in the penetration of the femoral head through the metal shell. Although metallosis after total hip arthroplasty has been well documented in the literature, extensive metallosis with polyethylene wear-through has been only sparsely described. The purpose of the present study was to assess clinical findings and the results of revision total hip arthroplasty in these cases. We evaluated seven hips in five patients who underwent revision total hip arthroplasty because of metallosis with polyethylene wear-through. The average age of the patients at the time of hip revision was 70.1 years. There were granulomatous cysts surrounding the hip joint and osteolysis in the greater trochanter or in the acetabulum. Eroded metal shells with worn-through polyethylene were exchanged. Kerboull-type acetabular reinforcement device were used in five hips and GAP cup in two. Distal interlocking femoral stems were used in four hips and extensively porous-coated stems in two. All cases with osteolysis were in addition treated with bulk or morselized allograft bone. The mean duration of follow-up was 3 years.INTRODUCTION
METHODS
Anatomical reduction and stable internal fixation has been recommended as the standard treatment for fracture dislocations of the tarsometatarsal (Lisfranc) joint. Many methods of fixation have been utilised including K-wires and screw fixation, the latter being the preferred method as it provides a stronger more stable construct. However, the screws require removal after the injury has healed. We present a different method and technique of stabilisation utilising memory staples. The technique is extra-articular and avoids breaching the TMTJ joint surface, is simple and avoids the necessity of removal of hardware. 11 patients with isolated ligamentous Lisfranc injuries were treated with memory staple fixation over the past 4 years at our centre. Patients' outcome was assessed with use of the Foot & Ankle Disability Index (FADI) Score, the American Foot & Ankle Score, radiographic and clinical follow-up at an average time of 2 years post surgery.Background
Methods
The aetiology of hallux valgus is almost certainly multifactoral.
The biomechanics of the first ray is a common factor to most. There
is very little literature examining the anatomy of the proximal
metatarsal articular surface and its relationship to hallux valgus
deformity. We examined 42 feet from 23 specimens in this anatomical dissection
study.Introduction
Methods
The aetiology of hallux valgus is well published and largely debated. Hypermobility at the TMTJ was initially described by Morton, but it was not till Lapidus that its association with hallux valgus was hypothesized. However, little has been published on the anatomy of the tarsometatarsal joint. Our aim was to determine whether there was an anatomical basis for the coronal hypermobility in hallux valgus. Anatomical dissection was completed on 42 feet from 23 bodies. Presence of hallux valgus was noted (displacement of sesamoids). Measurements and photographs were taken of the first tarsometatarsal joint and all differences noted. The TMTJ articular morphology is variable. There were 3 separate subtypes identified of the metatarsal articular surface.Method
Observations
Equinus contracture of the ankle due to a tight Gastrocnemius has been implicated in the pathogenesis of a number of foot and ankle conditions. There are numerous described procedures for release of the Gastrocnemius such as the Strayer procedure. Our indications for release are in patients with a symptomatic forefoot and an equinus contracture of 5 degrees or more in extension as defined by the Silfverskiöld test. The release is usually combined with a reconstructive procedure. The advantages of our technique are its simplicity, excellent visualisation of the tendon and sural nerve, good wound healing and patient comfort post-operatively. The procedure can be performed without tourniquet. A 2.5cm incision is made over the medial calf, just distal to the Gastrocnemius muscle indentation. The deep fascia is incised and the edge of the tendon can be visualised. Blunt digital dissection is performed on either side of the tendon to develop a plane. A metal Cusco speculum is inserted to visualise the full width of the tendon. The tenotomy is performed starting medially and the last 5mm of the lateral tendon is left uncut. This reduces the chance of iatrogenic injury to the nerve. The tendon bridge can be left if correction is sufficient, otherwise passive dorsiflexion of the ankle results in completion. Post-operatively, patients are able to mobilise fully with crutches and passive ankle physiotherapy is commenced immediately. We performed 22 MAGS procedures in 17 patients. There were no Sural nerve injuries and no wound complications. All patients were delighted with cosmesis. Average pre-operative equinus contracture with the leg extended was 18 degrees. Average intra-operative correction of 24 degrees was obtained and at 3 months follow-up, all patients were able to dorsiflex past neutral.
