Our goal is to assess diagnostic accuracy of synovial fluid testing in diagnosing prosthetic joint infection (PJI) as defined by the European Bone and Joint Infection Society (EBJIS). In addition to differential leukocyte count, simples and inexpensive biomarkers such as synovial fluid C-reactive protein (CRP), adenosine deaminase (ADA) and alpha-2-macrogloblulin(A2M) were also investigated and its possible role in increasing accuracy assessed. Between January/2013 and December/2019 total hip or knee arthroplasty revision cases (regardless of preoperative diagnosis) were prospectively included provided enough synovial fluid for biomarker analysis was collected and at least four tissue samples, as well as the implant for sonication, were gathered for microbiological study. Definitive diagnosis was classified according to the new EBJIS PJI definition. Using receiver operating characteristic curves, we determined cutoff values as well as diagnostic accuracy for each marker.Aim
Method
The aims of this study were to increase the diagnostic accuracy
of the analysis of synovial fluid in the differentiation of prosthetic
joint infection (PJI) by the addition of inexpensive biomarkers
such as the levels of C-reactive protein (CRP), adenosine deaminase
(ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Between January 2013 and December 2015, synovial fluid and removed
implants were requested from 143 revision total joint arthroplasties.
A total of 55 patients met inclusion criteria of the receipt of
sufficient synovial fluid, tissue samples and removed implants for
analysis. The diagnosis of PJI followed the definition from a recent International
Consensus Meeting to create two groups of patients; septic and aseptic.
Using receiver operating characteristic curves we determined the
cutoff values and diagnostic accuracy for each marker.Aims
Patients and Methods
Our goal is to increase diagnostic accuracy of synovial fluid testing in differentiating prosthetic joint infection(PJI) by more exhaustively studying simple and inexpensive biomarkers. For that purpose, we sought to determine: 1) if synovial fluid C-reactive protein(CRP), alpha-2-macrogloblulin(A2M), procalcitonin and adenosine deaminase(ADA) concentrations are different between infected and aseptic cases; 2) performance and optimal cutoff values of each marker; 3) whether any such test may help improve diagnostic performance of traditional leukocyte count. Between January/2013 and December/2015 total hip or knee arthroplasty revision cases (regardless of preoperative diagnosis) were prospectively included provided enough synovial fluid for biomarker analysis was collected and at least four tissue samples as well as the implant for sonication were gathered for microbiological study. Definitive diagnosis was classified as infection or aseptic on the basis of the recent International Consensus Meeting definition of PJI. Using receiver operating characteristic curves, we determined cutoff values as well as sensitivity and specificity for each marker.Aim
Method
1. In the treatment of chronic osteomyelitis the most troublesome factor is the infected bone cavity. This is seldom obliterated spontaneously by bone regeneration. The number of procedures designed to fill the cavity, since the beginning of the century, show how much it troubles the surgeon. 2. The use of bone grafts in the treatment of chronic osteomyelitis has been studied. One hundred and twenty cases are reviewed (the largest series in the literature), the follow-up being between two and ten years. The most common lesion was a bone cavity, with or without a sequestrum. 3. Treatment must include the removal of infected soft tissues as well as sclerosed bone, and must be done under appropriate antibiotic control. The value of cancellous bone grafts in filling infected cavities in the metaphysio-epiphysial regions is especially emphasised. 4. The results were gratifying, only four relapses occurring in 120 cases.