Up to date there are only few reports in literature on the long term survival of uncemented stems. As for cemented THA, 10 year survival of at least 90% is required for any THA. We followed the first 354 consecutive implantations of an uncemented, straight femoral stem (CLS, Zimmer Inc, Warsaw, USA) in 326 patients. Mean time of follow-up evaluation was 17 years (range, 15-20 years).Introduction
Materials and methods
There are only a limited number of long term studies of total knee arthroplasty and few with a minimum fifteen year survivorship of a modular fixed bearing posterior cruciate-retaining prosthesis. This consecutive series of 139 total knee arthroplasties (109 patients), using the non-conforming posterior cruciate-retaining Press Fit Condylar (PFC®) system was followed for a minimum of 15 years (range 15.0 to 16.9 years). The patella were resurfaced with an all-polyethylene component in 83% of knees. The tibial component was always cemented, while a porous-coated femoral component was used in 84% of knees. Fifty-nine knees (45 patients) were followed up for a minimum of 15 years. Fifty-seven patients (70 knees) had died and five (8 knees) were too ill to assess. Survivorship of the prosthesis was confirmed for 98.6% of the prosthesis, as only two patients (2 knees) were lost to follow-up. The mean Knee Society Score and Function Score were 96 and 78 respectively. The total incidence of radiolucent lines was 13%, with 2% around the femur, 11% around the tibia, and 0% around the patella. None of these lines were of any clinical relevance. There was no evidence of progressive radiolucent lines or component loosening, and one case of zone 4 femoral osteolysis. There were five re-operations for any indication, of which four were for polyethylene insert wear. There was also one loose cemented femoral component after more than 15 years. The survival without need for revision for any reason was 99% at 10 years and 95.6% (worst-case scenario of 94.2%) at 15 years. This single-surgeon series with a minimum 15 year follow-up shows that the modular fixed bearing posterior cruciate retaining total knee arthroplasty of the PFC system can provide excellent and predictable long term results in tri-compartmental arthritis of the knee.
We reviewed 39 patients with displaced three- and four-part fractures of the humerus. In 21 patients (group A) we had used an anatomical prosthesis for the humeral head and in 18 (group B) an implant designed for fractures. When followed up at a mean of 29.3 months after surgery the overall Constant score was 51.9 points; in group A it was 51.5 and in group B 52.4 points. The subjective satisfaction of the patients was assessed using a numerical rating scale and was similar in both groups. In group A complete healing of the tuberosities was found in 29% and 50% in group B. Partial integration was seen in 29% of group A and in only one patient in group B, while resorption was noted in 43% of group A and 44% of group B. The functional outcome was significantly better in patients with complete or partial healing of the tuberosities (p = 0.022). The specific trauma prosthesis did not lead to better healing of the tuberosities. The difference in clinical outcome obtained by the two designs did not reach statistical significance.
A consecutive series of 139 total knee arthroplasties (109 patients, average age 67 years), using a non-conforming posterior cruciate-retaining prosthesis was followed for 15 years (range, 15.0 to 16.9 years). Forty-five patients (59 knees) were clinically and radiographically evaluated, 57 (70 knees) had died, five patients (8 knees) were too ill to assess, two patients (2 knees) were considered lost to follow-up. Survivorship analysis was performed using worst case scenario analysis and failure defined as re-operation for any reason.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
We have investigated the effect of multisegmental spinal fusion on the long-term functional and radiological outcome in patients with scoliosis. We compared these patients both with those whose spine had not been fused, and with a control group. We studied 68 patients with idiopathic scoliosis (34 operative and 34 non-operative) who had been followed up for a minimum of five years after treatment. They were matched for age (mean 44 years) and Cobb angle (mean 54°) at follow-up. An age- and gender-matched control group of 34 subjects was also recruited. All participants completed a questionnaire to assess spinal function and to grade the severity of back pain using a numerical rating scale. Radiographs of the spine were taken in the patients with scoliosis and lumbar degenerative changes were recorded. The spinal function scores for the patients with scoliosis who had had a fusion were similar to those who had not. Both scoliosis groups, however, had lower scores than the control group (p <
0.001). The frequency and severity of back pain were lower for patients with scoliosis and fusion than for those without, but higher for both scoliosis groups compared with the control group. Radiographs showed similar degenerative changes in both scoliosis groups.