Sellers E Fearon P Ripley C Vincent A Barnard S Williams J
Full Access

High energy chest trauma resulting in flail chest injury is associated with increased rates of patient morbidity. Operative fixation of acute rib fractures is thought to reduce morbidity by reducing pain and improving chest mechanics enabling earlier ventilator weaning.

A variety of operative techniques have been described and we report on our unit's experience of acute rib fracture fixation. Over 18 months, 10 patients have undergone acute rib fracture fixation. Outcome measures included; patient demographics, time ventilated pre-operatively, time ventilated post-operatively and time spent on ITU/HDU post operatively.

The mean time from presentation to surgery was 5 days (range 2–12 days). The mean time ventilated post operatively was 2 days (range 1–4 days) and the mean number of days spent on ITU/HDU post-operatively was 6 days (range 2–11 days).

Our results appear positive in terms of time spent ventilated post-operatively but no conclusion can be drawn as we have no comparable non-operative group. We have however shown, that rib fracture fixation can be carried out successfully and safely in a trauma centre. Further evidence on rib fracture fixation is required from a large, multi-centre randomised controlled trial.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 7 - 7
1 Jul 2012
Agni N Sellers E Johnson R Gray A
Full Access

The aim of this study was to establish any association between implant cut-out and a Tip Apex Distance (TAD), ≥25mm, in proximal femoral fractures, following closed reduction and stabilisation, with either a Dynamic Hip Screw (DHS) or Intramedullary Hip Screw (IMHS) device. Furthermore, we investigated whether any difference in cut-out rate was related to fracture configuration or implant type.

WE conducted a retrospective review of the full clinical records and radiographs of 65 consecutive patients, who underwent either DHS or IMHS fixation of proximal femoral fractures. The TAD was measured in the standard fashion using the combined measured AP and lateral radiograph distances. Fractures were classified according to the Muller AO classification.

35 patients underwent DHS fixation and 30 patients had IMHS fixation. 5 in each group had a TAD≥25mm. There were no cut-outs in the DHS group and 3 in the IMHS group. 2 of the cut-outs had a TAD≥25mm. The 3 cut-outs in the IMHS group had a fracture classification of 31-A2, 31-A3 and 32-A3.1 respectively. In addition, the fractures were inadequately reduced and fixed into a varus position.

A TAD<25mm would appear to be associated with a lower rate of cut-out. The cut-out rate in the IMHS group was higher than the DHS group. Contributing factors may have included an unstable fracture configuration and inadequate closed fracture reduction at the time of surgery.