Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 50 - 50
1 Jan 2016
Takemori T Muratsu H Takeoka Y Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the post-operative knee joint stability quantitatively at one month, six months and one year after surgery, and compared these parameters between CR and PS TKAs.

Material and Method

Sixty patients with varus osteoarthritis of the knee underwent TKAs (30 CR TKAs: CR and 30 PS TKAs: PS). Mean varus deformity in standing position was 11.1 degrees in CR, and 12.6 degrees in PS. All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angles.

One month, six months and one year after surgery, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10kg) and at flexion by epicondylar view with 1.5kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test. The change of joint looseness in each group was analyzed using repeated measures ANOVA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 442 - 442
1 Dec 2013
Muratsu H Kirizuki S Kihara S Takeoka Y Matsumoto T Maruo A Miya H Kuroda R Kurosaka M
Full Access

[Introduction]

Rapid increase of aged population has been one of major issue affecting national health care plan in Japan. In 2006, Japanese Orthopaedic Association indicated a new clinical entity of musculoskeletal ambulation disorder symptom complex (MADS) to define the higher risk of fall and ambulatory disability in the elderly population caused by musculoskeletal disorders. Osteoarthritis of the knee is one of major cause of MADS. The number of patients with MADS underwent total knee arthroplasty (TKA) had been increased in Japan, and also expected to increase worldwide in the near future. The effectiveness of TKA for the patient with MADS would be a key issue for the patient satisfaction in TKA. In the present study, we analyzed the influence of pre-operative factors on the ambulatory functions in the patients of primary TKA.

[Material & Method]

132 patients with osteoarthritic knees implanted with posterior-stabilized (PS) TKAs were subjected to this study. There were 113 female and 19 male patients. The mean age of the patients was 73.6 years (range, 59 to 87 years). Patients were pre-operatively subjected to 2 functional performance tests which were essential tests for MADS diagnosis. Firstly, 3 meter timed up and go test (TUG) was used to evaluate ambulation ability. Secondary one leg standing time (ST) with open eyes was measured with both operated and non-operated leg to assess balancing ability. MADS was diagnosed if TUG and ST were not less than 11 seconds and/or less than 15 seconds respectively. The influence of each pre-operative factor was evaluated simple linear regression analysis (p < 0.05). Pre-operative factors consisted of age, sex, weight, height, BMI, standing femoro-tibial angle (FTA) and active knee range of motion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 180 - 180
1 Dec 2013
Takeoka Y Muratsu H Kihara S Matsumoto T Miyaji N Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the early post-operative knee joint stability quantitatively, and compared these parameters between CR and PS TKA.

Material and Method

Seventy patients with varus osteoarthritis of the knee underwent TKAs (35 CR TKAs: CR and 35 PS TKAs: PS). Mean varus deformity in standing position was 9.8 degrees in CR, and 10.7 degrees in PS (p = 0.45). All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis (SEA) in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angle.

Four weeks after operation, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10 kg) and at flexion by epicondylar view with 1.5 kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Joint looseness was defined as the average of MJL and LJL.

Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test.