Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 20 - 20
1 May 2015
Lancaster S Ogunleye O Smith G Clark D Packham I
Full Access

Rupture of the pectoralis major (PM) tendon is a rare yet severe injury. Several techniques have been described for PM fixation including a transosseus technique, when cortical buttons are placed at the superior, middle and inferior PM tendon insertion positions. The concern with this technique is the risk that bicortical drilling poses to the axillary nerve as it courses posteriorly to the humerus.

This cadaveric study investigates the proximity of the posterior branch of the axillary nerve to the drill positions for transosseus PM tendon repair. Drills were placed through the humerus at the superior, middle and inferior insertions of the PM tendon and the distance between these positions and the axillary nerve, which had previously been marked, was measured using computed tomography (CT) imaging.

This investigation demonstrates that the superior border of PM tendon insertion is the fixation position that poses the highest risk of damage to the axillary nerve.

Caution should be used when performing bicortical drilling during cortical button PM tendon repair, especially when drilling at the superior border of the PM insertion. We describe ‘safe’ and ‘danger’ zones for transosseus drilling of the humerus reflecting the risk posed to the axillary nerve.