Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 19 - 19
1 Feb 2017
Hori K Nakane K Terada S Suguro T Niwa S
Full Access

INTRODUCTION

Femur is one of the bones in humans that exhibit ethnic, racial, and gender difference. Several basic and clinical studies were conducted to explore these variations. Clinical anthropological studies have dealt with the compatibility of femoral prostheses and osteosythesis and materials with the femur. If there is a misalignment between the Total Knee Arthroplasy (TKA) femoral comportment installation position, Range of Motion (ROM) failure and several problems may arise. The aim of this study was to evaluate anterior bowing of the Japanese femur and to assess the adequacy of TKA femoral comportment installation position.

METHODS

We analyzed 76 normal Japanese and 97 TKA patients. (June 2014-June 2015) The average age of the normal subjects was 62.0±20.90 (24–88) years old and the average of TKA subjects was 73.6±7.9 (53–89) years old. First we defined and measured the anterior curvature and the posterior condylar offset (PCO) in normal japanese femurs. Then in TKA patients we set the implant as same angle of the component. Third, we measured the post operative anterior curvature and PCO. Then calculated the anterior curvature difference and PCO differences and preformed statistical analysis with ROM.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 227 - 227
1 Jun 2012
Suguro T Yamamoto K Miyazaki Y Nakamura T Sekiguchi M Banks S
Full Access

Aims

Recently, total knee arthroplasty (TKA) has been generalized as an operation that achieves excellent clinical results. However, younger and Asian patients require even greater implant longevity and functional performance. We hypothesized a novel posterior cruciate-retaining TKA design that restores the anatomical jointline in both sagittal and coronal planes, maintains the femoral posterior condylar offset, and provides low contact stress would provide enhanced patient function with the potential for greater implant longevity.

Methods

The novel TKA design was created based on geometry determined from anatomic specimens, 3-degree step of femorotibial jointline was incorporated in the TKA design for Asian. The novel TKA has an asymmetrical design between the medial and lateral femoral condyle, the medial femoral condyle designed to be 3 degrees larger than the lateral femoral condyle. It refined using finite element analyses (FEA) to minimize peak contact stresses. The alignment evaluation after TKA was performed using using bidirectional CR and CT images. Femorotibial-angle (FTA), the position of the femoral component relative to the 3D mechanical axis, and the rotational alignment of the femoral component relative to the PC line were evaluated before and after TKA to identify changes in the femoral condylar shape. The kinematic evaluation after TKA was performed using a 3D-to-2D model registration technique. Single-plane fluoroscopic imaging was used to record and quantify the motions of knees during a stair-step activity. The contact points between the tibiofemoral motions and the tibial rotational angle were evaluated.