Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 349 - 349
1 Mar 2013
Takayama G Ide S Kawano S Tsukamoto M Sonohata M Mawatari M
Full Access

Background

The purpose of this study was to analyze the effect of femorotibial alignment (FTA), femoral and tibial component alignment, correction of malalignment, and thickness of tibial osteotomy on implant loosening following total knee replacement.

Methods

We retrospectively reviewed 107 knees in 65 patients with a minimum of six months of follow-up. The 107 knees were operated by two surgeons using BS4+ (Bisurface 4 plus) implant (Japan Medical Materials, Japan); the femoral component was cemented, and the tibial component was either cemented or not cemented by using four screws. All the replacements were performed under same operative procedure with medial para-patellar approach and measured bone technique. The knees were classified into two groups (: I and U) on the basis of postoperative radiological findings that indicate the loosening of tibial components. First, there were not any apparent loosening symptom like radio-lucent lines nor sinking; group-I (intact, n=75). Second, there were some radio-lucent lines around tibial component; subgroup-R (radio-lucent lines, n=25), or some subsidence of component over 2 mm; subgroup-S (subsidence, n=7), and the latter two subgroups were put into group-U (unstable, n=32) all together. We measured preoperative and postoperative alignment (overall FTA, correction of malalignment, and alignment of the tibial and the femoral component in the coronal plane). Furthermore, each thickness of tibial osteotomy was measured with use of preoperative and postoperative radiographs of the knee. These parameters including patient's BMI were compared between two major groups statistically to evaluate the factor influencing the stability of tibial components. Moreover, the thickness of tibial osteotomy were compared between two subgroups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 352 - 352
1 Mar 2013
Tsukamoto M Ando Y Noda I Akiyama T Eto S Yonekura Y Kawano S Sonohata M Miyamoto H Mawatari M
Full Access

Problems

Biofilm infections are increasingly associated with orthopedic implants. Bacteria form biofilms on the surfaces of orthopedic devices. The biofilm is considered to be a common cause of persistent infections at a surgical site. The growth and the maturation of biofilm are enhanced by the flow of broth in culture environment. In order to reduce the incidence of implant-associated infections, we developed a novel coating technology of hydroxyapatite (HA) containing silver (Ag). We previously reported that the Ag-HA coating inhibits biofilm formation under flow condition of Trypto Soy Broth + 0.25% glucose for 7 days. In this study, we evaluated whether the Ag-HA coating continuously inhibits the biofilm formation on its surface under flow condition of fetal bovine serum, which contains many in vivo substrates such as proteins.

Materials and Method

The commercial pure titanium disks were used as substrates. Ag-HA or HA powder was sprayed onto the substrates using a flame spraying system. The HA coating disks were used as negative control. The biofilm-forming methicillin resistant Staphylococcus aureus (BF-MRSA; UOEH6) strain was used. The bacterial suspension (about 105 colony forming units) was inoculated into 24-well sterile polystyrene tissue culture plates. The Ag-HA and HA coating disks were aseptically placed in the wells. After cultivation at 37°C for 1 hour, the disks were rinsed twice with 500 μL sterile PBS (−) to eliminate the non-adherent bacteria. After rinsing, the disks were transferred into petri-dish containing heat-inactivated FBS with a stirring bar on the magnetic stirrer and they were cultured at 37 °C for 24 hours, 7 and 14 days. In the meantime, the stirring bar was spun at 60 rounds per minute. Then, the disks were immersed in a fluorescent reagent to stain the biofilm. Finally, the biofilm on each disk was observed by a fluorescence microscope and the biofilm-covered rate (BCR) on the surfaces of them was calculated using the NIH image software.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 338 - 338
1 Mar 2013
Sonohata M Kawano S Kiajima M Tsukamoto M Takayama G Mawatari M
Full Access

Background

Subtrochanteric femoral shortening and corrective osteotomy are considered to be an integral part of total hip arthroplasty for a completely dislocated hip or severe deformity of the proximal femur. A number of alternative femoral osteotomy techniques, transverse, oblique, step-cut, and V-shaped, have been described. Becker and Gustilo reported the “double-chevron subtrochanteric shortening derotational femoral osteotomy,” which is reasonable in that the osteotomy site is torsionally more stable and can be stabilized with a shorter stem. We have simplified this procedure, and performed it without a trochanteric osteotomy. We describe a simplified double-chevron osteotomy and provide the clinical results from a series of 22 successful procedures.

Methods

In this series, we performed 22 cementless total hip arthroplasties combined with double-chevron subtrochanteric osteotomies between 1997 and 2002. There were 17 females and 2 males. Their average age at the time of the operation was 59 years old (range, 41–74 years old). Thirteen of these hips were congenitally dislocated hips (Crowe IV), and 8 hips were after proximal femoral osteotomies using a procedure described by Schanz or valgus osteotomy, and 1 hip was an ankylosed hip in malposition.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 214 - 214
1 Mar 2013
Kawano S Sonohata M Takayama G Tsukamoto M Kiajima M Mawatari M
Full Access

Background

Dislocation is one of the commonest complications of total hip arthroplasty (THA) with incidence of between 0.3 and 10% in primary, and from 15 % to 30% of revision cases. Despite this, little is known of the outcome of treatment strategies for dislocation. In this study, we evaluated clinical results in patient undergoing revision THA for recurrent dislocation.

Materials and Methods

Twenty-four hips underwent revision THA for recurrent instability between 1998 and 2011 at our institution. Nine patients were male, and 15 were female. At the time of revision, the average age was 69.9 years (range, 45–83 years). Average follow-up was 29.8 months (range, 6–72 months). We recorded the number of times of dislocation, the direction of dislocation, the factor of dislocation and the operative strategy employed for each case. Demographic data and surgical treatment used were analyzed to determine risk factors for failure. We performed Mann-Whitney rank sum test, Student's t-test and Fisher exact test to evaluate the factors influencing failure. Significance was defined as a p value of <0.05 (Statistical Package for Social Sciences (SPSS) version 12.0 J for Windows (SPSS Inc., Chicago, IL, USA)).