Schröder M Windhagen H Calliess T Angrisani N Reifenrath J
Full Access

Aim

The aim of this study was to establish an implant-associated osteomyelitis model in rats with the ability to quantify biofilm formation on implants for prospective evaluation of antibacterial effects on micro-structured implant surfaces.

Method

Staphylococcus aureus (strain 36/07) suspension with infection concentrations of 106, 105, 104 and 103 CFU/10µl, respectively was injected in the tibia of 32 rats (n=8 per group). Afterwards a titanium implant (0.8×0.8×12 mm) was inserted. 8 rats were implanted with a preincubated implant (107 CFU/ml, 12 h) and 8 rats served as a control (injection of 0.9% NaCl). During the follow up, clinical, radiographic and µ-CT examinations were conducted. On day 21 post op, all rats were sacrificed. Implant and tibia were explanted under sterile conditions. The implant was stained with green and red fluorescent nucleic acid dye (live/ dead) and analyzed by confocal microscopy. The amount of vivid and dead biomass as well as vivid bacteria on the implant surface was calculated with an image software*.