Single surgeon prospective cohort with radiological follow-up. Anjarwalla et al. have shown that the addition of posterior pedicle supplementation without posterolateral fusion during an ALIF procedure significantly increases the rate of interbody fusion when using a carbon fibre / PEEK cage packed with autogenous iliac crest graft. Stand alone ALIF cages which utilise screws passing through the interbody cage and into the vertebral bodies were designed to obviate the need for a posterior procedure by increasing the anterior construct stability and fusion rate.Study Design
Background
The purpose of this cohort study is to determine the incidence of all congenital vertebral anomalies detected antenatally through ultrasound. We also reported on the early mortality rate for this patient cohort, as well as the frequency and type of associated congenital anomalies. The East Midlands and South Yorkshire Anomalies Register consists of data on all voluntary reports of congenital anomalies, from an annual baseline birth rate of 67000 births. We analysed all registered congenital anomalies reported over a 10 year period. Between January 1997 and January 2007, 108 vertebral anomalies were reported, excluding spinal dysraphism (incidence 0.01%). 61 of these were detected antenatally (56%), 17 were detected postnatally (16%) and in 30 patients, the precise time of diagnosis was unclear (28%). At the time of analysis January 2007, 45 of 108 patients had died, either in utero or soon after delivery (42%). 12 fetuses remained in utero and 51 infants were alive. The mortality rate for antenatally diagnosed patients was 41% and the majority were electively terminated (72%). 2 fetuses electively terminated had vertebral anomalies in isolation. There is a relatively high incidence of elective termination of pregnancy as a result of antenatal anomaly ultrasound screening. We have evidence to suggest that foetuses with potentially minor congenital anomalies are being electively terminated at approximately 18 weeks gestation. A structured and timely spinal counselling should be offered once antenatal vertebral anomalies have been identified.
The purpose of this study was to ascertain whether early diagnosis through antenatal ultrasound screening and intervention lead to a reduction in morbidity associated with congenital scoliosis. Prospective cohort study All fetuses with vertebral body anomalies detected over a thirteen years period were included. Maternal risk factors, accuracy of antenatal diagnosis, associated fetal anomalies and ultimate outcome are described. Twenty-four fetuses with congenital hemivertebrae were identified from 39,000 antenatal scans (incidence 0.061%). The mothers' median age at conception was 26 years (range 18-40 years). The median fetal gestational age at diagnosis was 20 weeks (range 18-38 weeks). The median gestational age at delivery was 38 weeks (range 27-40). Antenatal ultrasound identified eighteen fetuses with a single hemivertebra, six fetuses with multiple hemivertebrae. Eleven patients (50%) have undergone early surgical intervention with median post-natal follow up was 4 years (range 0-9 years). The median age at surgery was 12 months (range 1.2 - 47 months). The median pre-operative Cobb angle was 33 degrees and the median Cobb angle at final follow up was 25 degrees. In this series 50% of patients required surgical intervention. We felt that pre-natal diagnosis of congenital vertebra abnormally has resulted in early surgical intervention using less complex surgical technique to halt progressive deformity. However, further studies are required to compare the results with the abnormally not detected antenatally.