Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2006
Malik A Nicols S Pearse M Bitsakos C Amis A Phillips C Radford W Banks L
Full Access

Aim: A study to compare bone remodeling (BMD changes) around the femoral component of a cemented and uncemented THR using DXA scan and Finite element analysis and to check the predictive value of remodelling simulations as a pre-clinical implant testing tool.

Methods: Twenty patients were recruited, ten for each implant type (Exeter and ABG-II). All volunteers underwent unilateral hip replacement. No patient had any metabolic bone disease or were on medication that would alter BMD. Each patient had a preopera-tive CT scan of the hip, in order to provide 3D bone shape and density data needed to construct a computer model. Each patient’s changes of BMD over a period of 12 months postoperatively were evaluated in a series of 4 follow-up DXA scans taken at 3 weeks, 3, 6 and 12 months post-op. For the computer simulation, Finite Element (FE) models of the affected femur were constructed for each patient and BMD changes predicted using strain adaptive bone remodelling theory. These patients were clinical followed up to access the hip scores (Merle d’Aubigne Postel)

Results: All the patients were Charnely group A and had excellent postoperative hip scores (average pain 5.5, walking 5.4 and range of motion 5.3) The Exeter stem DXA results show bone resorption in Gruen zone 3 (2.8% on average) and 4 (3.3%) whereas there is a tendency for bone deposition at regions 1, 6 and 7 (2% on average). The ABG-II stem results show bone resorption developing at regions 7 and 4 (6% and 2% respectively) and some bone formation at region 6 (2%). The simulation results have a tendency to overestimate amounts of bone resorption (20% at region 7 for the ABG-II, 12% at region 3 for the Exeter).

Conclusion: A comparison of the remodelling around a cemented and a non-cemented hip implant show important differences in the emerging patterns of adaptation. To our knowledge, very few published studies provide information on bone remodelling around cemented stems, and compare the results to those of an uncemented stem. Additionally, the simulation results suggest that these formulations can reproduce realistic patterns of bone adaptation. This study aims at providing the means for comparison and subsequent improvement of the accuracy of the simulations and thus helps develop a hip prosthesis that would led to least bone resorption.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 73 - 76
1 Jan 1997
Nutton RW McBirnie JM Phillips C

We report a prospective study of 49 patients who had arthroscopic subacromial decompression for chronic rotator-cuff impingement. All patients were assessed preoperatively and at 3, 6 and 12 months using the modified UCLA shoulder score.

The dominant arm was affected in 35 patients, but only 13 recognised overuse as a cause of their shoulder pain. Before operation, the UCLA shoulder score was poor or fair in all patients. After three months only 28% of patients had satisfactory relief of symptoms but at one year 85% of patients examined had a good or excellent result. Patients with calcific tendonitis recovered more quickly: 93% reported a good result at six months.

We conclude that arthroscopic subacromial decompression is an effective form of treatment, but that patients should be warned that recovery from surgery may be prolonged.