Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 46 - 46
1 Oct 2022
Porcellini G Giorgini A Montanari M
Full Access

Aim

Studies have shown that retention of antibiotic cement spacer in selected elderly patients with low functional demand represents a viable option for periprosthetic joint infections (PJI) treatment1,2.

The aim of this study is to compare the efficacy in infection treating among modular taylored preformed and hand-made antibiotic spacers. Our hypothesis is that modular tailored preformed spacer provides a better rate of infection resolution, better radiological and functional outcomes compared to hand-made spacers.

Materials and methods

We identified 48 patients treated with antibiotic cement spacer for shoulder chronic infection between 2015 and 2021 in our institution; (13 hand-made spacers and 35 modular tailored preformed spacers). We collected data about comorbidities, associated microorganism, infection resolution, clinical and radiographic evaluation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 8 - 8
1 Jun 2021
Giorgini A Tarallo L Porcellini G Micheloni G
Full Access

Introduction

Reverse shoulder Arthroplasty is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. Several new technology has been developed the improve the implant positioning. CT-based intraoperative navigation system is a suitable technology that allow the surgeon to prepare the implant site exactly as planned with preoperative software.

Method

Thirty reverse shoulder prostheses were performed at Modena Polyclinic using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). Walch classification was used to assess glenoid type. Planned version and inclination of the glenoid component, planned seating, final version and inclination of the reamer were recorded. Intraoperative and perioperative complication were recorded. Planned positioning was conducted aiming to the maximum seating, avoiding retroversion >10° and superior inclination.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 40 - 40
1 Feb 2020
Tarallo L Porcellini G Giorgini A Pellegrini A Catani F
Full Access

Introduction

Total shoulder replacement is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. CT-based intraoperative navigation system is a suitable option to improve accuracy and precision of the implants as previously described in literature for others district.

Method

Eleven reverse shoulder prostheses were performed at Modena Polyclinic from October 2018 to April 2019 using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). In the preoperative planning, Walch classification was used to assess glenoid type. The choice of inclination of the glenoid component, the screw length, as well as the inclination of the reamer was study and recorded using specific software using the CT scan of shoulder of each patient (Fig.1, Fig.2). Intraoperative and perioperative complications were recorded. Three patients were male, eight were female. Mean age was 72 years old (range 58=84). Three glenoid were type B2, six cases were B1, two case were type C1.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 75 - 80
1 Jan 2016
Merolla G Chin P Sasyniuk TM Paladini P Porcellini G

Aims

We evaluated clinical and radiographic outcomes of total shoulder arthroplasty (TSA) using the second-generation Trabecular Metal (TM) Glenoid component. The first generation component was withdrawn in 2005 after a series of failures were reported. Between 2009 and 2012, 40 consecutive patients with unilateral TSA using the second-generation component were enrolled in this clinical study. The mean age of the patients was 63.8 years (40 to 75) and the mean follow-up was 38 months (24 to 42).

Methods

Patients were evaluated using the Constant score (CS), the American Shoulder and Elbow Surgeons (ASES) score and routine radiographs.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 574 - 574
1 Oct 2010
Porcellini G Campi F Lollino N Paladini P Pegreffi F
Full Access

Aims: Displaced proximal humeral fractures are considered a real challenge. Malunion, nonunion, avascular necrosis, arthritis are frequent complications. Thus revision surgery, using reverse shoulder prosthesis, is mandatory both to restore shoulder function and to relieve pain.

Our purpose was to understand if clinical outcomes after revision surgery are influenced by the first surgical procedure performed to fix the fracture.

Methods: 15 patients, mean age 67±2 yrs, sustained a complex humeral fracture. Group A (8 patients) was treated with reduction and fixation with K-wires, while in Group B (7 patients) a cemented hemiarthroplasty was performed. After primary surgical treatment, both groups required revision surgery and a shoulder reverse prosthesis was implanted.

Constant score, Flexion, VAS scale and Dash questionnaire were evaluated preoperatively and at 1 year after revision surgery,

Results: Constant Score improved from 7 to 42 points in Group A, while in Group B from 15 to 41 points (n.s.). Flexion in Group A improved from 30° to 106°, while in Group B from 44° to 94° (n.s.). VAS value decreased from 9 to 2 in Group A and from 8 to 5 in Group B (n.s.). Dash value decreased from 82 to 49 points in Group A and from 75 to 55 points in Group B (n.s.).

Conclusions: This study demonstrates that reverse shoulder prosthesis offers a salvage-type solution in revision surgery reguardless the surgical treatmet performed previously. In conclusion reverse shoulder prosthesis is an important tool the surgeon can use in shoulder revision surgery.