Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims

The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years.

Methods

From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1646 - 1647
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 147 - 153
1 Feb 2019
Mai DH Oh C Doany ME Rokito AS Kwon YW Zuckerman JD Virk MS

Aims

The aim of this study was to investigate the effects of preoperative bisphosphonate treatment on the intra- and postoperative outcomes of arthroplasty of the shoulder. The hypothesis was that previous bisphosphonate treatment would adversely affect both intra- and postoperative outcomes.

Patients and Methods

A retrospective cohort study was conducted involving patients undergoing arthroplasty of the shoulder, at a single institution. Two patients with no previous bisphosphonate treatment were matched to each patient who had received this treatment preoperatively by gender, age, race, ethnicity, body mass index (BMI), and type of arthroplasty. Previous bisphosphonate treatment was defined as treatment occurring during the three-year period before the arthroplasty. The primary outcome measure was the incidence of intraoperative complications and those occurring at one and two years postoperatively. A total of 87 patients were included: 29 in the bisphosphonates-exposed (BP+) group and 58 in the non-exposed (BP-) group. In the BP+ group, there were 26 female and three male patients, with a mean age of 71.4 years (51 to 87). In the BP- group, there were 52 female and six male patients, with a mean age of 72.1 years (53 to 88).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 76 - 76
1 Mar 2017
Walker P Meere P Salvadore G Oh C Chu L
Full Access

INTRODUCTION

Ligament balancing aims to equalize lateral and medial gaps or tensions for optimal functional outcomes. Balancing can now be measured as lateral and medial contact forces during flexion (Roche 2014). Several studies found improved functional outcomes with balancing (Unitt 2008; Gustke 2014a; Gustke 2014b) although another study found only weak correlations (Meneghini 2016). Questions remain on study design, optimal lateral-medial force ratio, and remodeling over time. Our goals were to determine the functional outcomes between pre-op and 6 months post-op, and determine if there was a range of balancing parameters which gave the highest scores.

METHODS

This IRB study involved a single surgeon and the same CR implant (Triathlon). Fifty patients were enrolled age 50–90 years. A navigation system was used for alignments. Balancing aimed for equal lateral and medial contact forces throughout flexion, using various soft tissue releases (Meneghini 2013; Mihalko 2015). The patients completed a Knee Society evaluation pre-op, 4 weeks, 3 months and 6 months. The total (medial+lateral) force, and the medial/(medial+lateral) force ratio was calculated for 4 flexion angles and averaged. These were plotted against Pain, Satisfaction, Delta Function (postop – preop), and Delta Flexion Angle. The data was divided into 2 groups. 1. By balancing parameters. T-Test for differences in outcomes between the 2 groups. 2. By outcome parameters. T-Test for differences in Balancing Parameters between the two groups.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects.

A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed.

The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result.

With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects.

Cite this article: Bone Joint J 2013;95-B:1667–72.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 63 - 63
1 Apr 2013
Kim J Oh C Oh JK Lee HJ
Full Access

Background

Although gradual bone transport may provide a large-diameter bone, complications are common with the long duration of external fixation. To reduce such complications, a new technique of bone transport with a locking plate has been done for tibial bone defect.

Methods

In 13 patients (mean age, 38.9 years) of chronic osteomyelitis or traumatic bone defect, segmental transport was done using external fixator with a locking plate. In surgical technique, a locking plate was fixed submuscularly, holding the proximal and distal segments. Then, the external fixator for transport was fixed without contact of the locking plate. After docking, 2 or 3 screws were fixed at the transported segment through the plate holes. At the same time, the external fixator was removed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 22 - 22
1 Sep 2012
Rumble T Bartolini A Oh C
Full Access

Abstract

By next summer the number of patients in the tranexamic acid group will be much higher, probably around 50–60.

Purpose

Tranexamic acid has been extensively studied in single total knee and total hip replacement patients. It has been found to reduce blood loss and transfusion rates, with no increase in the rate of venous thromboembolism.

This study was undertaken to determine whether tranexamic acid reduces blood loss and the rate of blood transfusion after bilateral total knee replacement, which has a much higher transfusion rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 937 - 941
1 Jul 2011
Bae J Oh J Chon C Oh C Hwang J Yoon Y

We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared.

The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group.

