Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 9 - 9
10 Oct 2023
Aithie J Robinson P Butcher R Denton M Simpson A Messner J
Full Access

Patellofemoral instability (PFI) is a common cause of knee pain and disability in the paediatric population. Patella alta, lateralised tibial tubercle, medial patellofemoral ligament (MPFL) deficiency, genu valgum and trochlear dysplasia are well known risk factors.

A prospective database was created including patients referred through our physiotherapy pathway following first-time patella dislocation. Patella alta and lateralisation of the tibial tuberosity was treated with a Fulkerson-type tibial tubercle osteotomy(TTO). Medial patellofemoral ligament was reconstructed using quads tendon autograft pull-down technique. A modified Sheffield protocol was used postoperatively allowing weightbearing in a hinged knee brace.

Forty patients were identified with 8 patients having bilateral presentations. Male to female ratio was 12:28 with an age range of 4–17 years. Eight patients had congenital PFI, five patients acquired PFI through traumatic patella dislocation and twenty-seven patients developed PFI from recurrent dislocations. Structural abnormalities were found in 38(95%) of patients. Patella alta (Caton-Deschamps index >1.2) was identified in 19(47%) patients, genu valgum in 12(30%) patients, increased tibial tubercle-trochlear groove distance(TT-TG>20mm) was present in 9(22.5%) patients and persistent femoral anteversion(> 20 deg) in 7(17%) patients.

Eight patients were treated with TTO and MPFL reconstruction, three patients with MPFL reconstruction alone and five patients had guided growth for genu valgum correction. Ten patients are awaiting surgery. No postoperative patients had recurrence of PFI at their latest follow up.

PFI is a common problem in the adolescent paediatric population with identifiable structural abnormalities. Correcting structural pathology with surgery leads to predictable and safe outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 10 - 10
13 Mar 2023
Rankin C Coleman S Robinson P Murray I Clement N
Full Access

We aim to determine the differences in lower limb joint kinematics during the golf swing of patients who had undergone Total Knee Arthroplasty (TKA) and a control group of native knee golfers.

A case-control study was undertaken with ten golfers who had undergone TKA (cruciate retaining single radius implant) and five age and matched golfers with native knees. Each golfer performed five swings with a driver whilst being recorded at 200Hz by a ten-camera motion capture system. Knee and hip three-dimensional joint angles (JA) and joint angular velocities (JAV) were calculated and statistically compared between the groups at six swing events.

The only significant differences in knee joint kinematics between TKA and control groups was a lower external rotation JA in the left knee during the backswing (p=0.010). There was no significant difference in knee JAV between the groups. Both hips demonstrated significantly (p=0.023 for left and p=0.037 for right) lower flexion in the TKA group during the takeaway swing event, and there was lower internal rotation in the backswing and greater external rotation in the downswing of the right hip. There was also slower left hip extension JAV in the downswing.

Normal knee kinematics were observed during the golf swing following TKA, with the exception of reduced external rotation in the left knee during the back swing and the right during the down swing. The differences demonstrated in the hip motion indicate that they may make compensatory movements to adjust to the reduced external rotation demonstrated in the knee.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 4 - 4
1 Oct 2021
Pleasant H Robinson P Robinson C Nicholson J
Full Access

Management of highly displaced acromioclavicular joint (ACJ) injuries remain contentious. It is unclear if delayed versus acute reconstruction has an increased risk of fixation failure and complications. The primary aim of this was to compare complications of early versus delayed reconstruction. The secondary aim was to determine modes of failure of ACJ reconstruction requiring revision surgery.

A retrospective study was performed of all patients who underwent operative reconstruction of ACJ injuries over a 10-year period (Rockwood III-V). Reconstruction was classed as early (<12 weeks from injury) or delayed (≥12 weeks). Patient demographics, fixation method and post-operative complications were noted, with one-year follow-up a minimum requirement for inclusion. Fixation failure was defined as loss of reduction requiring revision surgery.

104 patients were analysed (n=60 early and n=44 delayed). Mean age was 42.0 (SD 11.2, 17–70 years), 84.6% male and 16/104 were smokers. No difference was observed between fixation failure (p=0.39) or deep infection (p=0.13) with regards to acute versus delayed reconstruction. No patient demographic or timing of surgery was predictive of fixation failure on regression modelling. Overall, eleven patients underwent revision surgery for loss of reduction and implant failure (n=5 suture fatigue, n=2 endo-button escape, n=2 coracoid stress fracture and n=2 deep infection).

This study suggests that delayed ACJ reconstruction does not have a higher incidence of fixation failure or major complications compared to acute reconstruction. For those patients with ongoing pain and instability following a trial of non-operative treatment, delayed reconstruction would appear to be a safe treatment approach.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 11 - 11
1 Mar 2020
Murray I Robinson P Goudie E Duckworth A Clark K Robinson C
Full Access

This prospective, randomized, controlled trial compares patient outcome after non-operative care versus open reduction and tunneled suspension device fixation (ORTSD) for grade III or IV acromioclavicular joint disruptions.

Sixty patients aged between sixteen and thirty-five years with an acute grade III or IV AC joint disruption were randomized to receive ORTSD fixation or non-operative treatment. Functional assessment was conducted at six weeks, three months, six months, and one year using the Disabilities of the Arm, Shoulder and Hands (DASH), Oxford Shoulder Scores (OSS) and Short Form (SF-12). Reduction was evaluated using radiographs. Complications were recorded, and an economic evaluation performed.

There was no significant difference in DASH or OSS at one year between non-operative and ORTSD groups (DASH score, 4.67 versus 5.63; OSS, 45.72 versus 45.63). Patients undergoing surgery had inferior DASH scores at 6 weeks (p<0.01). Five patients who failed non-operative management subsequently received surgery. Overall cost of treatment was significantly greater after ORTSD fixation (£796.22 vs £3359.73 (p<0.01)).

ORTSD fixation confers no functional benefit over non-operative treatment at one year. While patients managed non-operatively generally recover faster, a significant group remain dissatisfied following non-operative treatment requiring delayed surgical reconstruction.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking.

We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months).

47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007).

This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 381 - 381
1 Sep 2012
Robinson P Harrison T Cook A Parker M
Full Access

Introduction

There has been little research into the effect of suffering a simultaneous hip and upper limb fragility fracture. The aim of this study is to describe the characteristics of this important group of patients and to define the effect on outcomes such as mortality and length of stay.

Materials and methods

Hip fracture data in our unit is collected prospectively and entered into a database. All study data was taken from this database. Patients under 60 years of age were excluded from the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 237 - 240
1 Feb 2012
Harrison T Robinson P Cook A Parker MJ

Prospective data on 6905 consecutive hip fracture patients at a district general hospital were analysed to identify the risk factors for the development of deep infection post-operatively. The main outcome measure was infection beneath the fascia lata.

A total of 50 patients (0.7%) had deep infection. Operations by consultants or a specialist hip fracture surgeon had half the rate of deep infection compared with junior grades (p = 0.01). Increased duration of anaesthesia was significantly associated with deep infection (p = 0.01). The method of fracture fixation was also significant. Intracapsular fractures treated with a hemiarthroplasty had seven times the rate of deep infection compared with those treated by internal fixation (p = 0.001). Extracapsular fractures treated with an extramedullary device had a deep infection rate of 0.78% compared with 0% for those treated with intramedullary devices (p = 0.02).

The management of hip fracture patients by a specialist hip fracture surgeon using appropriate fixation could significantly reduce the rate of deep infection and associated morbidity, along with extended hospitalisation and associated costs.