header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 507 - 515
1 Apr 2018
Nnadi C Thakar C Wilson-MacDonald J Milner P Rao A Mayers D Fairbank J Subramanian T

Aims

The primary aim of this study was to evaluate the performance and safety of magnetically controlled growth rods in the treatment of early onset scoliosis. Secondary aims were to evaluate the clinical outcome, the rate of further surgery, the rate of complications, and the durability of correction.

Patients and Methods

We undertook an observational prospective cohort study of children with early onset scoliosis, who were recruited over a one-year period and followed up for a minimum of two years. Magnetically controlled rods were introduced in a standardized manner with distractions performed three-monthly thereafter. Adverse events which were both related and unrelated to the device were recorded. Ten children, for whom relevant key data points (such as demographic information, growth parameters, Cobb angles, and functional outcomes) were available, were recruited and followed up over the period of the study. There were five boys and five girls. Their mean age was 6.2 years (2.5 to 10).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 71 - 71
1 Apr 2012
Vollans S Michael A Rao A
Full Access

To evaluate and describe the plain radiographic changes observed with time in fusions using SiS-CaP. We describe, for the first time, 4 stages of bone substitute fusion mass (BSFM) radiographic appearance in relation to time post-op.

Retrospective, radiological evaluation.

Over 200 plain radiographs were evaluated. 70 consecutive fusions for degenerative spinal stenosis were included, in all cases performed by the same surgeon using the same operative technique. Follow-up was from 3 months to 2 years post-op.

Radiographs were evaluated for the presence or absence of SiS-CaP granules, bone formation and for evidence of pseudarthrosis.

Trends were seen within the BSFM with respect to time. At 6-12 weeks post-op a ‘homogenous granular stage’ indicates the presence of the unchanged SiS-CaP.

At 12 weeks, small pockets appear within the BSFM in the ‘vacuolation stage’, indicating bioresorption of the graft. Vacuoles become increasingly radio-opaque indicating bone proliferation during the ‘homogenous lamellar stage’. At variable time between 6 months and 2 years, the BSFM becomes encapsulated in the ‘cortication stage’ visible as a sclerotic rim around the BSFM.

We have seen a clear trend in the behaviour of the fusion mass in this case series. The radiological stages we have described above can be closely correlated with previously reported in-vitro and in-vivo studies looking at the micro-function of SiS-CaP. We hope that this description will help to judge the progress of graft incorporation and fusion. Further study of inter and intra-observer correlation will be required.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 62 - 62
1 Apr 2012
Michael A Tiyagi A Rao A
Full Access

To report on the management of a patient with grade 1 holocord pilocytic astrocytoma and scoliosis.

Case report of a rare spinal cord tumour and a management of the scoliosis.

An 11 year boy complained of gradually worsening neck, back pain and pain in all limbs. This was accompanied by unsteadiness, weakness of lower limbs and bed wetting of recent onset. There was a family history of spinal cord tumour.

Examination revealed signs of spinal cord compression and a left thoracic scoliosis. Magnetic resonance imaging showed an intra-medullary tumour extending through the spinal cord and syrinx formation.

He underwent T1-3 approach for drainage of syrinx, biopsy of tumour and laminoplasty with plates. He was started on chemotherapy for 14 months. During this period a syringo-peritoneal shunt was inserted. There was further growth of the tumour and neurological deterioration. He subsequently underwent T8-L1 laminoplasty, debulking of tumour and insertion of dual diameter growing rods.

There has been no significant neurological deterioration. There was good correction of the scoliosis with Cobb angle reducing from 50 to 15 degrees. Lengthening of growing rods has been done 4 times with good length achieved.

Excision of tumour and growing rod insertion (not previously reported) is a good way of controlling neurological symptoms and the scoliosis in this rare spinal cord tumour.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 63 - 63
1 Apr 2012
Michael A Vollans S Rankine J Rao A
Full Access

To assess radiological fusion rates in posterolateral fusions using SiS-CaP.

Retrospective, radiological follow-up study.

