Vol. 97-B, Issue SUPP_14 | Pages 7 - 7
1 Dec 2015
Vaughan P Salt G Thorisdottir V Deakin S
Full Access

Introduction

Despite costing up to 5X more than a one-third tubular plate (TTP) and no absolute indications, distal fibula locking plates (DFLP) are becoming increasingly popular in the fixation of ankle fractures, particularly in the elderly. We reviewed all our distal fibula fracture fixations, over the course of one year, in order to rationalise DFLP use.

Methods

Patient demographics, Weber classification, use of DFLP or TTP and the mode of fixation were recorded. Open fractures and tibial plafond fractures were excluded.