header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange.

We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05.

Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes.

Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 10 - 10
1 Jan 2018
Sheth N Melnic C Brown N Sporer S Paprosky W
Full Access

The treatment of severe acetabular bone loss is challenging, especially in the setting of an associated chronic pelvic discontinuity. There are several available treatment options for chronic pelvic discontinuity, each of which has its own disadvantages. One of the major difficulties with this entity, regardless of the reconstructive technique chosen, is the inability to obtain reproducible healing of the discontinuity. We evaluated the use of acetabular distraction, a technique which achieves peripheral or lateral distraction and central or medial compression across the discontinuity. We recommend acetabular distraction to allow for implantation of a stable construct, achieve biologic fixation and increase the likelihood of discontinuity healing.

In this multi-center trial, 32 patients that underwent acetabular revision for a chronic pelvic discontinuity using acetabular distraction were radiographically evaluated at a minimum of 25 months (range, 25 to 160 months). The study cohort was categorized according to the Paprosky acetabular bone loss classification: seven (22%) type IIC, five (16%) type IIIA, and 20 (62%) type IIIB defects. Fourteen (70%) of the 20 patients with a type IIIB acetabular bone loss pattern required use of augments for acetabular reconstruction.

Of the 32 patients, 1 (3%) patient required a revision for aseptic loosening, 2 (6%) patients had evidence of radiographic loosening but were not revised, and 3 (9%) patients had migration of the acetabular component into a more stable position. Radiographically, 22 (69%) of the cohort demonstrated healing of the discontinuity. The Kaplan-Meier construct survivorship was 83.3% when using aseptic acetabular loosening as an end-point.

During this study, the authors created a new pelvic discontinuity classification based on the type of reconstruction required. The classification mirrors the Paprosky acetabular bone loss classification. A Type I chronic pelvic discontinuity required jumbo cup reconstruction without augments. A type II discontinuity required the use of an augment for an extracavitary defect. A type III discontinuity required an augment for an intracavitary defect.

Type III defects were further subdivided into type IIIA and IIIB discontinuity. Type IIIA discontinuities utilized an augment to reconstruct the anterosuperior and/or posteroinferior column defect for primary stability of the overall construct. Type IIIB discontinuities utilized augments to reconstruct the anterosuperior and/or posteroinferior column defect for primary stability as well as a posterosuperior augment for supplemental fixation. All augments were unitized to the cup with cement. Type IV defects were massive defects that required the use of two orange-slice augments, secured together with screws and placed centrally to restore the defect, and a cup implanted and unitized to the augments with cement.

According to this new classification, the discontinuity reconstructions in our study were classified as follows: 12 (38%) type I, 8 (25%) type II, 6 (19%) type IIIA, 6 (19%) type IIIB, and 0 as type IV. Acetabular distraction technique demonstrates favorable radiographic outcomes with reproducible discontinuity healing in a majority of cases. This alternative technique allows for biologic fixation and intra-operative customization of the construct to be implanted based on the bone loss pattern present following component removal.