header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 24 - 24
1 Dec 2021
Diniz SE Ribau A Vinha A Guerra D Soares DE Oliveira JC Abreu M Sousa R
Full Access

Aim

Our goal is to assess diagnostic accuracy of synovial fluid testing in diagnosing prosthetic joint infection (PJI) as defined by the European Bone and Joint Infection Society (EBJIS). In addition to differential leukocyte count, simples and inexpensive biomarkers such as synovial fluid C-reactive protein (CRP), adenosine deaminase (ADA) and alpha-2-macrogloblulin(A2M) were also investigated and its possible role in increasing accuracy assessed.

Method

Between January/2013 and December/2019 total hip or knee arthroplasty revision cases (regardless of preoperative diagnosis) were prospectively included provided enough synovial fluid for biomarker analysis was collected and at least four tissue samples, as well as the implant for sonication, were gathered for microbiological study. Definitive diagnosis was classified according to the new EBJIS PJI definition. Using receiver operating characteristic curves, we determined cutoff values as well as diagnostic accuracy for each marker.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 86 - 86
1 Dec 2016
Serrano P Silva MS Dias J Oliveira JC Oliveira A Sousa R
Full Access

Aim

Our goal is to increase diagnostic accuracy of synovial fluid testing in differentiating prosthetic joint infection(PJI) by more exhaustively studying simple and inexpensive biomarkers. For that purpose, we sought to determine: 1) if synovial fluid C-reactive protein(CRP), alpha-2-macrogloblulin(A2M), procalcitonin and adenosine deaminase(ADA) concentrations are different between infected and aseptic cases; 2) performance and optimal cutoff values of each marker; 3) whether any such test may help improve diagnostic performance of traditional leukocyte count.

Method

Between January/2013 and December/2015 total hip or knee arthroplasty revision cases (regardless of preoperative diagnosis) were prospectively included provided enough synovial fluid for biomarker analysis was collected and at least four tissue samples as well as the implant for sonication were gathered for microbiological study. Definitive diagnosis was classified as infection or aseptic on the basis of the recent International Consensus Meeting definition of PJI. Using receiver operating characteristic curves, we determined cutoff values as well as sensitivity and specificity for each marker.