Aseptic loosening and osteolysis may cause significant periprosthetic femoral bone destruction, often necessitating bypass of the deficient proximal femur to obtain stable fixation in the distal diaphysis. The purpose of the present study was to report our results of femoral component revision using a distally locked revision femoral stem for the treatment of the severe proximal femoral bone loss. We evaluated 21 hips in 20 patients who underwent revision hip arthroplasty associated with Paprosky grade-IIIB or IV femoral deficiencies. Three hips were associated with a Vancouver type-B3 periprosthetic femoral fracture. The mean age at the time of revision was 70.8 (51–82) years old with 5 men and 15 women. The mean duration of follow-up was 5.1 years. The femoral implant used for the revision was the Cannulok Revision Prosthesis in 16 hips and the Huckstep interlocking stem in five. Gaps between the stem and the host bone were filled and impacted with bone chips and morselized bone prior to stem insertion. One femoral implants were resected because of deep infection Subsidence was absent and stable fixation was achieved in all patients. Non-progressive radiolucent lines in zones 1 and 7 according to Gruen’s classification were detected in five cases. Cortical hypertrophy around the interlocking screws were seen in ten cases. No disadvantages or complications of the interlocking screws were observed. All the fractures have united within three to five months. Intraoperative fractures in the diaphyseal area occurred in five hips in which trochanteric osteotomy was used. A diaphyseal fixation of the femoral stem with distal interlocking screws appears to provide primary axial and rotational stability of the prosthesis and early mobilization. This implant may provide a satisfactory alternative for the management of revision hip surgery in the presence of a loose femoral component with massive bone loss. Longer-term follow-up data from this study will be needed to confirm these outcomes.
Aseptic loosening and osteolysis may cause significant periprosthetic femoral bone destruction, often necessitating bypass of the deficient proximal femur to obtain stable fixation in the distal diaphysis. The purpose of the present study was to report our results of femoral component revision using a distally locked revision femoral stem for the treatment of the severe proximal femoral bone loss. We evaluated 21 hips in 20 patients who underwent revision hip arthroplasty associated with Paprosky grade-IIIB or IV femoral deficiencies. Three hips were associated with a Vancouver type-B3 periprosthetic femoral fracture. The mean age at the time of revision was 70.8 (51–82) years old with 5 men and 15 women. The mean duration of follow-up was 5.1 years. The femoral implant used for the revision was the Cannulok Revision Prosthesis in 16 hips and the Huckstep interlocking stem in five. Gaps between the stem and the host bone were filled and impacted with bone chips and morselized bone prior to stem insertion. One femoral implants were resected because of deep infection Subsidence was absent and stable fixation was achieved in all patients. Non-progressive radiolucent lines in zones 1 and 7 according to Gruen’s classification were detected in five cases. Cortical hypertrophy around the interlocking screws were seen in ten cases. No disadvantages or complications of the interlocking screws were observed. All the fractures have united within three to five months. Intraoperative fractures in the diaphyseal area occurred in five hips in which trochanteric osteotomy was used. A diaphyseal fixation of the femoral stem with distal interlocking screws appears to provide primary axial and rotational stability of the prosthesis and early mobilization. This implant may provide a satisfactory alternative for the management of revision hip surgery in the presence of a loose femoral component with massive bone loss. Longer-term follow-up data from this study will be needed to confirm these outcomes.
Total Knee Arthroplasty (TKA) has been widely performed and successful clinical outcomes have been achieved for the patients with knee osteoarthritis which is generally known to cause ADL problem. Clinical and radiographic evaluations are commonly used when evaluating postoperative outcomes, among which kinetic analysis and gait analysis are considered essential to investigate the more detailed effect of the treatment. There is a controversy whether performing TKA on both knees simultaneously is appropriate in treating patients with bilateral knee osteoarthritis, in terms of the speed and effectiveness of gait recovery. In this study, we reviewed the significance of performing simultaneous bilateral TKA, by the results of preoperative and postoperative gait analysis.
We noted 1 case of iatrogenic ulnar nerve injury, 2 cases of cubitus varus @ 1 year associated with medial column comminution, 2 cases of hypertrophic scar formation and 3 cases of asymptomatic cubitus valgus. No deep infection. 2 superficial infections.
Considerable controversy exists with regard to the surgical management of displaced intra-articular calcaneal fractures. Protagonists for internal fixation would suggest there is sufficient evidence to expect better functional outcomes with surgery. However, this is not conclusive.
To identify factors which improved outcome following surgery.
Between 1994–2000, 28 patients with 30 displaced intra-articular fractures of the calcaneum were treated with open reduction and internal fixation at our hospital (mean age 45 years). We reviewed 20 patients within the Shropshire region using four recognised hindfoot scoring systems. Patients were classified according to Sanders’ classification with pre-operative CT scans. The mechanism of injury and post-operative management were recorded. Clinical and radiographic assessments were also made.
Average follow-up was 3.6 years. The overall surgical results were comparable with similar studies based upon the Maryland Foot Score (30% excellent, 35% good, 30% fair, 5% poor). Seventy-five percent of our patients returned to work within six months at an average of five months. Three patients developed a superficial wound infection. Age, energy of injury, time to surgery, time spent in plaster and time to commencing physiotherapy had no significant bearing on functional outcome. However, early weightbearing at six weeks positively influenced outcome with all four scoring systems (p=0.01, 0.01, 0.02, 0.05) with a deterioration of outcome with delayed weightbearing. This was shown to be due to loss of subtalar joint mobility (r=−0.74, p=0.001).
We propose that good results can be obtained from internal fixation of intra-articular calcaneal fractures with a high probability of early return to work. We recommend that patients be encouraged to weightbear at 6 weeks to optimise mobility at the subtalar joint.