1 Apr 2013
Ikeda S Sakai A Tanaka H Takeuchi Y Ohnishi H Murakami H Saito M Ito M Nakamura T
Full Access

Introduction

Atypical femoral fracture focused on relation of bisphosphonate use, frequently. However, the mechanism of atypical femoral fracture was not yet clarified. Atypical femoral fractures have been kept femoral shaft cortical thickness and BMD, practically. We hypothesized that atypical femoral fractures were associated with impaired bone quality and curvature of femoral shaft.

Materials & Methods

We experienced four atypical femoral fractures. One was subtrochanteric and three were shaft fracture. Two cases received bisphosphonate therapy for 3–5 years. BMD, bone metabolic markers, and bone quality markers were evaluated. Histomorphometry and collagen cross-link analysis were performed. Curvature of femoral shaft and 3-D finite element analysis in one incomplete fracture case were assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 45 - 45
1 Apr 2013
Zenke Y Sakai A Oshige T Menuki K Murai T Yamanaka Y Furukawa K Nakamura T
Full Access

The previous bioabsorbable plates have had several issues with regard to clinical usage for fractures. The aims of this study were to demonstrate the clinical results of novel bioabsorbable plates made of hydroxyapatite/poly-L-lactide and titanium plates for metacarpal fractures and to compare mechanical properties of them in a fracture model. The subjects were 33 metacarpal diaphyseal fractures of 27 consecutive patients treated with bioabsorbable plates. The mean age was 35.8 (17–78), 22 male and 5 female was included. The mean follow up period was 7.4months (2–14). All cases achieved bone union, and there were no complication especially for aseptic swelling etc.

Furthermore, we compared the mechanical properties of bioabsorbable and titanium plates. There were no significant differences in 6 month postoperative clinical results including total range of active motion and % of the contralateral grip strength between patients receiving bioabsorbable and titanium plates. The bending strength and stiffness of one-third tubular bioabsorbable plate constructs were comparable with those of titanium plates for 1.5mm screws, and those of semi-tubular bioabsorbable plates were comparable with those of titanium plates for 2.0mm screws. The torsional strength of semi-tubular bioabsorbable plates was significantly greater than that of titanium plates for 2.0mm screws.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 102 - 107
1 Jan 2009
Zenke Y Sakai A Oshige T Moritani S Nakamura T

A total of 118 consecutive patients with a fracture of the distal radius were treated with a volar locking plate; 50 patients had no ulnar styloid fracture, 41 had a basal ulnar styloid fracture, and 27 had a fracture of the tip of the ulnar styloid. There were no significant differences in radiological and clinical results among the three groups. The outcome was good and was independent of the presence of a fracture of the ulnar styloid. A total of five patients (4.2%) had persistent ulnar-sided wrist pain at final follow-up. Nonunion of the ulnar styloid fracture did not necessarily lead to ulnar wrist pain. Patients with persistent ulnar pain had a higher mean initial ulnar variance and increased post-operative loss of ulnar variance.

The presence of an associated ulnar styloid fracture of the ulnar styloid does not adversely affect the outcome in patients with a fracture of the distal radius treated by volar plating.