header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 1 - 1
8 Feb 2024
Gunia DM Pethers D Mackenzie N Stark A Jones B
Full Access

NICE Guidelines suggest patients should be offered a Total Hip Replacement (THR) rather than Hemiarthroplasty for a displaced intracapsular hip fracture. We investigated outcomes of patients aged 40–65 who received a THR or Hemiarthroplasty following a traumatic intracapsular hip fracture and had either high-risk (Group 1) or low-risk (Group 2) alcohol consumption (>14 or <14 units/week respectively).

This was a retrospective study (April 2008 – December 2018) evaluating patients who underwent THR or Hemiarthroplasty in Greater Glasgow and Clyde. Atraumatic injuries, acetabular fractures, patients with previous procedures on the affected side and those lost to follow up were excluded. Analysis of length of admission, dislocation risk, periprosthetic fractures, infection risk, and mortality was conducted between both cohorts.

Survival time post-operatively of Group 1 patients with a THR (61.9 months) and Hemiarthroplasty (42.3 months) were comparable to Group 2 patients with a THR (59 months) and Hemiarthroplasty(42.4 months). Group 1 patients with THR had increased risk of dislocation (12.9%; p=0.04) compared to those that received Hemiarthroplasty (2.5%). Group 1 Hemiarthroplasty patients had increased wound infection risk (11.6%) compared to Group 2 (3.7%).

In conclusion, we found that amongst our population the life expectancy of a post-operative patient was short irrespective of whether they had high or low-risk alcohol consumption. A hip fracture may represent increased frailty in our study population. The Group 1 THR cohort presented a higher risk of hip dislocation and periprosthetic fracture. With this in mind, Hemiarthroplasty is a more cost-effective and shorter operation which produces similar results.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking.

We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months).

47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007).

This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.