Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 155 - 155
1 Sep 2012
Ruggieri P Pala E Mavrogenis AF Romantini M Manfrini M Mercuri M
Full Access

Introduction

Historically, amputation or rotationplasty were the treatment of choice in skeletally immature patients. The introduction of expandable endoprostheses in the late 1980s offered the advantages of limb-salvage and limb length equality at skeletal maturity and a promising alternative with improved cosmetic results and immediate weight bearing.

Objective

to describe the Rizzoli experience in reconstruction with three different types of expandable prostheses in growing children with malignant bone tumors of the femur, assess the outcome of limb salvage in these patients, analyze survival and complications related to these prostheses used over time.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 196 - 196
1 Jun 2012
Ruggieri P Pala E Mercuri M
Full Access

Objective

was to review the experience of the Rizzoli with megaprosthetic reconstruction of the extremities in musculoskeletal oncology.

Material and methods

Between April 1983 and December 2007, 1036 modular uncemented megaprostheses of the lower limbs were implanted in 605 males and 431 females: 160 KMFTR(r), 633 HMRS(r) prostheses, 68 HMRS(r) Rotating Hinge and 175 GMRS(r). Sites: distal femur 659, proximal tibia 198, proximal femur 145, total femur 25, distal femur and proximal tibia 9. Histology showed 612 osteosarcomas, 113 chondrosarcomas, 72 Ewing's sarcoma, 31 metastatic carcinomas, 89 GCT, 36 MFH,68 other diagnoses.

Between 1975 and 2006 at Rizzoli 344 reconstructions of the humerus using prosthetic devices (alone or in association with allografts) were performed: 289 MRS(r), 37 HMRS(r), 2 Osteobridge(r), 4 composite prostheses, 8 Coonrad-Morrey(r), 4 custom made prostheses. Sites of reconstruction were: proximal humerus 311, distal humerus 19, diaphysis 5, total humerus 9. Histology showed 146 osteosarcomas, 56 chondrosarcomas, 23 Ewing's sarcoma, 67 metastatic carcinomas, 14 GCT, 10 MFH, 28 other diagnoses.

Patients were followed periodically in the clinic. Information were obtained from clinical charts and imaging studies with special attention to major complications requiring revision surgery. Major prostheses-related complications were analysed and functional results evaluated according to the MSTS system. Univariate analysis by Kaplan-Meier actuarial curves was used for studying implant survival to major complications.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 197 - 197
1 Jun 2012
Ruggieri P Pala E Mercuri M
Full Access

Objective

of this study was to analyse results of two stage revisions in infected megaprostheses in lower limb.

Material and methods

Between April 1983 and December 2007, 1036 modular uncemented megaprostheses were implanted in 605 males and 431 females with mean age 33.5 yrs: 160 KMFTR(r), 633 HMRS(r) prostheses, 68 HMRS(r) Rotating Hinge and 175 GMRS(r). Sites: distal femur 659, proximal tibia 198, proximal femur 145, total femur 25, distal femur and proximal tibia 9. Histology showed 612 osteosarcomas, 113 chondrosarcomas, 72 Ewing's sarcoma, 31 metastatic carcinomas, 89 GCT, 36 MFH,68 other diagnoses.

Infection occurred in 80 cases (7.7%) at mean time of 4 yrs (min 1 month, max 19 yrs) in 18 KMFTR(r), 47 HMRS(r), 5 HMRS(r) Rotating Hinge, 10 GMRS(r). Sites: 51 distal femurs, 21 proximal tibias, 6 proximal femurs, 1 total femur and 1 extrarticular knee resection. Most frequent bacteria causing infection were: Staphilococcus Epidermidis (39 cases), Staphilococcus Aureus (17) and Pseudomonas Aeruginosa (5). Infection occurred postoperatively within 4 weeks in 9 cases, early (within 6 months) in 12 cases, late (after 6 months) in 59 cases.

Usual surgical treatment was “two stage” (removal of implant, one or more cement spacers with antibiotics, new implant), with antibiotics according with coltures. One stage treatment was used for immediate postoperative infections, only since 1998.

Functional results after treatment of infection were assessed using the MSTS system.


Purpose

of this study is to analyze the results of a modular reconstructive tumor prosthesis for the lower limb (GMRS(r)) with a comparative statistical analysis of primary and secondary implants.

Material and methods

From October 2003 to September 2007 at Rizzoli 161 GMRS(r) prostheses were implanted, most after resection of osteosarcoma (94 cases, 58%). It is a modular system with a rotating hinge mechanism for the knee, cemented and uncemented stems, in titanium and chromium-cobalt-molybdenum, curved and straight-fluted, with or without hydroxyapatite coating. Moreover adaptors are available to revise HMRS(r) implants.

This series includes 88 males and 73 females ranging in age from 9 to 80 years. Sites of reconstruction were 109 distal femurs, 19 proximal femurs, 1 total femur and 32 proximal tibias. There were 149 oncologic and 12 non oncologic diagnoses, including 96 primary reconstructions and 65 revisions after failure of previous implant. A retrospective analysis of imaging and complications was performed and functional results assessed according to MSTS system. Statistical analysis with Kaplan-Meier curves was used to study implant survival.