header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 71 - 71
1 Sep 2012
Hanratty B Thompson N Bennett D Robinson A Mullan C Beverland D
Full Access

Increasing knee flexion following total knee arthroplasty (TKA) has become an important outcome measure. Surgical technique is one factor that can influence knee motion. In this study, it was hypothesised that stripping of the posterior knee capsule could improve flexion and range of motion (ROM) following TKA. Patients who were undergoing TKA were prospectively randomised into two groups - one group (62 patients) were allocated stripping of the posterior knee capsule (PCS), the other group (66 patients) no stripping (no-PCS). The primary outcome was change in flexion and ROM compared to pre-operative measurements at three time points; after wound closure, 3months and 1year post-operatively. Secondary outcomes were absolute measurements of flexion, extension, ROM and complications. All operations were performed by a single surgeon using the same implant and technique. All patients received identical post-operative rehabilitation. There was a significant gain in flexion after wound closure in the PCS group (p=0.022), however there was no significant difference at 3months or 1year post-operatively. Absolute values of extension (p=0.008) and flexion (p=0.001) 3months post-operatively were significantly reduced for the PCS group. The absolute value of ROM was significantly higher for the no-PCS group at 3months (p=0.0002) and 1year (p=0.005). There were no significant difference in the rate of complications. Posterior capsular stripping causes a transient increase in flexion that does not persist post-operatively. We do not recommend routine stripping of the posterior knee capsule in patients undergoing TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 100 - 100
1 Feb 2012
Costa M Chester R Shepstone L Robinson A Donell S
Full Access

The aim of this study was to compare immediate weight-bearing mobilisation with traditional plaster casting in the rehabilitation of non-operatively treated Achilles tendon ruptures.

Forty-eight patients with Achilles tendon rupture were randomised into two groups. The treatment group was fitted with an off-the-shelf carbon-fibre orthotic and the patients were mobilised with immediate full weight-bearing. The control group was immobilised in traditional serial equinus plaster casts. The heel raise within the orthotic and the equinus position of the cast was reduced over a period of eight weeks and then the orthotic or cast was removed. Each patient followed the same rehabilitation protocol. The primary outcome measure was return to the patient's normal activity level as defined by the patient.

There was no statistical difference between the groups in terms of return to normal work [p=0.37] and sporting activity [p=0.63]. Nor was there any difference in terms of return to normal walking and stair climbing. There was weak evidence for improved early function in the treatment group.

There was 1 re-rupture of the tendon in each group and a further failure of healing in the control group. One patient in the control group died from a fatal pulmonary embolism secondary to a DVT in the ipsilateral leg.

Immediate weight-bearing mobilisation provides practical and functional advantages to patients treated non-operatively after Achilles tendon rupture. However, this study provides only weak evidence of faster rehabilitation.