In conclusion after a 14 year experience we can assert that neck preservation combined with a proximal lateral flare support guarantees a more natural loading of the femur and large indications. The absence of the stem makes this implant ideal not only for conventional surgical approach but also for MIS.
Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem. We report the outcome of 129 custom-made hydroxyapatite-coated uncemented short femoral components inserted into 109 patients between June 1995 and May 2004. The mean age of the patients was 51 years (21 to 71) and the mean follow-up was eight years (4.9 to 14.1). Bone behaviour around the implant was studied on the post-operative radiographs. The mean Harris hip score improved from 44 (8 to 66) pre-operatively to 95 (76 to 100) at final follow-up. The Western Ontario MacMaster University Osteoarthritis index was 93 of 100 at final review. None of the patients reported thigh pain. A total of five hips were revised, three for polyethylene liner exchange and two for complete revision of the acetabular component. No femoral components were revised. The radiological changes in the proximal femur were generally good, as evidenced by spot welds both on the medial and lateral aspects of the femur. No component migrated. The presence of a lateral flare and use of a high osteotomy of the femoral neck provided good clinical and radiological results. The absence of a diaphyseal portion of the stem did not impair stability.
Following this philosophy, an original ultra-short stem with extensive proximal load transfer was developed. Purpose of this paper is to present clinical and radiological results at 4 yrs average follow up.
Hip arthroscopy is a well-established technique becoming more and more an indispensable tool in institutions specialized in hip diseases. Several surgeons around the world have developed and refined the proper instruments and the surgical technique for this operation. By now, the indications have been well formulated for both diagnostic and interventional purposes. My personal experience is of 98 hip arthroscopies performed in the last 6 years. Most common preoperative indication has been chronic hip pain after failure of conservative treatment. Other indications or arthroscopic findings have been: labral pathology, hip dysplasia, synovial chondromatosis, initial osteoarthritis, calcium pyrophosphate disease, ligamentum teres damage, chondral damage, post-traumatic loose bodies, avascular necrosis, sepsis, villonodular synovitis. More recent, indications for hip arthroscopy are staging of avascular necrosis of the femoral head and shaving of polyethylene debris after total hip replacement. Contraindications to arthroscopy include recent fracture of the pelvis osteoarthritis with osteophytosis, AVN with head collapse. Hip arthroscopy can facilitate both comprehensive access to and treatment of an evolving series of conditions that affect the hip joint. Purpose of this presentation is to show the surgical technique and present the results obtained. New indications and potential future evolutions are also discussed.
Different techniques are available but many surgeons have recently expressed a preference for retrograde nailing. We present our results with new generation retrograde self-locking nail.
Proximal locking, in this device, is obtained by the angled protrusion of a wire from the nail proximal extremity. Experimental tests in the lab have confirmed the excellent torsion stability of this mechanism. Distally, the EXP nail has two little wings shaped to sit on the medial and lateral columns of the olecranic fossa and to thus provide an effective rotational and traction control. We treated 67 traumatic fracture, 15 pathological fractures, 10 impending fracture and 20 a non-unions. 10 patients in this series were obese.
Union was obtained in all the 67 primary fractures and stability was secured for all the impending and pathological cases. All but 1 non-union healed after an average of 2.6 months. In 2 patients of the primary fractures and in 3 patients of the non-union group we had a delayed union. The 3 non-union patients healed after 5, 7 and 9 months respectively. Overall 9 of the 10 obese patients healed. No patients suffered shoulder pain. In 8 cases a reduction of less than 10 degrees of elbow extension was detected. Forty-five nails have been removed so far after an average of 11 months after nailing. No major problems in nail removal have been encountered.
Ð in CDH primary implant Ð in revision surgery (grade 2–4 according to Paproskyñs classiþcation). In severe bone loss cases (grade 3–4) we preferred to use auto or homologous bone grafts impacted to þll the bone defect. Radiolucency around stem <
2 mm. 19 cases, radiolucency around the cup in 11 cases; bone grafts resorption 10 out of 57 cases. Mean preoperative Harris Hip Score was 60; mean postoperative HHS 85.
In 30 cases the disease was in Steinberg stage I, 58 stage II, 42 stage III and 17 stage IV. All patients were kept non weight bearing for 6 weeks and partial weight bearing for further 6 to 8 weeks. PEMF were used for 8 ours daily for 3 months. Average follow-up was 37 months (min 12 months, max 108). Both clinical and radiological results were evaluated.
The proximal locking is achieved by the protrusion of a wire into the medullary bone of the humeral head. Distally the EXP nail has two small wings shaped to sit on the medial and lateral columns of the olecranon fossa.
We performed a randomised controlled study to compare heparin with the A-V Impulse System in the prevention of deep-vein thrombosis (DVT) in 132 consecutive patients undergoing total hip replacement. After the operation, all patients had compression stockings, 65 were treated with calcium heparin and 67 with the intermittent plantar pump. DVT was diagnosed by Doppler ultrasound and thermography, followed by phlebography. There were 23 cases of DVT (35.4%) in the heparin group, with 16 major and seven minor thromboses. In the impulse pump group there were nine cases (13.4%) with three major and six minor thromboses. The differences for all thromboses and for major thromboses were both significant at p <
0.005. In the heparin group there was one fatal pulmonary embolism and nine patients (13.8%) had excessive bleeding or wound haematomas, as against none in the impulse pump group.