Deep joint infection is one of the most dreaded complications of total joint arthroplasty, and urinary tract infections (UTI) are generally believed to be a source for haematogenous seeding of the prosthetic joint. Although patients are often screened for UTI there appears to be minimal evidence on the management of asymptomatic bacteriuria, or for those patients who perform intermittent self-catheterisation prior to joint arthroplasty. This study aims to address this. We performed an online and postal survey of the British Association for the Surgery of the Knee membership to provide a consensus from a body of professionals. Of the respondents 75% performed 50 or more joint arthroplasty surgery over a 12 month period. For all surgeons, 71.4% provided antibiotic cover for the insertion and withdrawal of urinary catheters. However, only 19% were aware of National guidelines, compared to 76.2% for local guidelines which were more likely to be followed. Two thirds of surgeons would treat asymptomatic bacteriuria prior to surgery, yet 70% of these surgeons were unable to cite evidence for this decision. Similarly, the management of patients requiring intermittent self-catherisation produced a heterogenous response. Our study suggests there is a lack of consensus and/or awareness amongst specialist knee surgeons for the management of asymptomatic urinary bacteriuria in patients prior to knee surgery. We believe a minimum standard of care be defined by the society to protect both patient and surgeon.
We have piloted a new system of purely therapist led clinics and assessed this with an anonymous patient survey.
The indication for revision was aseptic loosening in 16 cases, and deep sepsis in 13 cases, (12 were done in 2 stages). Others included polyethylene wear in 4 knees, instability in 2, and 1 each of peri-prosthetic fracture, implant breakage and pain of undetermined origin. 3 revisions were performed for failed Link Lubinus patello-femoral replacement. Mean interval between staged procedures for sepsis was 2 months. Reconstruction was performed using the Kinemax Revision system with the use of augments and stems. The modular rotating hinge was used in 4 cases. Surgical exposure included additional lateral release in 7 cases, tibial tubercle osteotomy in 4 and quadriceps snip in one.
At latest review, 7 patients had died due to unrelated causes with a pain free functioning knee prosthesis. Of the remaining 31, 26 patients had none or minimal pain. 21 were independently mobile with a satisfactory range of motion.10 patients needed a walking stick.