Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 52 - 52
1 Jan 2016
Takigami I Otsuka H Iwase T Fujita H Akiyama H
Full Access

Background

Impaction bone grafting (IBG) using a circumferential metal mesh is one of the options that allow restoration of the femoral bone stock and stability of the implant in hip arthroplasty. Here we examined the clinical and radiographic outcome of this procedure with a cemented stem and analyzed experimentally the initial stability of mesh–grafted bone–cemented stem complexes.

Methods

We retrospectively reviewed 6 hips (6 patients) that had undergone femoral revisions with a circumferential metal mesh, impacted bone allografts, and a cemented stem. The mean follow-up period was 2.9 years (range, 1.4–3.8 years). Hip joint function was evaluated with the Japanese Orthopaedic Association hip score, and radiographic changes were determined from radiographs. The initial resistance of cemented stem complexes to axial and rotational force was measured in a composite bone model with various segmental losses of the proximal femur.


Purpose

The purpose of this study is to compare using a novel cementing technique with hydroxyapatite granules at bone-cement interface with using the 3rd cementing technique on the acetabular component.

Patients and Methods

Between 2005 and 2007, we performed 54 primary cemented THAs using the 3rd generation cementing technique with hydroxyapatite granules at bone-cement interface (Group A: 21 hips) or without them (Group B: 33 hips) in 49 patients with dysplastic hip (6 males, 43 female; mean age at operation, 67 years; age range, 48–84 years). Mean follow up was 5.3 years (range, 2.3–7.1 years), with none of the patients lost to follow up. According to Crowe's classification, subluxation was Group I in 31 hips, group II in 11 hips, group III in 8 hips, and group IV in 4 hips. We used Exeter flanged cup, Exeter stem with a 22-mm diameter metal head (Stryker, Benoist Girard, France) and Simplex-P bone cement (Stryker, Limerick, Ireland) in all hips. A posterolateral approach was performed for all patients. Bone graft was performed 25 hips (block bone graft: 11 hips; impaction bone grafting with a metal mesh: 13 hips) from autogeneic femoral head. Our 3rd cementing technique is to make multiple 6-mm anchor holes, to clean the the host acetabular bed with pulse lavage, to dry it with hydrogen peroxide and to use Exeter balloon pressurizer and Exeter flanged cup.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 199 - 199
1 Mar 2013
Hirose S Otsuka H Morishima T
Full Access

Introduction

We report our mid-term results and risk factors of a two-stage revision using impaction bone grafting for an infected hip replacement.

Methods

A two-stage revision using impacted cancellous allografs and cement was performed in 13 patients (7 total hip replacements, 6 femoral head replacements) with confirmed infection. The mean age of the patients at first stage operation was 63 years (range, 45–84 years).

In the first stage, local antibiotics were added to customized cement beads and/or a cement spacer after removal of all components and radical debridement. In the second stage, impaction grafting was done using the X-change system (Exeter).