The National Hip Fracture Database (NHFD) is a clinically led web based audit used to inform national policy guidelines. The aim of this audit was to establish the accuracy of completion of NHFD v13.0 theatre collection sheets, identify common pitfalls and areas of good practice, whilst raising awareness of the importance of accuracy of this data and the manner in which it reflects performance of CAH Trauma & Orthopaedic unit in relation to national guidelines. Our aim was to improve completion up to >80% by the operating surgeon and improve overall accuracy. The methodology within both cycles of the audit were identical. It involved reviewing the NHFD V13.0 completed by the operating surgeon and cross-checking their accuracy against clinical notes, operation notes, imaging, anaesthetic charts and A&E admission assessment. Following completion of cycle 1 these results were presented, and education surrounding V13.0 was provided, at the monthly trust audit meeting. At this point we introduced a sticker onto the pre-operative checklist for Hip fractures. This included time of admission and reason for delay. We then completed a re-audit. Cycle-1 included 25 operations, 56% (n=14) had a completed V13.0 form. Of these 21% (n=3) were deemed to be 100% accurate. Cycle-2 included 31 operations (between April – June 21) 81% (n=25) had a completed intra-operative from and showed an increase in accuracy to 56% (n=14) Through raising awareness, education and our interventions we have seen a significant improvement in the completion and accuracy of v13.0. Although 100% accuracy was not achieved its clear that education and intervention will improve compliance over time. Through the interventions that we have implemented we have shown that it is possible to improve completion and accuracy of the NHFD V13.0 theatre collection sheet locally and feel this could be implemented nationally.
Vancouver B fractures around a cemented polished tapered stem (CTPS) are often treated with revision arthroplasty. Results of osteosynthesis in these fractures are poor as per current literature. However, the available literature does not distinguish between fractures around CTPS from those around other stems. The aim of our study was to assess the clinical and radiological outcome of open reduction and internal fixation in Vancouver B fractures around CTPS using a broad non-locking plate. Patients treated with osteosynthesis between January 1997 and July 2011 were retrospectively reviewed. All underwent direct reduction and stabilisation using cerclage wires before definitive fixation with a broad DCP. Bicortical screw fixation was obtained in the proximal and distal fragments. We defined failure of treatment as revision for any cause. 101 patients (42 men and 59 women, mean age 79) were included. 70 had minimum follow-up of 6 months. 63 of these went on to clinical and radiological union. Three developed infected non-union. 7 had failure of fixation. Lack of anatomical reduction was the commonest predictor of failure followed by inadequate proximal fragment fixation and infection. 14 patients dropped at least 1 mobility grade from their preoperative status. This is the largest series of a very specific group of periprosthetic fractures treated with osteosynthesis. Patients who develop these fractures are often frail and “high risk” for major revision surgery. We recommend osteosynthesis for patients with Vancouver B periprosthetic fractures around CTPS provided these fractures can be anatomically reduced and adequately fixed.
Many prosthetic design changes have been introduced in attempt to improve outcomes following TKA; however there is no consensus as to whether these changes confer benefits to patients. This study aimed to assess whether patients treated with a modern implant design had an enhanced patient outcome compared to a traditional model in a double blind randomised controlled trial. 212 consecutive patients were prospectively randomised to receive either a modern (Triathlon) or a traditional (Kinemax) TKA (both Stryker Orthopaedics). 6 surgeons at a single unit performed all procedures in a standardised manner. A single researcher, blinded to implant allocation, performed all assessments. Patients were assessed pre-operatively, and at 6, 26, 52 weeks post-surgery with the Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, goniometry, timed functional assessment, lower limb power (Leg Extensor Power Rig) and pain numerical rating scales (NRS). Change in scores and between group differences were assessed with Two-Way Repeated Measures ANOVAs.Introduction
Methods