Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis.

This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time.

860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001).

Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 62 - 62
4 Apr 2023
Rashid M Islam R Marsden S Trompeter A Teoh K
Full Access

A number of classification systems exist for posterior malleolus fractures of the ankle. The reliability of these classification systems remains unclear. The primary aim of this study was to evaluate the reliability of three commonly utilised fracture classification systems of the posterior malleolus.

60 patients across 2 hospitals sustaining an unstable ankle fracture with a posterior malleolus fragment were identified. All patients underwent radiographs and computed tomography of their injured ankle. 9 surgeons including pre-ST3 level, ST3-8 level, and consultant level applied the Haraguchi, Rammelt, and Mason & Molloy classifications to these patients, at two timepoints, at least 4 weeks apart. The order was randomised between assessments. Inter-rater reliability was assessed using Fleiss’ kappa and 95% confidence intervals (CI). Intra-rater reliability was assessed using Cohen's Kappa and standard error (SE).

Inter-rater reliability (Fleiss’ Kappa) was calculated for the Haraguchi classification as 0.522 (95% CI 0.490 – 0.553), for the Rammelt classification as 0.626 (95% CI 0.600 – 0.652), and the Mason & Molloy classification as 0.541 (95% CI 0.514 – 0.569). Intra-rater reliability (Cohen's Kappa) was 0.764 (SE 0.034) for the Haraguchi, 0.763 (SE 0.031) for the Rammelt, 0.688 (SE 0.035) for the Mason & Molloy classification.

This study reports the inter-rater and intra-rater reliability for three classification systems for posterior malleolus fractures. Based on definitions by Landis & Koch (1977), inter-rater reliability was rated as ‘moderate’ for the Haraguchi and Mason & Molloy classifications; and ‘substantial’ for the Rammelt classification. Similarly, the intra-rater reliability was rated as ‘substantial’ for all three classifications.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 63 - 63
4 Apr 2023
Rashid M Cunningham L Walton M Monga P Bale S Trail I
Full Access

The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up.

After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Society Score (ASES), and quick Disabilities of the Arm, Shoulder, and Hand Score (quickDASH). Radiographic assessment included AP and axial projections. Patients were invited to attend a CT scan to confirm osseointegration. Statistical analysis utilised included descriptive statistics (mean and standard deviation) and paired t test for parametric data.

3 patients had revision surgery prior to the 2-year follow-up. Of these, 2/3 retained their custom glenoid components. 4 patients declined to participate. 5 patients were deceased at the time of commencement of the study. 21 patients were included in this analysis. The mean follow-up was 36.1 months from surgery (range 22–60.2 months). OSS improved from a mean 16 (SD 9.1) to 36 (SD 11.5) (p < 0.001). Constant-Murley score improved from mean 9 (SD 9.2) to 50 (SD 16.4) (p < 0.001). QuickDASH improved from mean 67 (SD 24) to 26 (SD 27.2) (p = 0.004). ASES improved from mean 28 (SD 24.8) to 70 (SD 23.9) (p = 0.007). Radiographic evaluation demonstrated good osseointegration in all 21 included patients.

The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex patient cohort.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 33 - 33
1 Nov 2021
Hartland A Teoh K Rashid M
Full Access

Introduction and Objective

Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes.

Materials and Methods

This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 35 - 35
1 Nov 2021
Hartland A Islam R Teoh K Rashid M
Full Access

Introduction and Objective

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis.

Materials and Methods

This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 77 - 77
1 Apr 2017
Rashid M Aziz S Heydar S Fleming S Datta A
Full Access

Background

Radiation exposure remains a significant occupational hazard for Orthopaedic surgeons. There are no references values for trauma procedures performed with Image Intensifier (II). We aimed to determine and compare reference values for patient radiation exposure for common trauma operations, and to analyse the effect of surgeon grade on II usage.

Methods

Data collected prospectively from 849 cases between 01/05/2013 and 01/10/2014 were analysed. Statistical analysis was performed to calculate reference values for dose area product (DAP), screening time (ST), and number of II images taken for common trauma procedures where n>9 (n=808).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 1 - 1
1 Aug 2012
Shoaib A Rashid M Lahoti O Groom A Phillips S
Full Access

Objectives

Fracture non-union poses a significant challenge to treating orthopaedic surgeons. These patients often require multiple surgical procedures. The incidence of complications after Autologous Bone Graft (ABG) harvesting has been reported up to 44%. These complications include persistent severe donor site pain, infection, heterotopic ossification and antalgic gait. We retrospectively compared the use of BMP-7 alone in long bone fracture Non-union, with patients in whom BMP-7 was used in combination with the Autologous Bone Graft (ABG).

Material and Methods

The databases of our dedicated Limb Reconstruction Unit were searched for patient with three common long bone fractures Non-unions (Tibia, Femur and Humerus). The patients who had intra-operative use of Bone Morphogenetic Protein (BMP-7) alone and in combination with ABG were evaluated. 53 Patients had combined use of ABG and BMP-7, and 65 patients had BMP-7 alone.