Classical fixation using a circular frame involves two rings per segment and in many units this remains the norm whether using ilizarov or hexapod type frames. We present the results of two ring circular frame at King's College Hospital. A prospective database has been maintained of all frames applied since 2007. Radiographs from frames applied prior to July 2022 were examined. Clinic letters were then used to identify complications. Included: two ring hexapod for fracture, malunion, nonunion, arthrodesis or deformity correction in the lower limb. Excluded: patients under 16 years old, diabetic feet, Charcot joints, soft tissue contractures, arthrodiastasis, correction of the mid/forefoot, plate fixation augmentation, fixation off a third ring.Introduction
Materials & Methods
Fracture related infections (FRI) following intramedullary nailing for tibial shaft fractures remain challenging to treat with associated high patient morbidity and healthcare costs. Recently, antibiotic-coated nails have been introduced as a strategy to reduce implant related infection rates in high-risk patients. We present the largest single-centre case series on ETN PROtect® outcomes reporting on fracture union, infection rates and treatment complications. 56 adult patients underwent surgery with ETN PROtect® between 01/09/17 and 31/12/20. Indications consisted of acute open fractures and complex revision cases (FRI, non-union surgery and re-fracture) with a mean of 3 prior surgical interventions. 51 patients had an open fracture as their index injury. We report on patient characteristics and outcomes including radiological/clinical union and deep infection. The one-year minimum follow-up rate was 87.5%.Introduction
Materials and Methods
The accuracy of hexapod circular external fixator deformity correction is contingent on the precision of radiographic analysis during the planning stage. The aim of this study was to compare the SMART TSF (Smith and Nephew, Memphis, Tennessee) in-suite radiographic analysis methods with the traditional manual deformity analysis methods in terms of accuracy of correction. Sawbones models were used to simulate two commonly encountered clinical scenarios. Traditional manual radiographic analysis and digital SMART TSF analysis methods were used to correct the simulated deformities.Introduction
Materials and Methods
Introduction
Materials and Methods
The aim of this radiographic study was to define the anatomical axis joint centre distance (aJCD) and anatomical axis joint centre ratio (aJCR) of the distal femur in the coronal plane for skeletally mature individuals. A cross-sectional radiographic study was conducted to calculate the horizontal distances between the anatomical axis and the centre of the knee at the level of the intercondylar notch and the joint line. Ratios relating these points to the width of the femur were then calculated.Introduction
Materials and Methods