Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 38 - 38
1 Feb 2020
Tamaoka T Muratsu H Tachibana S Suda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

Patients-reported outcome measures (PROMs) have been reported as the important methods to evaluate clinical outcomes in total knee arthroplasty (TKA). The patient satisfaction score in Knee Society Score (KSS-2011) has been used in the recent literatures. Patient satisfaction was subjective parameter, and would be affected by multiple factors including psychological factors and physical conditions at not only affected joint but also elsewhere in the body. The question was raised regarding the consistency of patient satisfaction score in KSS-2011 to other PROMs.

The purpose of this study was to investigate the correlation of patient satisfaction in KSS-2011 to other categories in KSS-2011 and to other PROMs including Forgotten Joint Score (FJS-12), EuroQol-5 Dimensions (EQ-5D) and 25-questions in Geriatric Locomotive Function Scale (GLFS-25).

Material & Method

83 patients over 65 years old with osteoarthritic knees were involved in this study. All patients underwent CR-TKAs (Persona CRR). The means and ranges of demographics were as follows: age; 74.5 years old (65–89), Hip-Knee-Ankle (HKA) angle; 12.4 (−6.2–22.5) in varus. We asked patients to fulfill the questionnaire including KSS-2011, FJS-12, EQ-5D and GLFS-25 at 1-year postoperative follow-up visit. KSS-2011 consisted of 4 categories of questions; patient satisfaction (PS), symptoms, patient expectations (PE), functional activities (FA).

We evaluated the correlation of PS to other PROMs using simple linear regression analyses (p<0.001).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 84 - 84
1 Apr 2019
Tachibana Muratsu Kamimura Ikuta Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Background

The posterior slope of the tibial component in total knee arthroplasty (TKA) has been reported to vary widely even with computer assisted surgery. In the present study, we analyzed the influence of posterior tibial slope on one-year postoperative clinical outcome after posterior-stabilized (PS) -TKA to find out the optimal posterior slope of tibial component.

Materials and Method

Seventy-three patients with varus type osteoarthritic (OA) knees underwent PS-TKA (Persona PSR) were involved in this study. The mean age was 76.6 years old and preoperative HKA angle was 14.3 degrees in varus. Tibial bone cut was performed using standard extra-medullary guide with 7 degrees of posterior slope.

The tibial slopes were radiographically measured by post-operative lateral radiograph with posterior inclination in plus value. The angle between the perpendicular line of the proximal fibular shaft axis and the line drawn along the superior margin of the proximal tibia represented the tibial slope angle. We assessed one-year postoperative clinical outcomes including active range of motion (ROM), patient satisfaction and symptoms scores using 2011 Knee Society Score (2011 KSS).

The influences of posterior tibial slope on one-year postoperative parameters were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 80 - 80
1 Apr 2019
Ikuta Muratsu Kamimura Tachibana Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Introduction

Modified gap technique has been reported to be beneficial for the intraoperative soft tissue balancing in posterior-stabilized (PS) -TKA. We have found intraoperative ligament balance changed depending on joint distraction force, which might be controlled according to surgeons' fells.

We have developed a new surgical concept named as “medial preserving gap technique (MPGT)” to preserve medial knee stability and provide quantitative surgical technique according to soft tissue balance measurement using a tensor device.

The purpose of this study was to compare 3-years postoperative knee stability after PS-TKA in varus type osteoarthritic (OA) knees between MPGT and measured resection technique (MRT).

Material & Method

The subjects were 94 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 47 patients and MRT in 47 patients.

An originally developed off-set type tensor device was used to evaluate intraoperative soft tissue balance. In MPGT, medial release was limited until the spacer block corresponding to the bone thickness from proximal lateral tibial plateau could be easily inserted. Femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar resection.

The knee stabilities at extension and flexion were assessed by stress radiographies at 1 and 3 years after TKA; varus-valgus stress test at extension and stress epicondylar view at flexion. We measured medial and lateral joint openings (MJO, LJO) at both knee extension and flexion.

MJOs and LJOs at 2 time periods were compared in each group using paired t-test. Each joint opening distance was compared between 2 groups using unpaired t-test. The significance level was set as P < 0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 106 - 106
1 Jan 2016
Ono S Odake R Tamezawa K Ichishi Y Tachibana Y Yamashita F
Full Access

Introduction

Postoperative knee flexion is an important indicator of success in total knee arthroplasty (TKA). Factors influencing the postoperative range of motion (ROM) were reported to be preoperative ROM, primary indication, height of postoperative joint line, patellar thickness, postoperative pain and rehabilitation. In this study, we aimed to identify the relationship between preoperative hip ROMs and postoperative knee flexion through reviewing the TKA results in Japanese patients.

Patients & Methods

We retrospectively reviewed primary TKAs 55 knees in 55 patients (33 left and 22 right) between April 2012 and March 2013 inclusive. The patients were 11 men and 44 women, with a mean age of 76.7 years. Preoperative hip ROMs and perioperative knee flexion were measured by using goniometer. Hip ROMs were flexion, extension, abduction, adduction, external rotation; ER, internal rotation; IR and total rotation; TR (The total rotation added up ER and IR.). Hip ROMs were measured passively, with the pelvis was fixed manually. Postoperative knee flexion was measured in the fourth week. The patients were classified according to the good group (28 knees), the postoperative knee flexion was more than 125 degrees; and the poor group (27 knees), less than 120 degrees. We compared preoperative hip ROMs in each groups. Multiple regression analysis and Single regression analysis were used for comparison between preoperative hip ROMs and postoperative knee flexion. For comparisons between paired groups we used Wilcoxon test, between unpaired groups Mann-Whitney U test. A p value of less than 0.05 was considered significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 147 - 147
1 Jun 2012
Mizokawa S Arita T Tachibana A Tanabe T Oonishi H
Full Access

INTRODICTION

Since 1985, not resorbable crystalline osteoconductive hydroxyapatite (HA) granules were interposed on the interface between bone and bone cement at the cementation (Interface Bioactive Bone Cement: IBBC) of total hip arthoplasty (THA) to prevent generation of connective tissue and osteolysis for the longevity of cemented THA. To prevent the patients from infection, we are planning to use b-tricalcium phosphate (Beta-TCP) impregnated with antibiotics along with HA granules. However, there have been no reports on the loading and release of antibiotics from fine granules of Beta-TCP. Here, we have investigated the loading of antibiotics on Beta-TCP and their release in vivo.

MATERIALS AND METHODS

Beta-TCP was impregnated with antibiotics such as flomoxef sodium (F), vancomycin hydrochloride (V) cefotiam dihydrochloride (C) and cefozopran hydrochloride (CE) under normal or reduced pressure. After washing with PBS three times, Beta-TCP loaded with the antibiotic was placed in PBS. An aliquot of solution was sampled at appropriate time intervals and the amount of the released antibiotic was estimated based on the anti-bacterial activity.