Infection rates after management of open fractures are still high. Existing guidelines regarding prevention of this complication are inhomogeneous. A survey directed to orthopaedic trauma surgeons worldwide aims to give an overview of current practices in the management of open fractures. An international group of trauma surgeons and infection specialists with experience in the field of musculoskeletal infections developed a questionnaire that was distributed via email to all AOTrauma members worldwide. Descriptive statistical analysis was performed.Aim
Method
Open fractures still have a high risk for fracture-related Infection (FRI). The optimal duration of perioperative antibiotic prophylaxis (PAP) for open fractures remains controversial due to heterogeneous guidelines and highly variable prophylactic regimens in clinical practice. In order to provide further evidence with which to support the selection of antibiotic duration for open fracture care, we performed a preclinical evaluation in a contaminated rabbit fracture model. A complete humeral osteotomy in 18 rabbits was fixed with a 7-hole-LCP and inoculated with Aim
Method
Treatment regimens for fracture-related infection (FRI) often refer to the classification of Willenegger and Roth, which stratifies FRIs based on time of onset of symptoms. The classification includes early (<2 weeks), delayed (2–10 weeks) and late (>10 weeks) infections. Early infections are generally treated with debridement and systemic antibiotics but may not require implant removal. Delayed and late infections, in contrast, are believed to have a mature biofilm on the implant, and therefore, treatment often involves implant removal. This distinction between early and delayed infections has never been established in a controlled clinical or preclinical study. This study tested the hypothesis that early and delayed FRIs respond differently to treatment comprising implant retention. A complete humeral osteotomy in 16 rabbits was fixed with a 7-hole-LCP and inoculated with Aim
Method
The medial patellofemoral ligament (MPFL) has been recognised as the most important medial structure preventing lateral dislocation or subluxation of the patella (LeGrand 2007). After MPFL rupture the patella deviates from the optimal path resulting in an altered retropatellar pressure distribution. This may lead to an early degeneration with loss of function and need for endoprosthetic joint replacement. The goal of this study was to obtain first data about retropatellar pressure distribution under simulation of physiological quadriceps muscle loading and evaluate the influence of ligament instabilities. On ten fresh-frozen cadaveric knees the quadriceps muscle was divided into 5 parts along their anatomic fiber orientation analogous to Farahmand 1998. Muscular loading was achieved by applying weights to each of the five components in proportion to the cross sectional muscle area (total load 175 N). A custom made sensor was introduced between the patella and femur [Pliance, Novel / Germany]. The sensor consists of 85 single cells. The robot-control-unit is liked to a force-torque sensor. The force free knee-flexion-path from 0° to 90° was calculated during three “passive path” measurements. The actual measurements followed with identical parameters. At first, the retropatellar pressure distribution was recorded with intact ligaments (“native”). After cutting the MPFL the test was repeated. Then double bundle MPFL reconstruction (Schoettle 2009) was performed and the pressure distribution was obtained again. Minimum, mean and maximum pressures and forces were statistically compared in each of the three tested conditions (native Patella with intact MPFL, cut and reconstructed MPFL). We followed the hypothesis that MPFL reconstruction can restore native retropatellar pressure distribution.INTRODUCTION
MATERIALS AND METHOD
The medial patellofemoral ligament (MPFL) has been recognised as the most important medial structure preventing lateral dislocation or subluxation of the patella (LeGrand 2007). After MPFL rupture the patella deviates from the optimal path resulting in an altered retropatellar pressure distribution. This may lead to an early degeneration with loss of function and need for endoprosthetic joint replacement. The goal of this study was to develop a dynamic knee-simulator to test the influence of ligament instabilities to patella-tracking under simulation of physiological quadriceps muscle loading. On 10 fresh-frozen cadaveric knees the quadriceps muscle was divided into five parts along their anatomic fibre orientation analogous to Farahmand 1998. The muscular loading was achieved by applying weights to each of the fife components in proportion to the cross sectional muscle area. A total of 175 N was connected to the muscles using modified industrial cable connecting systems [Lancier Calbe, Drensteinfurt/Germany]. A novel light digital patellar reference base (DRB) was developed and attached to the patella with four bone screws. On addition a femoral and tibial digital reference base was constructed and secured to these two bones. Position data of the patella, the femur and tibia was tracked by a conventional tracking system [Optotrak, NDI Europe]. The relative movement between femur and tibia (“flexion path”) and patella and femur (“patella tracking”) was recorded. For retropatellar pressure measurement a custom made sensor was introduced between the patella and femur [Pliance, Novel/Germany]. The sensor consists of 85 single pressure measuring cells. The robot-control-unit is liked to a force-torque sensor (hybrid method). The force free knee-flexion-path from 0° to 90° was calculated during three “passive path” measurements using this hybrid robotic method. The actual measurements followed with identical parameters. The 3D-patella position was recorded (six degrees of freedom) along with the corresponding retropatellar pressure distribution according to knee-flexion and medial forces (intact vs. cut MPFL). Measurements were performed for the intact knee (“native”), with muscular quadriceps loading, after opening the joint capsule and with introduced pressure sensor to differentiate each of their influences. The load free knee-flexion-path (“passive path”) could be calculated for all of the ten knees and was utilised as the basis for all dynamic measurements. There was no alteration of the “flexion-path”. Thus the measurements were only influenced by the variables “capsular joint opening,” “muscular quadriceps loading” and “MPFL-tension”. The custom made connections between the five quadriceps components and weights proved to be a secure way to prevent rupture due to the applied forces of up to 70 N during the average measuring time of 7.5 h/knee. Only on one knee the Vastus lateralis obliquus muscle ruptured proximally. All reference bases were 100% visible despite the knee flexion form 0°–90°. No loosening of the reference base screws occurred. Overall the combination of a robotic-assisted, force free dynamic knee-flexion under quadriceps simulation and 3D-patella-tracking seems to be a promising method to evaluate the biomechanical influences of ligaments on the human knee.
A major pathway of closed soft-tissue injury is failure of microvascular perfusion combined with a persistently enhanced inflammatory response. We therefore tested the hypothesis that hypertonic hydroxyethyl starch (HS/HES) effectively restores microcirculation and reduces leukocyte adherence after closed soft-tissue injury. We induced closed soft-tissue injury in the hindlimbs of 14 male isoflurane-anaesthetised rats. Seven traumatised animals received 7.5% sodium chloride-6% HS/HES and seven isovolaemic 0.9% saline (NS). Six non-injured animals did not receive any additional fluid and acted as a control group. The microcirculation of the extensor digitorum longus muscle (EDL) was quantitatively analysed two hours after trauma using intravital microscopy and laser Doppler flowmetry, i.e. erythrocyte flux. Oedema was assessed by the wet-to-dry-weight ratio of the EDL. In NS-treated animals closed soft-tissue injury resulted in massive reduction of functional capillary density (FCD) and a marked increase in microvascular permeability and leukocyte-endothelial cell interaction as compared with the control group. By contrast, HS/HES was effective in restoring the FCD to 94% of values found in the control group. In addition, leukocyte rolling decreased almost to control levels and leukocyte adherence was found to be reduced by ~50%. Erythrocyte flux in NS-treated animals decreased to 90 ± 8% (mean HS/HES effectively restores nutritive perfusion, decreases leukocyte adherence, improves endothelial integrity and attenuates oedema, thereby restricting tissue damage evolving secondary to closed soft-tissue injury. It appears to be an effective intervention, supporting nutritional blood flow by reducing trauma-induced microvascular dysfunction.