Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims

The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs).

Methods

This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1392 - 1395
1 Oct 2014
Dhinsa BS Gregory JJ Nawabi DH Khan S Pollock R Aston WJ Skinner JA Briggs TWR

In patients with a tumour affecting the distal ulna it is difficult to preserve the function of the wrist following extensive local resection. We report the outcome of 12 patients (nine female, three male) who underwent excision of the distal ulna without local soft-tissue reconstruction. In six patients, an aggressive benign tumour was present and six had a malignant tumour. At a mean follow-up of 64 months (15 to 132) the mean Musculoskeletal Tumour score was 64% (40% to 93%) and the mean DASH score was 35 (10 to 80). The radiological appearances were satisfactory in most patients. Local recurrence occurred in one patient with benign disease and two with malignant disease. The functional outcome was thus satisfactory at a mean follow-up in excess of five years, with a relatively low rate of complications. The authors conclude that complex reconstructive soft-tissue procedures may not be needed in these patients.

Cite this article: Bone Joint J 2014;96-B:1392–5.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 250 - 253
1 Feb 2013
Jalgaonkar A Dawson-Bowling SJ Mohan AT Spiegelberg B Saifuddin A Pollock R Skinner JA Briggs TWR Aston W

Local recurrence along the biopsy track is a known complication of percutaneous needle biopsy of malignant musculoskeletal tumours. In order to completely excise the track with the tumour its identification is essential, but this becomes increasingly difficult over time. In an initial prospective study, 22 of 45 patients (48.8%) identified over a three-month period, treated by resection of a musculoskeletal tumour, had an unidentifiable biopsy site at operation, with identification statistically more difficult after 50 days. We therefore introduced the practice of marking the biopsy site with India ink. In all 55 patients undergoing this procedure, the biopsy track was identified pre-operatively (100%); this difference was statistically significant. We recommend this technique as a safe, easy and accurate means of ensuring adequate excision of the biopsy track.

Cite this article: Bone Joint J 2013;95-B:250–3.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 17 - 17
1 Jul 2012
Picardo N Blunn G Shekkeris A Aston W Pollock R Meswania J Cannon S Skinner J Briggs T
Full Access

Introduction

Following bone tumour resection, lower limb reconstruction results in leg-length discrepancy in skeletally immature patients. Previously, minimally invasive endoprostheses have been associated with a high risk of complications including joint stiffness, nerve injury, aseptic loosening and infection. The purpose of this study was to examine the outcome of the Stanmore non-invasive extendible endoprostheses used in our institution between 2002 and 2009 and compare them with implants used in the past.

Methods

Fifty-five children with a mean age of 11.4 years (5 to 16) underwent limb reconstruction with thirty-three distal femoral, two total femoral, eight proximal femoral and twelve proximal tibial implants. Forty-six endoprostheses were lengthened in clinic without anaesthesia using the principle of electromagnetic induction. Patients were assessed using the Musculoskeletal Tumour Society Score (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 40 - 40
1 Jul 2012
Sabharwal S Datta G Berber O Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Introduction

The proximity of the superior tibiofibular articulation to neurovascular structures makes the management of extraosseous tumours of the proximal fibula challenging in bone tumour surgery. The aim of study is to establish whether the recurrence rates are higher in this anatomical area compared to data that already exists in publication for bone tumours throughout the appendicular skeleton.

Method

A retrospective study of all patients treated for Ewing's tumours and osteosarcoma at a regional bone tumour unit between January 1995 and December 2009 was conducted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 6 - 6
1 Jul 2012
Shekkeris A Pollock R Aston W Cannon S Blunn G Skinner J Briggs T
Full Access

Introduction

Primary bone tumours of the distal radius are rare, while it remains the third commonest site for primary lesions and recurrences of Giant Cell Tumours (GCT). The functional demands on the hand make reconstruction of the wrist joint following the excision of distal radius, particularly challenging.

Methods

A single-centre retrospective study, reporting the functional and oncological outcomes of six patients (4 males, 2 females - mean age of 53 (22 to 79)) who underwent a custom-made endoprosthetic replacement of the distal radius with arthrodesis at our institution, during 1999 - 2010. Five patients were diagnosed with primary bone sarcoma of the distal radius (4 GCTs, 1 osteosarcoma) and another had a metastatic lesion from a primary renal cell carcinoma. The diagnosis was confirmed by needle biopsy in all cases.

We assessed the patients' functional outcomes using the Musculoskeletal Tumour Society scoring system (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 16 - 16
1 Jul 2012
Perera J Gikas P Griffiths D Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 399 - 403
1 Mar 2011
Griffiths D Gikas PD Jowett C Bayliss L Aston W Skinner J Cannon S Blunn G Briggs TWR Pollock R

Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%).

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18).

Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1134 - 1137
1 Aug 2010
Kalson NS Gikas PD Aston W Miles J Blunn G Pollock R Skinner J Briggs TWR Cannon SR

Disarticulation of the hip in patients with high-grade tumours in the upper thigh results in significant morbidity. In patients with no disease of the proximal soft tissue a femoral stump may be preserved, leaving a fulcrum for movement and weight-bearing. We reviewed nine patients in whom the oncological decision would normally be to disarticulate, but who were treated by implantation of an endoprosthesis in order to create a functioning femoral stump. The surgery was undertaken for chondrosarcoma in four patients, pleomorphic sarcoma in three, osteosarcoma in one and fibrous dysplasia in one. At follow-up at a mean of 80 months (34 to 132), seven patients were alive and free from disease, one had died from lung metastases and another from a myocardial infarction. The mean functional outcome assessment was 50 (musculoskeletal tumor society), 50 and 60 (physical and mental Short-form 36 scores).

Implantation of an endoprosthesis into the stump in carefully selected patients allows fitting of an above-knee prosthesis and improves wellbeing and the functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee.

In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1504 - 1508
1 Nov 2007
Bhadra AK Pollock R Tirabosco RP Skinner JAM Cannon SR Briggs TWR Flanagan AM

Four patients who developed malignant synovial tumours are described; one with chondromatosis developed a synovial chondrosarcoma and three with pigmented villonodular synovitis developed malignant change. The relevant literature is discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1367 - 1372
1 Oct 2006
Gupta A Pollock R Cannon SR Briggs TWR Skinner J Blunn G

We used a knee-sparing distal femoral endoprosthesis in young patients with malignant bone tumours of the distal femur in whom it was possible to resect the tumour and to preserve the distal femoral condyles. The proximal shaft of the endoprosthesis had a coated hydroxyapatite collar, while the distal end had hydroxyapatite-coated extracortical plates to secure it to the small residual femoral condylar fragment. We reviewed the preliminary results of this endoprosthesis in eight patients with primary bone tumours of the distal femur. Their mean age at surgery was 17.years (14 to 21). The mean follow-up was 24 months (20 to 31). At final follow-up the mean flexion at the knee was 102° (20° to 120°) and the mean Musculoskeletal Tumour Society score was 80% (57% to 96.7%).

There was excellent osteointegration at the prosthesis-proximal bone interface with formation of new bone around the hydroxyapatite collar. The prosthesis allowed preservation of the knee and achieved a good functional result. Formation of new bone and remodelling at the interface make the implant more secure. Further follow-up is required to determine the long-term structural integrity of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 649 - 654
1 May 2006
Gupta A Meswania J Pollock R Cannon SR Briggs TWR Taylor S Blunn G

We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality.