header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 33 - 33
1 May 2012
H. P S. C
Full Access

Peroneal spastic flatfeet without coalition or other known etiologies in adolescence remain a challenge to manage.

We present eight such cases with radiological and surgical evidence of bony abnormalities in the subtalar region just anterior to the posterior facet. All patients had presented as tertiary referrals with recalcitrant pain and had undergone a trial of orthotics and physiotherapy. Diagnostic workup included a clinical and radiographic evaluation. Clinical examination consisted of gait examination, foot alignment, range of motion, torsional profile of the lower limbs and marking of symptomatic foci. All patients had standing weightbearing AP and lateral projections of the foot and ankle. CT and/or MRI scans of the foot were performed in axial coronal and saggital planes. Coalitions and other intraarticular known pathologies were ruled out. All patients had bilateral flatfeet but unilateral peroneal spasm.

All patients had an accessory talar facet in front of the posterior subtalar facet. This caused lateral impingement between the facet and the calcaneum, confirmed by bone edema around the sinus tarsi. All patients had stiff subtalar joints with very limited movement under anaesthesia, indicating peroneal muscle contracture.

Patients were treated with a combination of facet excision, peroneal lengthening and calcaneal lengthening to correct the flatfoot and prevent lateral impingement.

We propose a mechanism of subtalar impingement between the anterior extra-articular part of the talar lateral process and the Gissane angle and believe that resection of the accessory facet without addressing the the primary driving force for impingement, which is the structural malalignment in flatfeet, would only give partial relief of symptoms. This impingement appears to occur with growth spurts in adolescents, in patients with known flatfeet.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 180 - 180
1 May 2012
R. G C. C S. C R. T S. A L. J
Full Access

Background

Advances in diagnosis and treatment should mean that hindquarter amputation is now rarely needed. Unfortunately this is not the case. We have performed 166 of these amputations in the past 36 years. We have investigated the reasons why this procedure is still required and the outcomes following it.

Method

A retrospective review of data stored on a prospective database.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 94 - 94
1 May 2012
S. C C. P N. K N. F G. B
Full Access

Problems associated with soft tissues of the stump and attachment of prosthetic devices for amputees remains a considerable problem. These problems are associated with the transmission of load through the soft tissues of the stump and difficulty in attaching the prosthetic device. Several devices have an osteointegrated transcutaneous prosthesis attached to the residual bone onto which an exo-prostheses is secured thereby transmitting load directly through the skeleton. Infection of these devices is a key issue.

A biomimetic intraosseous transcutaneous device for amputees known as ITAP has been developed which is based on deer antler morphology. We have shown that in deer antlers the dermal and epithelial tissues are tethered by collagen fibres which originate from pores in the bone. In a caprine model where the soft tissue interface of ITAP is porous, dermal and epithelial integration occurs creating a seal and preventing infection. In two clinical veterinary cases an ITAP implant has been successfully used in trans-radial canine amputees. A human trans-humeral amputee who previously could not wear their exo-prosthesis has been treated with ITAP. The surgery was single stage procedure and involved the insertion of an uncemented intramedullary stem into the residual humerus. A porous flange structure positioned adjacent to the dermal tissue which had most of the hypodermis removed was used to promote soft tissue ingrowth.

At two years' post-operation the skin seal has been maintained, there has been no incidence of infection, the patient wears their exo-prostheses for over 8 hours a day and has an almost complete range of shoulder motion. The use of ITAP device in selected cases may revolutionise the way amputees are surgically treated, lead to increased activity levels and more normal life styles in these patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 177 - 177
1 May 2012
R. G S. C R. T S. A L J
Full Access

Since 1970, 2200 primary endoprosthetic replacements have been carried out at our Unit for bone tumours. 3% were carried out in the 1970s, 21% in the 1980s, 33% in the 1990s and 43% since 2000.

The most common diagnosis was osteosarcoma (839)(38%) followed by metastatic disease (18%) and chondrosarcoma (13%). The most common site was the distal femur (35%) followed by the proximal femur and proximal tibia. The least common sites were the scapula and distal radius. The mean age at operation was 35 but varied widely, being 19 in patients with osteosarcoma and 58 for those with metastases. 239 extendable prostheses were inserted in children. 50% of the patients were alive at 10yrs and 42% at 20yrs. 7% required an amputation either for local recurrence or infection.

The failure rate of the prostheses varied by age and site, with pelvic and proximal tibial replacements having the highest risk of infection and proximal humeral replacements the lowest risk of any complication. The failure rates of the most common prostheses (distal femur and proximal tibia) have improved over time and are now ~ 1.5% per year. Hydroxyapatite collars have largely resolved the problem of aseptic loosening. Silver coated prostheses have been used in 48 complex cases with encouraging results in controlling infection. Functional scores averaged 80% and were the same for revision as for primary implants.

Conclusion

Significant improvements of design have improved endoprosthetic replacements for tumours. Results are now fairly predictable but still not as good as primary joint replacemenrts. Infection remains the most serious challenge.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 80 - 80
1 May 2012
T. S S. C S. T M. C
Full Access

Introduction

Ulnar shortening osteotomy has become an accepted treatment for a variety of ulnar sided wrist disorders. We have been performing ulnar shortening with an oblique osteotomy cut with the aid of a commercially available jig. The osteotomy is then fixed with a Dynamic Compression Plate. The aim of this study was to report the complications following ulnar shortening.

Methods

We retrospectively analysed 56 consecutive ulnar shortening osteotomies. There were 36 female and 19 male patients. The mean age was 45 years. The mean follow-up was 399 days. 25 patients had pre-operative MRI scans and in 34 arthroscopy of the wrist had been performed. 22 tears of the triangular fibrocartilage complex were recorded on arthroscopy. In all cases shortening had been performed with the aid of a jig and bone resection performed in an oblique orientation. Dynamic Compression Plates were used for fixation and a lag screw was inserted through one of the plate-holes and across the osteotomy site. Radiographs were evaluated for pre-operative and post-operative ulnar variances and post-operatively for bony union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 52 - 52
1 May 2012
S. C C. D F. V A. C
Full Access

Background

Rotator cuff tears pose a huge socioeconomic burden. Our study uses Fourier transform infrared spectroscopy (FTIR) as it is a quick, non-manipulative and non-destructive test, which can identify a wide range of chemical targets from small intraoperatively obtained specimens. The aim of this study was (i) to characterise the chemical and structural composition of rotator cuff tendons and (ii) to identify structural differences between anatomically distinct tear sizes. Such information may help to identify specific biomarkers of rotator cuff tear pathologies, which in turn could allow early identification and monitoring of disease progression. FTIR may provide insight into the different healing rates of different tear sizes.

Methods

The infrared spectra of 81 torn rotator cuff tendons were measured using a FTIR spectrometer. The rotator cuff tear sizes were classified as partial, small, medium, large and massive, and compared to 14 normal controls. All spectra were classified using standard multivariate analysis; principal component analysis, partial least square and discriminant function analysis.