We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 122 - 122
1 Mar 2010
Oh J Oh C Kim S Jo K Bin S Yoon J
Full Access

We evaluated the outcome of hemiarthroplasty with bone block graft and low profile prosthesis (Aequalis® fracture prosthesis) for the comminuted proximal humerus fractures. Sixteen low profile prostheses were used since July 2004, and 11 patients were followed-up for average 19.9 (12–30) months. Their mean age was 67.3 (52–78) years. Cemented stem in all cases. Two bone block graft and cancellous chip bone from resected humeral head. Ten cases for Neer type 4 fracture, one case for type 3 fracture. During 6 weeks, abduction brace with neutral rotation position was maintained. Passive and active range of motion exercise started at 6 weeks. Pain and satisfaction visual analog scale (VAS), range of motion, and modified UCLA score for hemiarthroplasty were evaluated at every visit. Radiography was also checked for stem position, loosening, and tuberosity union.

Mean pain VAS was 2.7 (0–5), and mean satisfaction VAS was 8.4 (5–10). Mean active forward flexion was 137o (90–170), external rotation at side was 45.5o (25–70), and internal rotation at back was T10 (T7-L1). Modified UCLA score was 19 (12–30) at final visit. All stems were stable, and there were no loosening at the final follow-up. All tuberosities were united except two tuberosity absorptions. One complication case was infection.

The outcome of hemiarthroplasty with bone block graft and low profile prosthesis was comparable to other implants for comminuted proximal humerus fractures. This system had unique advantages for tuberosity union. Further study with more patients and longer follow-up period are necessary to clarify the effectiveness of this prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications.

Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 335 - 335
1 Mar 2004
Kim S Kim S Oh C Lee S Park I Ihn J
Full Access

Aims: To evaluate the early midterm outcomes of primary total hip arthroplasty (THA) using Hydroxyapatite (HA)-coated on smooth surface acetabular component with 28 mm metal head on polyethylene liner articulation. Methods: Seventy primary THA in 63 patients with HA-coated acetabular component were performed consecutively between June 1993 and August 1996. Fifty-four cases were eligible for follow-up of average 71 months (48–104) and the mean age of index operation was 49 years (23–71). The clinical results were analyzed by modiþed Harris hip score, and the radiologic evaluation in terms of stability, polyethylene wear rate (Dorr method), osteolysis around acetabular component was done. Results: Mean Harris hip score improved from 50.9 to 82.2 at the last follow-up. Excellent or good results were found in 38 cases (70%). Eight cases (15%) were unstable radiologically. Pelvic osteolysis was found at 18 cases (33%). The mean polyethylene wear rate was 0.146 mm/year (0.01–0.45). Wear rate of hip dyaplasia was greater than osteonecrosis signiþcantly (p< 0.05). Seven cases (13%) were revised (5 mechanical failures, 2 deep infections). Any bone ongrowth was not found during revision surgery for loose components. Complications included 5 heterotrophic ossiþcations, 2 deep infections, and 1 nonrecurrent dislocation. Conclusion: Primary THA using HA-coated on smooth surface acetabular component showed unsatisfactory clinical results, accelerated polyethylene wear rate accompanying high incidence of osteolysis, and high loosening rate due to lack of bony ongrowth at early midterm.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 208 - 208
1 Nov 2002
Oh C Ihn J Park B
Full Access

Introduction: This study was designed to investigate the feasibility and advantages of minimally invasive plate osteosynthesis of tibia fractures.

Methods: In a prospective study, 24 cases of unstable tibial fractures were stabilized with a narrow LC-DCP (Limited Contact-Dynamic Compression Plate) inserted using minimally invasive percutaneous plate osteosyn-thesis technique. The technique consisted of 3 major steps: 1) reduction of fracture with or without distractor; 2) pre-contoured plate insertion percutaneously at the stab incision distant to fracture site; 3) plate fixation to the tibia percutaneously inserted screw. All the procedure was done under fluoroscopic guide. Between January 1998 and March 1999, we operated 16 proximal or distal periarticular fractures, 5 segmental fractures, and 3 mid-shaft fractures of adolescents that had still open physis. 18 fractures were closed, and 4 were open.

Results: 22 of 24 cases healed without second procedures such as bone graft or correction of angular deformity. There was no infection except 1 case of superficial infection that was healed with early removal of plate. There were 3 cases of screw breakage, but no procedure was required. At the follow-up, 2 patients were healed with > 5 degree varus alignment and > 10 degree internal rotation. All the patients had good knee or ankle function.

Conclusion: The authors feel confident that the minimally invasive technique for plate osteosynthesis of tibial fractures that would be inappropriate for intramedullary nailing will prove to a feasible and worthwhile method of stabilization, while avoiding the severe complications associated with the other methods.