Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 144 - 144
1 Mar 2012
Davis N Powell-Smith E Phillips S Hobby J Lowdon I
Full Access

Introduction

PIPJ replacement has become increasingly popular however, there is very little clinical data available apart from small studies and those from the originators of the prostheses. We present a review of our initial experience with the Acension(c) Pyro-carbon PIP joint.

Results

Data was collected from 62 joints in 39 patients with one patient lost to follow-up. Mean age was 61.6 years. 29 patients were female and 10 male. Mean follow up was 22.3 months (range 11 to 54). 7 patients or 11% needed further surgery. The majority were for stiffness with 3 operations for dislocation or component malposition. The total complication rate was 32%, again the biggest problem was stiffness. 4 joints have subluxed or dislocated, 2 had superficial infections. There was no statistical difference in the rate of complications compared to the operated finger or the pre-operative diagnosis.

Post-operatively patients had a mean fixed flexion deformity of 19° and flexed to 76° (58° arc). However patients undergoing surgery following trauma do not do as well as the other groups with a decrease in ROM of 33°.