Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 46 - 46
23 Feb 2023
Morris H Cameron C Vanderboor T Nguyen A Londahl M Chong Y Navarre P
Full Access

Fractures of the neck of femur are common in the older adult with significant morbidity and mortality rates. This patient cohort is associated with frailty and multiple complex medical and social needs requiring a multidisciplinary team to provide optimal care. The aim of this study was to assess the outcomes at 5 years following implementation of a collaborative service between the Orthopaedic and Geriatric departments of Southland Hospital in 2012.

Retrospective data was collected for patients aged 65 years and older who were admitted with a fragility hip fracture. Data was collated for 2011 (pre-implementation) and 2017 (post-implementation). Demographics and ASA scores were recorded. We assessed 30-day and 1-year mortality, surgical data, length of stay and complications.

There were 74 patient admissions in 2011 and 107 in 2017. Mean age at surgery was 84.2 years in 2011 and 82.6 years in 2017 (p>0.05). Between the 2011 and 2017 groups there has been a non-significant reduction in length of stay on the orthopaedic ward (9.8 days vs 7.5 days, p=0.138) but a significant reduction in length of stay on the rehabilitation ward (19.9 vs 9 days, p<0.001). There was a significant decrease in frequency of patients with a complication (71.6% vs 57%, p=0.045) and a marginal reduction in number of complications (p=0.057). Through logistic regression controlling for age, sex and ASA score, there was a reduction in the odds of having a complication by 12% between 2011 and 2017 (p<0.001). There was no difference in mortality between the groups.

The orthogeriatric model of care at Southland Hospital appears to have reduced both the frequency of complications and length of stay on the rehabilitation ward 5 years after its implementation. This is the first study in New Zealand demonstrating medium-term post-implementation follow-up of what is currently a nationally accepted standard model of care.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 72 - 72
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation.

Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure.

Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue.

The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing.

Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots.

The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot.

The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05.

The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue.

The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 66 - 66
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation.

Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure.

Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue.

The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing.

Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots.

The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot.

The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05.

The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue.

The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 145 - 145
1 May 2012
Nguyen A Ling J Gomez B Cabot J Sutherland L Cundy P
Full Access

Slipped Capital Femoral Epiphysis (SCFE) is a common paediatric disorder with documented racial predilection. No data exists regarding the Australian indigenous and Australian non-indigenous populations. This study provides a comprehensive demographic and epidemiologic analysis of SCFE in South Australia, with emphasis on establishing associations between increasing obesity and incidence.

A demographic review of all cases of SCFE managed in South Australian public hospitals between 1988 and 2007 was performed. Clinical presentation, surgical management and complication profile information was collected. Given that obesity is implicated in the biomechanical causation of SCFE due to increased shearing forces, particular emphasis was placed on gathering weight, race, gender and age data. A profile of the incidence and nature of SCFE was generated. Comparisons were then drawn between this profile and existing epidemiologic percentile data of weight, age and gender in South Australia.

A rising prevalence of obesity in South Australia corresponded with a rising incidence of SCFE. However, this relationship was not linear as the incidence of SCFE has doubled in the last 20 years and the average weight of SCFE patients has increased markedly.

The indigenous population was found to have higher rates of obesity than the non- indigenous population in South Australia. The indigenous population also has a relative risk of developing a SCFE of over three times the non-indigenous population.

The overall rate of complications in South Australian public hospitals was low, with avascular necrosis being recognised in our profile.

The rise in incidence of SCFE in South Australia; especially noticeable in the indigenous population is associated with an increasing prevalence of obesity. The considerable morbidity associated with SCFE was confirmed in our analysis and further highlights the importance of public health initiatives to tackle obesity in our community.