Spontaneous osteonecrosis of the knee (SONK) mainly affects the medial femoral condyle, would be a good indication for UKA. The primary aim of this study was to assess the clinical, functional and radiographic outcomes at middle to long-term follow-up, of a consecutive series of fifty UKA used for the treatment of SONK. The secondary aim was to assess the volume of necrotic bone and determine if this influenced the outcome. We reviewed 50 knees who were treated for SONK. Patients included ten males and 38 females. The mean age was 73 years (range, 57 to 83 years). The mean height and body weight were, respectively 153 cm (141 ∼171 cm) and 57 kg (35 ∼75kg). All had been operated on using the Oxford mobile-bearing UKA (Zimmer-Biomet, Swindon, United Kingdom) with cement fixation. The mean follow-up period was 8.4 years (range, 4 to 15years). We measured the size (width, length and depth) and the volume to be estimated (width x length x depth) of the necrotic bone mass using MRI in T1-weighted images. The clinical results were evaluated using the Knee Society Scoring System (KSS) and Oxford Knee Score (OKS). The flexion angle of the knee was evaluated using lateral X-ray images in maximum flexion.Aims
Patients and Methods
Most Japanese patients who receive total hip arthroplasty (THA) are osteoarthritic and 70% have development dysplasia of the hip. Their stature is shorter than average and their sizes (acetabular cup and femoral stem) are smaller. The Taperloc Microplasty (BIOMET) is a short femoral stem. It was launched on July 2012 in Japan (extended on January 2013). It is essentially a shortened version of the Taperloc stem (35mm shorter than the standard stem). We aimed to evaluate the outcomes of minimally invasive anterolateral THA using a short stem.Introduction
Objectives
In recent years, an increasing number of reports related to adverse reactions to metal debris (ARMD) following metal-on-metal (MOM) total hip arthroplasty (THA) have been published. Some patients who experience ARMD require revision surgery. In this study, we aimed to evaluate the mid-term results of MOM THA.Introduction
Objectives
In February 2004, our institute began to perform routine cervical CT scans in addition to head CT examinations on patients with blunt head trauma who had received high energy injuries. We present the findings of 108 patients who underwent a routine cervical CT within the last year and the usefulness of routine cervical CT examinations is discussed. The present report is, to our knowledge, the only prospective study to examine the utility of routine cervical CT examinations. Among the patients admitted to the emergency room of our institute after receiving high energy injuries, 108 patients had blunt head trauma and underwent a routine cervical CT examination in addition to the head CT examination specified by our original protocol for cervical clearance. The mechanism of injury and the presence of cervical bone lesions were noted in each case. 76 males and 32 females ranging in age from 13 to 77 years (average, 41.0 years) were included in the study. Among these 108 cases, cervical fractures or subluxation were visible in 5 cases on plain films. Although no fractures were seen on the plain films taken in the remaining 103 cases, the additional cervical CT examinations demonstrated 14 cervical fractures in 13 (12.6%) of these cases. For patients with blunt head trauma, a cervical CT examination is not usually performed if no evidence of a cervical fracture is found on plain films and no neurological deficits are present. Nevertheless, the present findings suggest that many cervical fractures may have been missed on plain films in the past, and the routine inclusion of a cervical CT examination in addition to a head CT examination might be appropriate in the evaluation of patients with blunt head trauma who have been involved in a high energy injury.