Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 47 - 47
22 Nov 2024
Mitterer JA Hartmann SG Simon S Sebastian S Chlud L Hofstaetter JG
Full Access

Background

Two-stage revision arthroplasty is the standard treatment for chronic hip and knee periprosthetic joint infections (PJI). Accurate diagnosis of persistent infections at 2nd stage using established biomarkers and diagnostic criteria is of paramount importance. This study aimed to evaluate the diagnostic value of synovial calprotectin and alpha-defensin, and compare established diagnostic criteria from the International Consensus Meeting (ICM 2018) and the European Bone and Joint Infection Society (EBJIS 2021) to determine persistent PJI at the 2nd stage of a two-stage revision arthroplasty.

Methods

We retrospectively analyzed 97 patients who underwent 100 two-stage revisions (hip: 39, knee: 61). Synovial fluid samples were assessed for calprotectin and alpha-defensin levels. ICM 2018 and EBJIS 2021 were applied to all patients undergoing 2nd stage revision. Receiver operating characteristic (ROC) curves and Youden Index were utilized to determine optimal cut-off values, and correlations between biomarkers were evaluated. The microbiological spectrum was analyzed at 2nd stage and re-revision surgery.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 76 - 76
22 Nov 2024
Gardete-Hartmann S Sebastian S Berdalli S Simon S Hofstaetter J
Full Access

Aim

Unexpected negative-cultures (UNC) are a common diagnostic problem in periprosthetic joint infection (PJI) of the hip and knee when using culture-based methods. A novel molecular approach (MC)1 based on the identification of the vast majority of bacterial species in a single assay using species-specific bacterial interspacing region length polymorphisms and phylum-specific 16S rDNA sequence polymorphisms has demonstrated clinical utility in PJI diagnostics (1). In addition, MC provides an estimate of the leukocyte concentration in the specimen analysed. The aim of this retrospective, blinded study was to evaluate the performance of MC in identifying the microbiological content and determining the leukocyte count in synovial fluid (SF) collected from hip and knee revision arthroplasty cases with UNC. It was also assessed whether antibiotic treatment would have been changed if the result from MC had been known.

Method

A total of 89 SF samples from 70 patients (43 female; 27 male) who underwent revision arthroplasty (14 hip; 75 knee) were included. Using European and Bone Joint Infection Society (EBJIS) criteria, 82 cases were classified as infected (77 UNC and 5 septic culture-positive controls), five as non-infected (aseptic culture-negative controls), and two as likely infected, but infected by clinical observation. MC was performed and evaluated together with SF parameters. Antibiotic treatment, clinical outcome, patient demographics and surgical details were analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 67 - 67
24 Nov 2023
Gardete-Hartmann S Simon S Frank BJ Sebastian S Loew M Sommer I Hofstaetter J
Full Access

Aim

Synovial calprotectin point-of-care test (POC) has shown promising clinical value in diagnosing periprosthetic joint infections (PJIs). However, limited data are available in unclear cases. Moreover, cut-off values for calprotectin lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) need to be adapted. The aim of this study was to evaluate the performance of an upgraded and more sensitive version of a synovial calprotectin LFA along with ELISA immunoassay in patients with septic, aseptic, and unclear cases.

Methods

Overall, 206 prospectively collected periprosthetic synovial fluid samples from 169 patients (106f/63m; 38 hip/131 knee) who underwent revision surgeries were retrospectively evaluated for calprotectin concentration. The following groups were analyzed: unexpected negative cultures (UNC; 32/206), unexpected positive cultures (UPC; 28/206), and unclear cases (65/206) with conflicting clinical results. In addition, we added a true aseptic (40/206), and true septic (41/206) control groups according to the international consensus meeting (ICM) 2018 PJI classification. Calprotectin concentration was determined by a rapid quantitative LFA (n=206) (Lyfstone®, Norway), and compared to calprotectin ELISA immunoassay (171/206). For the determination of a new calprotectin cut-off value, analysis of the area under the curve (AUC) followed by Youden's J statistic were performed using the calproctectin values from clear septic and aseptic cases. Sensitivity and specificity for calprotectin were calculated. All statistical analyses were performed using IBM-SPSS® version 25 (Armonk, NY, USA).