Vol. 98-B, Issue SUPP_13 | Pages 2 - 2
1 Jun 2016
Ramesh R Smith C
Full Access

Following the recognition of platelet rich plasma (PRP) as an interventional procedure by NICE, patients who had failed standard conservative treatment for chronic elbow tendinitis and referred for surgery were recruited prospectively into a PRP injection study.

52 patients at Torbay Hospital, Devon, UK received PRP injections in 18 months and 37 had a minimum of 6 months follow up. The outcomes in these patients are summarised.

There were 16 males and 21 females. 30 had tennis elbow and 7 had golfers elbow. All patients had their symptoms for a minimum of 6 months and had failed to improve with standard conservative treatment. 2 had a failed outcome from previous tennis elbow release surgery. The PRP injections were carried out under ultrasound guidance after correlating the tender spot with neovascularisation on flow Doppler. 31 patients had a single injection; the other 21 patients had 2 injections. Quick DASH score and patients own self-satisfaction was used to measure outcome. 18 patients (48%) were discharged by 6 months. DASH score worsened in 7 patients (19%) and 2 of these patients opted to have surgery, which had no benefit either. No complications were observed with the use of PRP.

Overall, by using PRP injections, surgery was avoided in 35 patients (95%) at 18 months and nearly half of the patients were discharged from follow up by 6 months.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 9 - 9
1 Apr 2013
Kosy J Bradley BM Hawken R Ramesh R Conboy V
Full Access

The use of scoring systems for surveillance of post-operative outcomes is increasing. However, the methodology of this follow-up is not universal. We set out to assess whether a postal Oxford Shoulder Score (OSS) was sufficient to identify patients who were dissatisfied and wanted further treatment.

Of 88 patients who had undergone GlobalCap resurfacing in the previous 5 years, we received a completed postal OSS (Median score 33, Range 5–48) from 80 patients. Those with a score <24 (an agreed threshold for surgery pre-operatively) were brought to clinic for review.

The 16 recalled patients (2 males, 14 females; age 58–85) had their OSS repeated, supervised by a clinic nurse, and had a Constant Score and an American Shoulder and Elbow Surgeons (ASES) Score performed. Satisfaction was also questioned.

OSS correlated well with the Constant Score (r=0.79) and ASES (r=0.86). However, supervision increased the OSS by an average of 6 points (Mean 13.9 to 19.9) and only three of the patients proved dissatisfied with the outcome of their surgery.

Used alone, an unobserved OSS may have limited value for this purpose and the use of comparative pre-operative scores or additional patient-reported outcome measures may be necessary to detect poor outcomes.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 31 - 31
1 Feb 2013
Kassam A Ainsworth B Hawken R Ramesh R Conboy V
Full Access

Patients using a neutral rotation brace post proximal humerus fracture fixation have improved functional outcome and external rotation of the shoulder compared to patients using a standard polysling.

Patients who have proximal humerus fracture fixation with extramedullary plates and screws have a risk of reduced range of movement especially external rotation. Gerber et al showed that the average external rotation after fixation of proximal humeral fractures was 39 degrees in their patient cohort compared to a normal range of 80–100 degrees. This can lead to reduced function and poor patient related outcomes. Geiger et al showed that in a cohort of 28 patients, poor functional outcome was noted in 39.3% with an average Constant-Murley Score of 57.9.

Current practice is to utilise a polysling holding the shoulder in internal rotation post-shoulder fixation. Patients usually wear the sling for up to 6 weeks. We believe that this increases the risk of adhesion formation with the shoulder in internal rotation in the shoulder joint. Therefore this can cause loss of external rotation in the shoulder joint. We believe that holding the shoulder in a neutral alignment, with a neutral rotation brace post-fixation, will enable an increased rate of external rotation post-operatively thus improving external rotation and functional outcome

There is currently no literature comparing the different slings used post-operatively and we believe that this study would be the first of its kind. It would have a substantial change in the way clinicians manage proximal humeral fractures and will potentially reduce the numbers of re-operations to divide adhesions or perform capsular releases. Secondary benefits include a potential earlier return to full function and work and improved patient satisfaction.

Study proposal: Prospective Randomised Controlled Trial of the neutral rotation brace compared to the standard, currently used, polysling post proximal humerus fracture fixation. No blinding of either participants or clinicians. Three surgeons utilising similar fixation techniques via the deltopectoral approach and using Philos plate fixation (Synthes Ltd.). Standardised post-operative rehabilitation protocol for all patients.

Follow up: clinical review and postal outcomes for 1 year

Primary outcomes: Post operative functional outcome scores (Oxford, DASH, EQL) obtained at 6 weeks, 9 weeks, 3 months and 1 year). These will be compared to scores taken pre-operatively.

Secondary outcomes: Clinical review at 6 weeks, 3 months and 1 year with range of movement measurements. Radiographs also taken at 6 weeks and 3 months to assess union. Patient questionnaire at 1 year (with outcome scores) assessing patient return to work, complications and patient satisfaction

Inclusion criteria: Proximal humeral fractures requiring operative intervention with extramedullary plate fixation (i.e. fractures displaced by 1cm and/or angulated by 45 degrees or more). Age>18.

Exclusion Criteria: Patients having intra-operative findings of complete Pectoralis major rupture or if operative exposure requires complete Pectoralis major tenotomy. (These patients need to be held in internal rotation with a standard polysling to allow healing of the Pectoralis major tendon).