The use of cementless acetabular components is currently the gold standard for treatment in total hip arthroplasty (THA). Porous coated cups have a low modulus of elasticity that enhances press-fit and a surface that promotes osseointegration. Monoblock acetabular cups represent a subtype of uncemented cup with the liner moulded into the metal shell, minimizing potential backside wear and eliminating the chance of mal-seating. The aim of this study was to compare the short-term clinical and radiographic performances of a modular cup with that of a monoblock cup, with particular interest in the advent of lucent lines and their correlation with clinical outcomes. In this multi-surgeon, prospective, randomized, controlled trial, 86 patients undergoing unilateral THA were recruited. Participants were randomized to either a porous-coated, modular metal-on-polyethylene (MoP) acetabular component (n=46) or a hydroxyapatite (HA)- and titanium-coated monoblock shell with ceramic-on-ceramic (CoC) bearing (n=42). The porous-coated cup had an average pore size of 250 microns with an average volume porosity of 45%, whereas the monoblock shell had an average pore size of 300 microns with an average volume porosity of 48% and a HA coating thickness of 80 nm. There were no baseline demographic differences between both groups regarding sex, age, body mass index (BMI), or American Society of Anaesthesia (ASA) class (p>0.05). All of the sockets were under-reamed by 1 mm. Radiographs and patient-reported outcome measures (PROMs), including modified Harris Hip Score (mHHS), Western Ontario and McMaster Universities Arthritis Index (WOMAC) and University of California at Los Angeles (UCLA) Hip Score, were available for evaluation at a minimum of 2 years of follow-up. A radiolucent distance between the cup and acetabulum of ≥0.5 mm was defined as gap if it was diagnosed from outset or as radiolucency if it had sclerotic edges and was found on progressive x-ray analyses. Thirty-two gaps (69%) were found in the modular cup group and 28 (6%) in the monoblock one (p=0.001). Of the former, 17 filled the gaps whereas 15 turned into a radiolucency at final assessment. Of the latter, only 1 of the gaps turned into a radiolucency at final follow-up (p 0.05) in both groups. Only the porous-coated cup was an independent predictor of lucent lines (OR:0.052, p=0.007). No case underwent revision surgery due to acetabular loosening during the study period. Only 2 cases of squeaking were reported in the CoC monoblock shell. Both porous-coated modular and hydroxyapatite-coated monoblock cups showed successful clinical results at short-term follow-up, however, the former evidenced a significantly higher rate of radiolucent line occurrence, without any association with PROMs. Since these lines indicate the possibility of future cup loosening, longer follow-up and assessment are necessary.