Single surgeon series of 76 consecutive patients were evaluated, in a regional spinal unit. All patients had clinical and radiological (MRI) spinal canal stenosis secondary to degenerative spondylosis or spondylolisthesis. Surgery consisted of instrumentation, decompression and meticulous preparation of the posterolateral graft bed by removal of all soft tissues posterior to the inter-transverse membrane and decortication of transverse processes (TPs). SiS-CaP putty was injected into this gutter and moulded around the instrumentation. Good quality, well prepared bone chips from the posterior decompression were seeded into the putty. Patient radiographs were reviewed at 3-6 months, 1 year and 2 years.

Radiographs were assessed using a protocol to examine granularity, bone formation and evidence of pseudarthrosis, based upon previously reported literature 1 and our personal experience.

Of the 76 patients, 26 were excluded. M:F was 21:29. Mean age was 58yrs. Average number of motion segments fused per case was 2.2. There was one pseudarthrosis with metalwork fracture, and thus a total fusion rate of 98%. In addition, one patient had scanty bridging of TPs, and one patient had lucency around the S1 screws.

SiS-CaP, as a bone graft substitute in posterolateral instrumented fusions, gives comparable results to published fusion rates using autologous iliac crest grafting and/or Bone Morphogenic Protein 2. Moreover, it avoids the associated morbidity of iliac bone harvest.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 91 - 91
1 Apr 2012
Pai S Michael R Rao A Dunsmuir R Millner P
Full Access

To evaluate the efficacy of Vacuum Assisted Closure (VAC) in the management of post surgical spinal sepsis.

A retrospective analysis was performed of patients with severe post operative spinal wound infections treated using a combination surgical debridement, antibiotics and VAC therapy.

Full records were available for a total of twenty adult all of whom had had prior thoracic or lumbar instrumentation. Comorbidities included disseminated carcinomatosis (25 % of patients), Ankylosing spondylitis (5 %), rheumatoid arthritis (5%) and Polio (5%). In one patient there had been a prior history of irradiation of the surgical field. Most infections treated by this regime were identified within two weeks following surgery. At surgery infection deep to the dorso-lumbar fascia was found in 87 % of cases. It was possible to retain instrumentation in 60 % of cases. An average of three trips to theatre were required prior to wound closure, which was possible in 95 % of cases. The VAC device was left in situ for an average of 11 days. Complications included recurrence of infection necessitating further treatment in 20 % of cases, wound dehiscence necessitating healing by secondary intention in 5%, the need for free flap wound cover in 5 % and death from unrelated causes in 5%.

VAC therapy may facilitate the management of wound sepsis following spinal surgery in susceptible patients allowing the maintenance of instrumentation and surgical correction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 64 - 64
1 Apr 2012
Michael A Loughenbury P Dunsmuir R Rao A Millner P
Full Access

To determine the current practice of scoliosis surgery in the UK.

A 10 point questionnaire was constructed to identify the philosophy of surgeons on various aspects of scoliosis surgery such as choice of implant, bone graft, autologous blood transfusion (ABT), cord monitoring and computer assisted surgery. Results are compared with the current best evidence.

Consultants and Fellows attending the 2009 British Scoliosis Society meeting. 50 questionnaires were completed: 45 Consultants and 5 Fellows.

All pedicle screw construct favored by 25/50, hybrid 24/50 (one undecided). Posterior construct of less than 10 levels, 20/50 would not cross-link, 11/50 used one and 19/20 used two or more. More than ten levels 17/50 considered cross-links unnecessary, 4/50 used one and 29/50 used two or more. 88% preferred titanium alloy implants, while a mixture of stainless steel and cobalt chrome was used by others. For bone graft, substitutes (24), iliac crest (14), allograft (12) and demineralised bone matrix (9) in addition to local bone. 10/50 would use recombinant bone morphogenetic protein (3 for revision cases only). 39/50 routinely used intra-operative cell salvage or ABT drains and 4/50 never used autologous blood. All used cord monitoring, Sensory (19/50), Motor (2/50) and combined (29/50). None used computer-aided surgery. 26 operated alone 12 operated in pairs and 12 varied depending on type of case.

This survey has brought to light interesting variations in scoliosis surgery in UK. It may reflect the conflicting evidence in the literature.