We chose unstable extra-capsular hip fractures as our study group
because these types of fractures suffer the largest blood loss.
We hypothesised that tranexamic acid (TXA) would reduce total blood
loss (TBL) in extra-capsular fractures of the hip. A single-centre placebo-controlled double-blinded randomised
clinical trial was performed to test the hypothesis on patients
undergoing surgery for extra-capsular hip fractures. For reasons
outside the control of the investigators, the trial was stopped
before reaching the 120 included patients as planned in the protocol. Aims
Patients and Methods
We implemented an exhaustive operative and supervision algorithm for surgical treatment of hip fractures primarily based on own previously published literature. The purpose was to improve supervision and reduce the rate of reoperations. 2000 consecutive unselected patients above 50 years admitted with a hip fracture were included, 1000 of these prospectively after implementation of the algorithm. Demographic parameters, hospital treatment and reoperations within the first postoperative year were assessed from patient records. The algorithm dictated the surgical treatment based on three objective patient parameters: age, new mobility score and fracture classification on pre-operative anterior-posterior and axial radiographs. Intra capsular fractures were treated with two parallel implants, a sliding hip screw, an arthroplasty or resection of the femoral head. Extra capsular fractures were treated with a sliding hip screw or an intramedullary nail. Supervision of junior registrars was mandatory for the prosthesis and intramedullary nail procedures.Introduction
Materials and methods
During the operative procedure, the lateral femoral wall was fractured in 6% (9/158) of patients, in which an IMHS was performed versus 28% (42/153) operated with a DHS (p<
0.001). Among the DHS, a fractured lateral femoral wall was confirmed to be a predictor of a reoperation (31% (13/42) of patients with a fractured lateral femoral wall versus 8% (9/111) with an intact lateral femoral wall, p<
0.001). As in other studies, the different reoperation rate would have been overseen in the main group of AO/ OTA type 31A1-2 PTF fractures (4% (6/164) IMHS versus 6% (30/471) DHS, p=0.196).
After implementing the guideline, the rate of unsupervised junior registrars performing operations declined from 20% (188/938) to 6% (21/336, p<
0.001 X2). The rate of reoperations declined from 15% (139/938) to 10% (35/336, p=0.044 X2, p=0.043 log.reg.), with a 20% (85/436) to 13% (23/174) decline for intracapsulary and an 11% (54/502) to 7% (12/162) decline for extracapsulary fractures.
Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip. The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (α) angle and the triangular index, a new measure of asphericity of the femoral head. In addition, the α-angle and the triangular index were assessed on the AP and lateral hip radiographs of 82 men and 82 women randomly selected from patients scheduled for total hip replacement (THR). The influence of varying femoral rotation on the α angle and the triangular index was also determined in femoral specimens under experimental conditions. From the 2803 radiographs the mean AP α-angle was 55° (30° to 100°) in men and 45° (34° to 108°) in women. Approximately 6% of men and 2% of women had cam malformation. The α-angle and triangular index were highly inter-related. Of those patients scheduled for THR, 36 men (44%) and 28 women (35%) had cam malformation identifiable on the AP radiographs. The triangular index proved to be more reliable in detecting cam malformation when the hip was held in varying degrees of rotation. The combination of the α-angle and the triangular index will allow examination of historical radiographs for epidemiological purposes in following the natural history of the cam deformity.